background image

 

INTRODUCTION

Thank you for purchasing the OMRON BP7000 Blood Pressure Monitor.

Your new blood pressure monitor uses the oscillometric method of blood pressure 

measurement. This means the monitor detects your blood movement through your 

brachial artery and converts the movements into a digital reading. An oscillometric 

monitor does not need a stethoscope so the monitor is simple to use.

TABLE OF CONTENTS

INTENDED USE
IMPORTANT SAFETY INFORMATION
1. KNOW YOUR MONITOR
2. PREPARATION
3. USING THE MONITOR WITHOUT A SMART DEVICE
4. USING THE MONITOR WITH A SMART DEVICE
5. ERROR MESSAGES AND TROUBLESHOOTING
6. MAINTENANCE, STORAGE AND CLEANING
7. DISPOSAL
8. SPECIFICATIONS
9. SYMBOL DESCRIPTIONS / DEFINITIONS
10. FCC STATEMENT
11. LIMITED WARRANTY
12. GUIDANCE AND MANUFACTURER'S DECLARATION

INTENDED USE

This device is a digital monitor intended for use in measuring blood pressure and 

pulse rate in adult patient population with arm circumference ranging from 9 

inches to 17 inches (22 cm to 42 cm). The device detects the appearance of 

irregular heartbeats during measurement and gives a warning signal with 

readings.

IMPORTANT SAFETY INFORMATION

Please read the Important Safety Information in this instruction manual 

before using the unit.

Please follow this instruction manual thoroughly for your safety.

Please keep for future reference. For specific information about your own blood 

pressure, CONSULT YOUR PHYSICIAN.

Contraindications

• The device is contraindicated for use in ambulatory environments.

• The device is contraindicated for use on aircraft.

Warning

Indicates a potentially hazardous situation 

which, if not avoided, could result in death or 

serious injury.

• DO NOT adjust medication based on measurement results from this blood 

pressure monitor. Take medication as prescribed by your physician. Only a 

physician is qualified to diagnose and treat high blood pressure.

• DO NOT use this monitor on an injured arm or an arm under medical 

treatment.

• DO NOT wear the arm cuff on your arm while on an intravenous drip or blood 

transfusion.

• DO NOT apply or inflate the arm cuff around any body parts other than your 

upper arm.

• DO NOT use this monitor in areas containing high frequency (HF) surgical 

equipment, magnetic resonance imaging (MRI) equipment, computerized 

tomography (CT) scanners or in oxygen rich environments.

• DO NOT use this monitor on infants, toddlers, children or persons who cannot 

express themselves.

• Consult your physician before using this monitor if you have common 

arrhythmias such as atrial or ventricular premature beats or atrial fibrillation; 

arterial sclerosis; poor perfusion; diabetes; pregnancy; pre-eclampsia; or renal 

disease. Note that any of these conditions in addition to patient motion, 

trembling, or shivering may affect the measurement reading.

• Always consult your physician. Self-diagnosis of measurement results and 

self-treatment are dangerous.

• Contains small parts that may cause a choking hazard if swallowed by children, 

toddlers or infants.

• Keep the BATTERY out of the reach of children, toddlers and infants.

• This product emits radio frequencies (RF) in the 2.4 GHz band. DO NOT use 

this product in locations where RF is restricted, such as on an aircraft or in 

hospitals. For further information on any potential restrictions refer to 

documentation on 

Bluetooth

®

 usage by the FCC.

Caution

Indicates a potentially hazardous situation 

which, if not avoided, may result in minor or 

moderate injury to the user or patient or 

damage to the equipment or other property.

• Stop using this monitor and consult your physician if you experience skin 

irritation or discomfort.

• Consult your physician before using this monitor on an arm with an 

arterio-venous (A-V) shunt.

• Consult your physician before using this monitor if you have had a mastectomy.

• Consult your physician before using the monitor if you have severe blood flow 

problems or blood disorders as cuff inflation can cause bruising.

• Do not take measurements more often than necessary because bruising, due 

to blood flow interference, may occur.

• Remove the arm cuff if it does not start deflating during the measurement.

• Do not use this monitor for any purpose other than measuring blood pressure.

