4
F3SG-4RA
□□□□
-25-02TS
Quick Installation Manual
5.Wiring Examples
For input/output circuit and other examples than below, refer to the user's manual.
5-1. EDM used and External Test in 24V Active not used
5-2. Reduced Wiring Connector used and External Test in 24V Active not
used
The F3SG-R meets IP67 (IEC 60529) when it is correctly connected with the Cable for Reduced Wiring (F39-JD
□
BA) and
Reduced Wiring Connector (F39-CN5). Keep the F3SG-R from cutting oils when using these cables and connector.
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
M: 3-phase motor
+24 VDC (Brown)
Not used (Yellow) *3
TEST (Black) *1
Not used (White) *3
Not used (Red) *3
Not used (Pink)
Not used (Gray)
0 VDC (Blue)
OSSD 1 (Black)
OSSD 2 (White)
+24 VDC (Brown)
0 VDC (Blue)
AUX (Yellow)
PC COM (-) (Pink)
PC COM (+) (Gray)
EDM (Red) *2
F39-JD
□□
A-L
*4
F39-JD
□□
A-D *4
KM1
KM2
M
KM1 KM2
KM1
KM2
Power Supply
+24 VDC
0 VDC
Receiver
Emitter
*1. Connect the line to 24 V via a test switch (N.O. contact) if External Test is used.
*2. Connect a lockout reset switch (N.C. contact) to this line in series with the KM1 and KM2 if Lockout Reset is used.
*3. The F39-JD
□
RA-L Single-Ended Cable for Emitter (Oil-Resistant Cable) does not have the red, white and yellow wires.
*4. For the F39-JD
□
A-
□
Single-Ended Cable, connect the shield line to 0 V.
[Settings]
Function
Receiver EDM
Emitter
External Test: 24 V Active (End Cap:
Black) (factory default setting)
F39-JD
□
B-L
F39-CN5
F39-JD
□
A-D *2
KM1
KM2
M
+24 VDC
0 VDC
Power Supply
+24 VDC (Brown)
TEST (Red) *1
OSSD 1 (Black)
OSSD 2 (White)
Not Used (Yellow)
COM(+) (Gray)
COM(-) (Pink)
0 VDC (Blue)
KM1 KM2
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
M: 3-phase motor
Emitter
Receiver
*1. Connect the line to 24 V via a test switch (N.O. contact) if External Test is used.
*2. For the F39-JD
□
A-
□
Single-Ended Cable, connect the shield line to 0 V.
[Settings]
Function
Emitter
External Test: 24 V Active (End Cap:
Black) (factory default setting)
The reduced wiring system can be achieved by using the Reduced Wiring Cables (F39-JD□BA) and the Reduced Wiring Connector
(F39-CN5).
Mounting/Beam Alignment
Wiring
Setting
Operation check