42
Understanding Setting Operations
Section 2-3
2-3-5-3
Adjusting Measurement Time
The processing speed can be adjusted if the measurement time is too long
and the line speed too slow.
1.
Press the SHIFT + Right Keys in Monitor Mode.
The screen for selecting the type of adjustment will be displayed.
2.
Select Time.
The Measurement Time Settings Screen will be displayed.
3.
Use the Left/Right Keys to adjust the time.
Up/Down Keys: Move the cursor between Time and End.
4.
Use the Down Key to select End and press the ENT Key.
A confirmation message will be displayed.
5.
Select OK.
The settings will be registered and the screen in (1.) will return.
0.Scn 0
MON
OK 63ms
S+ENT:Help S+
→
:Adjust
S+ESC:Set disp
STEP/TRG:Msr S+
↑
↓
:Mem img
Freeze
OK
1-OK
2-OK
Judgement method
Time
What do you want to change?
Time
8
Short
Long
End
0.Scn 0
MON
63ms
OK
The judgement results will
change if the measurement
time is changed.
Check the results.