• Do not use a mobile phone or other electrical devices that emit electromagnetic 

fields near this monitor except when transferring your readings to your smart 

device. This may result in incorrect operation of this monitor.

• Do not disassemble or attempt to repair the monitor or components. This may 

cause an inaccurate reading.

• Do not use in a location where there is moisture or a risk of water splashing the 

monitor. This may damage the monitor.

• Do not use this monitor in a moving vehicle such as in a car.

• Do not drop, or subject this monitor to strong shocks or vibrations.

• Do not use this monitor in places with high or low humidity or high or low 

temperatures. See the “8. SPECIFICATIONS” section of the manual.

• Please check, by observation of the arm being used, that the monitor is not 

causing any impairment of patient blood circulation.

• Do not use this monitor in high-use environments such as medical clinics or 

physician offices.

• Avoid bathing, drinking alcohol or caffeine, smoking, exercising and eating for 

30 minutes before taking a measurement.

• Rest for at least 5 minutes before taking the measurement.

• Remove tight-fitting or thick clothing from your arm while taking a measurement.

• Remain still and do not talk while taking a measurement.

Data Transmission

• Do not replace the battery while your reading is being transferred to your smart 

device. This may result in the incorrect operation of your monitor and failure to 

transfer your blood pressure data.

• Do not place integrated circuit cards, magnets, metal objects, or other devices 

that emit electromagnetic fields near this monitor while your reading is being 

transferred to your smart device. This may result in the incorrect operation of 

your monitor and failure to transfer your blood pressure data.

Battery Handling and Usage

• Do not insert the batteries with their polarities incorrectly aligned.

• Use only 4 “AAA” alkaline batteries with this monitor. Do not use other types of 

batteries. Do not use new and used batteries together.

• Remove the batteries if the monitor will not be used for a long period of time.

• If battery fluid should get in your eyes, immediately rinse with plenty of clean 

water. Consult a physician immediately.

• If battery fluid should get on your skin, wash your skin immediately with plenty of 

clean, lukewarm water. If irritation, injury or pain persists, consult a physician.

• Do not use batteries after their expiration date.

• Periodically check your batteries to ensure they are in good working condition.

• Only use batteries specified for this monitor. Use of unsupported batteries may 

damage and/or may be hazardous to the monitor.

1. KNOW YOUR MONITOR

Contents:

Monitor, 4 “AAA” batteries, instruction manual, quick start guide

Monitor:

1.1 Display symbols

Connection symbol ( )

Appears when transferring the data or pairing with your smart device.

Connection OFF symbol ( )

Appears when Bluetooth is off.

Connection ON symbol ( )

Appears when Bluetooth is on.

Movement error symbol ( )

The movement error symbol will display when your body is moving during 

measurement. If the movement symbol displays, remove the monitor and 

wait for 2 to 3 minutes. After 2 to 3 minutes, remain still and take another 

measurement.

SYNC symbol ( )

• When the SYNC symbol appears on the display, make sure that your 

monitor has been pairing with the smart device or transfer the data.

• When the SYNC symbol appears on the display, transfer the data before 

the measurements are deleted. Maximum internal memory is for 100 

measurements. The oldest value will be deleted when this is reached 

before transferring.

Irregular heartbeat symbol ( )

When the monitor detects an irregular rhythm 

two or more times during the measurement, the 

irregular heartbeat symbol will appear on the 
display along with the measurement values. 
An irregular heartbeat rhythm is defined as a 

rhythm that is 25% less or 25% more than the 

average rhythm detected while the monitor is 

measuring the systolic and diastolic blood 

pressure. 

If the irregular heartbeat symbol displays with your measurement results, 

we recommend you consult your physician. Follow the directions of your 

physician.

Battery symbol (low) ( )

Appears when the batteries are low.

Battery symbol (depleted) ( )

Appears when the batteries are depleted.

Deflation symbol ( )

Flashes while arm cuff is deflating.

Heartbeat symbol ( )

Flashes while taking a measurement.

2013 ESH/ESC Guidelines for the management of arterial hypertension

Definitions of hypertension by office and home blood pressure levels

These are from statistical values for blood pressure.

1.2 Before Taking a Measurement

To help ensure an accurate reading, follow these directions:

• Stress raises blood pressure. Avoid taking measurements during 

stressful times.

• Measurements should be taken in a quiet place.

• Keep a record of your blood pressure and pulse readings for your 

physician. A single measurement does not provide an accurate indication 

of your true blood pressure. You need to take and record several 

readings over a period of time. Try to measure your blood pressure at the 

same time each day for consistency.

2. PREPARATION

2.1 Battery Installation

1.

Remove the battery cover.

Insert your fingernail into the slot 

of the battery cover, and push 

downwards to remove the cover.

2.

Insert battery, slide over so it 

is secured inside the circular 

battery positioner. Then 

insert the second battery.

3.

Replace the battery cover.

When the batteries have been securely placed in this monitor, the 
message below will appear on the screen:

Notes:
• When the depleted battery symbol “

” appears on the display, turn the 

monitor off and remove all the batteries. Replace with 4 new batteries at 

the same time. Long life alkaline batteries are recommended.

• The measurement values continue to be stored in the memory even after 

the batteries are replaced.

• The supplied batteries may have a shorter life than new batteries.

• Disposal of used batteries should be carried out in accordance with the 

national/local regulations for the disposal of batteries.

• When the batteries are replaced, the words “Please pair this device.” or 

“Pairing not completed. No data transfer.” will appear on the display. 
Press the [ ] button to pair with the smart device or transfer the data 

before taking a measurement.

2.2 Applying the Arm Cuff

1.

Apply the arm cuff to your left upper 

arm.

The bottom edge of the arm cuff should be 1/2 

inch (1 to 2 cm) above the elbow. The display 

should be in clear view and easy to read, 

positioned slightly on the inside of your arm.

2.

Securely close with the fabric 

fastener.

Notes:
• The blood pressure can differ between 

the right arm and the left arm, and the 

measured blood pressure values can be 

different. Omron recommends to always use the same arm for 

measurement. If the values between both arms differ substantially, please 

check with your physician as to which arm to use for your measurements.

• Positioning the monitor with the [START/STOP] button toward the body 

makes it easier to use the monitor.

2.3 How to Sit Correctly

To take a measurement, you need to be relaxed and 
comfortably seated, at a comfortable room 
temperature. 

• Sit in a chair with your legs uncrossed and your feet flat on 

the floor.

• Sit upright with your back straight.
• Sit with your back and arm being supported.
• The arm cuff should be placed on your arm at the same 

level as your heart.

3. USING THE MONITOR WITHOUT A SMART DEVICE

You can use this blood pressure monitor without pairing to a smart device.

3.1 Taking a Measurement

Notes:
• To stop the measurement, press the [START/STOP] button once to 

deflate the arm cuff.

• Remain still and do not talk while taking a measurement.

• When using this blood pressure monitor without a smart device, you will 

not be able to view your prior readings stored in the memory.

• Do not use the monitor with any other electrical device simultaneously. 

This may result in incorrect operation of the monitor.

1.

Press the [START/STOP] button.

The arm cuff will start to inflate.

The following symbols indicate incorrect measurement

• If “Please remeasure” and any of these symbols below are displayed, 

please take another measurement and try again.

2.

Remove the arm cuff.

3.

Write down your SYS/DIA and Pulse readings, along with 

the date and time of your measurement on a piece of paper 

to keep a record of your history.

4. USING THE MONITOR WITH A SMART DEVICE

4.1 Pairing Your Monitor with a Smart Device

The date and time on your monitor will automatically be set when you pair 
it with your smart device.

1.

Make sure the 

Bluetooth

®

 in your smart device is turned 

on.

2.

Download and install the free “OMRON connect” app on 

your smart device.

* If you already have the “OMRON connect” app, and have created your 

account, visit the “Manage Devices” in the “Profile” section of the 
“OMRON connect” app to add this new device. 

3.

Open the app on your smart device and follow the set-up 

and pairing instructions.

4.

Confirm the monitor is connected successfully.

If the monitor is connected successfully to the smart device, “OK” will 
appear on the display.

If “Error” appears, refer to section 5.1 for more detail.

For more information, visit OmronHealthcare.com
Notes: 
• If you use any other app instead of “OMRON connect”, the date and time 

may not be automatically set.
If you need to set the date and time, pair your monitor or transfer the data 
by using “OMRON connect” app.

• The date/time will only be set for future measurements taken after the 

measurement that was transferred. It will not be saved to the 
measurement that was just transferred.

• Please be aware that OMRON will not be responsible for the loss of data 

and/or information.

4.2 Taking a Measurement

Notes:
• To stop the measurement, press the [START/STOP] button once to 

deflate the arm cuff.

• Remain still and do not talk while taking a measurement.
• This monitor will store 100 measurements. Stored measurements cannot 

be viewed on the monitor's display. You will need to use the “OMRON 
connect” app to view all measurements prior to the most recent reading 
taken.

• Do not use a mobile phone or other electrical devices that emit 

electromagnetic fields near this monitor except when transferring your 
readings to your smart device. This may result in incorrect operation of 
this monitor.

1.

Press the [START/STOP] button.

The arm cuff will start to inflate.

The following symbols indicate incorrect measurement

• If “Please remeasure” and any of these symbols below are displayed, 

please take another measurement and try again.

2.

Remove the arm cuff.

3.

Transfer your readings.

Please make sure your monitor is within 16 ft. (5 m) of your smart device 
and your “OMRON connect” app is active.
As soon as your measurement is complete, tap the “sync” icon in the 
Omron connect app on your smart device to transfer your readings.

Transferring

 your readings later

1. Open the app on your smart device and then follow the instructions.
2. Press [ ] button to transfer your readings.

• If your readings are successfully transferred to your smart device, 

“OK” will flash on the display.

If “Error” appears, refer to section 5.1 for more detail.

Notes:
• When the SYNC symbol “

” appears on the display, transfer the data 

immediately before the readings are deleted.

• When the Connection OFF symbol “

” appears on the display, turn on 

the 

Bluetooth

 feature of your monitor. (Refer to section 4.3)

• Once you send your readings to the app, the data cannot be sent again 

to the app or smart device.

4.

After your readings have been transferred to the “OMRON 

connect” app, press the [START/STOP] button to turn the 

monitor off.

Notes:
• The monitor will automatically turn off after 2 minutes.
• Wait 2-3 minutes before taking another measurement. Waiting between 

measurements allows the arteries to return to the condition they were 
prior to taking the measurement. 

• If you use any other app instead of “OMRON connect”, the data may not 

be displayed correctly after sending.

Data Transfer With Multiple Smart Devices

Once you transfer your data to a smart device, that data can no longer be 
transferred again to the same smart device, nor to another smart device.

About Multiple Users 

To share your blood pressure monitor with other people, please refer to the 
“Help” section in the “OMRON connect” app.

4.3 Turning “OFF” Bluetooth

®

Turn off the 

Bluetooth

®

 in your monitor in the following areas where use 

of wireless equipment is prohibited.
• On aircraft  • In hospitals  • While abroad
Your monitor comes with the 

Bluetooth

®

 already turned on.

1.

Turn your monitor power off if it is on by pressing the 

[START/STOP] button on the monitor.

2.

Press and hold the [ ] button for more than 10 seconds.

Release the [ ] button when “

” appears on the 

display. When the “ ” is blinking, you have now turned the 

Bluetooth

®

 off in your monitor.

 

3.

Press the [START/STOP] button to turn the monitor off.

Note: The monitor will automatically turn off after 2 minutes.

How to turn “ON” Bluetooth

®

Perform the following step when the power has been off.
Press and hold the [ ] button for more than 2 seconds and then 
release the [ ] button when 

 appears on the display.

The 

“ ”

 will blink to show that the 

Bluetooth

®

 in your monitor has 

been turned on.

4.4 Restoring Your Monitor to the Default Settings

To delete all the information stored in your monitor, follow the instructions 
below. Make sure that your monitor is turned off. It will be off when the 
screen is not showing numbers or symbols. 

1.

While holding the [ ] button down, the Connection symbol 

“ ” and “P” appear on the display, and then press the 

[START/STOP] button for more than 5 seconds.

2.

When the “Clear” symbol appears on the display, release 

the [ ] button and [START/STOP] button.

The “Clear” will appear on the display when your monitor settings have 
reverted back to their original.

3.

Press the [START/STOP] button to turn the monitor off.

Notes:
• The monitor will automatically turn off after 2 minutes.
• Reverting to initial settings of this monitor will not delete the information 

in the app.

• When using this monitor again, first delete the registration of monitor in 

the app and then pair your monitor.

EVOLV

TM

Upper Arm

Blood Pressure Monitor

Model BP7000

Instruction Manual

9545343-5C

Connection symbol

Irregular heartbeat symbol

Connection OFF symbol

Battery symbol (low)

Connection ON symbol

Battery symbol (depleted)

Movement error symbol

Deflation symbol

SYNC symbol

Heartbeat symbol
(Flashes during measurement.)

Office

Home

Systolic Blood Pressure

≥140 mmHg

≥135 mmHg

Diastolic Blood Pressure

≥90 mmHg

≥85 mmHg

A

B

C

D

E

A. START/STOP button
B. Connection button
C. Display
D. Arm cuff
E. Battery compartment

F. Systolic blood pressure
G. Diastolic blood pressure
H. Pulse display

G

H

F

Display:

Irregular Heartbeat

Normal Heartbeat

Pulse

Blood pressure

Blood pressure

Short Long

Pulse

Avoid bathing, drinking alcohol or caffeine, smoking, exercising and eating 

for 30 minutes before taking a measurement. 

Rest for at least 5 minutes before taking the measurement.

Remove tight-fitting or thick clothing from your arm while taking a 

measurement. 

1/2 inch
(1 - 2 cm)

START

INFLATING

DEFLATING

COMPLETED

Example:

DO NOT adjust medication based on measurement results from this blood 

pressure monitor. Take medication as prescribed by your physician. Only a 
physician is qualified to diagnose and treat high blood pressure.

Always consult your physician. Self-diagnosis of measurement results and 

self-treatment are dangerous.

Review the list of compatible smart devices at: OmronHealthcare.com

START

INFLATING

DEFLATING

COMPLETED

Example:

®

DO NOT adjust medication based on measurement results from this blood 

pressure monitor. Take medication as prescribed by your physician. Only a 
physician is qualified to diagnose and treat high blood pressure.

Always consult your physician. Self-diagnosis of measurement results and 

self-treatment are dangerous.

HEM-7600T-Z_C_M01_161201.pdf

HEM-7600T-Z_C_M01_161201.fm  1 ページ  2016年12月1日 木曜日 午後5時25分

Summary of Contents for EVOLV BP7000

Page 1: ...e that any of these conditions in addition to patient motion trembling or shivering may affect the measurement reading Always consult your physician Self diagnosis of measurement results and self trea...

Page 2: ...ppears on the display make sure that your monitor has been pairing with the smart device or transfer the data When the SYNC symbol appears on the display transfer the data before the measurements are...

Page 3: ...data before taking a measurement 2 2 Applying the Arm Cuff 1 Apply the arm cuff to your left upper arm The bottom edge of the arm cuff should be 1 2 inch 1 to 2 cm above the elbow The display should...

Page 4: ...ta by using OMRON connect app The date time will only be set for future measurements taken after the measurement that was transferred It will not be saved to the measurement that was just transferred...

Page 5: ...e use of wireless equipment is prohibited On aircraft In hospitals While abroad Your monitor comes with the Bluetooth already turned on 1 Turn your monitor power off if it is on by pressing the START...

Page 6: ...ent during measurement Repeat measurement Remain still and do not talk during measurement Refer to section 4 2 Clothing is interfering with the arm cuff Remove any clothing interfering with the arm cu...

Page 7: ...o 104 F 10 C to 40 C 15 to 90 RH non condensing 800 to 1060 hPa Storage Transport conditions 4 F to 140 F 20 C to 60 C 10 to 90 RH non condensing Weight Monitor Approximately 8 1 2 oz 240 g not includ...

Page 8: ...fic absorption ratio SAR 11 LIMITED WARRANTY Your BP7000 Upper Arm Blood Pressure Monitor excluding batteries is warranted to be free from defects in materials and workmanship appearing within 5 years...

Page 9: ...ecified below The customer or the user of this OMRON battery operated BPM should assure that it is used in such environment Immunity test IEC 60601 test level Compliance level Electromagnetic environm...

Page 10: ...the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in w...

Reviews: