background image

E5CN-HT

Precautions for Safe Use

2152761-5A

Instruction Manual

OMRON CORPORATION

 ©All Rights Reserved

Suitability for Use

CAUTION

CHT1

EN

Safety Precautions

Key to Warning Symbols

Specifications

CAUTION

Warning Symbols

Digital Controller

Thank you for purchasing the OMRON E5CN-HT Digital 
Controller. This manual describes the functions, performance, 
and application methods needed for optimum use of 
the product.
Please observe the following items when using the product.
• This product is designed for use by qualified personnel with   

a knowledge of electrical systems.

• Before using the product, thoroughly read and understand 

this manual to ensure correct use.

• Keep this manual in a safe location so that it is available for 

reference whenever required.

For detailed operating instructions, refer to the 

E5CN-HT/E5AN-HT/E5EN-HT 

Digital Controllers User's Manual 

(Cat. No. H169).

Significance of WARNINGs and CAUTIONs

Indicates a potentially hazardous situation which, if 
not avoided, is likely to result in minor or moderate 
injury or property damage. Read this manual 
carefully before using the product.

Do not touch the terminals while power is being supplied. 
Doing so may occasionally result in minor injury due to electric shock.
Do not allow pieces of metal, wire clippings, or fine metallic shavings or filings from installation to 
enter the product. Doing so may occasionally result in electric shock, fire, or malfunction.
Do not use the product where subject to flammable or explosive gas. Otherwise, minor injury from 
explosion may occasionally occur. 
Never disassemble, modify, or repair the product or touch any of the internal parts. Minor electric 
shock, fire, or malfunction may occasionally occur. 

CAUTION - Risk of Fire and Electric Shock

a) This product is UL listed as Open Type Process Control Equipment. It must be mounted in an enclosure that 

does not allow fire to escape externally.

b) More than one disconnect switch may be required to de-energize the equipment before servicing. 
c) Signal inputs are SELV, limited energy.
d) Caution: To reduce the risk of fire or electric shock, do not interconnect the outputs of different Class 2 circuits.
If the output relays are used past their life expectancy, contact fusing or burning may occasionally occur. Always 
consider the application conditions and use the output relays within their rated load and electrical life expectancy. 
The life expectancy of output relays varies considerably with the output load and switching conditions. 
Tighten the terminal screws to between 0.74 and 0.90 N•m. Loose screws may occasionally result in fire. 
Set the parameters of the product so that they are suitable for the system being controlled. If they are not suitable, 
unexpected operation may occasionally result in property damage or accidents. 
A malfunction in the  Digital Controller may occasionally make control operations impossible or prevent 
alarm outputs, resulting in property damage. To maintain safety in the event of malfunction of the Digital 
Controller, take appropriate safety measures, such as installing a monitoring device on a separate line. 

OMRON shall not be responsible for conformity with any standards, codes, or regulations that 
apply to the combination of the products in the customer's application or use of the product.
Take all necessary steps to determine the suitability of the product for the systems, machines, 
and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE 

OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN 
DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY 
RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT 
OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.

Observe the following precautions to prevent failure to operate, malfunctions, or undesirable effects on 
product performance and functions. Problems may occasionally occur. Do not handle the Controller in ways 
that exceed product specifications. 
(1)  This product is designed for indoor use only. Do not use or store the product in any of the following 

places. 

 

  • Places directly subject to heat radiated from heating equipment. 

 

  • Places subject to splashing liquid or oil atmosphere. 

 

  • Places subject to direct sunlight. 

 

  • Places subject to dust or corrosive gas (in particular, sulfide gas and ammonia gas). 

 

  • Places subject to intense temperature change. 

 

  • Places subject to icing and condensation. 

 

  • Places subject to vibration and large shocks.

(2)  Use/store within the rated temperature and humidity ranges.
       Provide forced-cooling if required.
(3)  To allow heat to escape, do not block the area around the product.
 

Do not block the ventilation holes on the product.

(4)  Be sure to wire properly with correct polarity of terminals.
(5)  Use specified size (M3.5, width 7.2 mm or less) crimped terminals for wiring. To connect bare wires to 

the terminal block, use copper braided or solid wires with a gage of AWG24 to AWG14 (equal to cross- 
sectional area of 0.205 to 2.081 mm2). (The stripping length is 5 to 6 mm.) Up to two wires of same 
size and type, or two crimped terminals can be inserted into a single terminal.

(6)  Do not wire the terminals which are not used.
(7)  Allow as much space as possible between the controller and devices that generate a powerful high- 

frequency or surge.

       Separate the high-voltage or large-current power lines from other lines, and avoid parallel or common 

wiring with the power lines when you are wiring to the terminals.

(8)  Use this product within the rated load and power supply.
(9)  Make sure that the rated voltage is attained within two seconds of turning ON the power using a switch 

or relay contact. If the voltage is applied gradually, the power may not be reset or output malfunctions 
may occur.

(10) Make sure that the Digital Controller has 30 minutes or more to warm up after turning ON the power 

before starting actual control operations to ensure the correct temperature display. 

(11) A switch or circuit breaker should be provided close to this unit.
 

The switch or circuit breaker should be within easy reach of the operator, and must be marked as a 
disconnecting means for this unit.

(12) Always turn OFF the power supply before pulling out the interior of the product, and never touch nor 

apply shock to the terminals or electronic components. When inserting the interior of the product, do 
not allow the electronic components to touch the case. 

(13) Do not use paint thinner or similar chemical to clean with. Use standard grade alcohol. 
(14) Design system (control panel, etc) considering the 2 second of delay that the controller’s output to be 

set after power ON.

(15) The output may turn OFF when shifting to certain levels. Take this into consideration when performing 

control.

(16) The number of non-volatile memory write operations is limited. Therefore, use RAM write mode when 
       frequently overwriting data during communications or other operations. 
(17) Always use suitable tools to dismantle the product for disposal. 
(18) Do not continue to use the product if the front surface peels or becomes cracked. 

Power supply voltage 

100 to 240 VAC, 50/60 Hz or 

 

24 VAC, 50/60 Hz /24 VDC

Operating voltage range 

85 to 110% of the rated voltage

Power consumption                    Approx. 8.5 VA (100 to 240 VAC)
 Approx. 5.5 VA (24 VAC) /
 Approx. 3.5 W (24 VDC)
Indication accuracy 

Thermocouple:

(Ambient temperature: 23°C) 

(±0.1 % of indication value or ±1°C,

 

whichever is greater) ±1 digit max.

  

Platinum resistance thermometer:

 

(±0.1 % of indication value or ±0.5°C,

 

whichever is greater) ±1 digit max.

 

Analog input: ±0.1 % FS ±1 digit max.

Event input 

Output current: approx. 7 mA per contact.

  Contact input 

ON:1 k

Ω

 max., OFF: 100 k

Ω

 min.

  No-contact input 

ON: residual voltage 1.5 V max.,

 

OFF: leakage current 0.1 mA max.

Control output 1 

Relay output  :SPST-NO

 

250VAC, 3A(resistive load)

 

Voltage output (for driving SSR): 

 

12 VDC, 21 mA 

 

Current output: 4 to 20 mADC, 0 to 20 mADC

 

 Load: 

600 

Ω

 max.

 

Linear voltage output   0 to 10 VDC

 

Load: 1 k

Ω

 min.

 

Electrical life of relay: 100,000 operations

 

(Long-life model: 1 million operations)

Control output 2 

Voltage output (for driving SSR): 12 VDC, 21 mA

Control method 

ON/OFF or 2-PID control

Auxiliary outputs 

Relay outputs: 250 VAC, 3 A (resistive load), 

 

Electrical life of relay:

 100,000 

operations

Ambient temperature 

-10 to 55°C

 

(With no condensation or icing)

Ambient humidity 

25 to 85%

Storage temperature 

-25 to 65°C

 

(With no condensation or icing)

Altitude Max. 

2,000m

Recommended fuse 

T2A, 250 VAC, time-lag,

 low-breaking 

capacity

Weight 

Approx. 150 g (main unit only)

Degree of protection 

Front panel: IP66

 

Rear case: IP20, Terminal section: IP00

Installation environment 

Installation category II, pollution

 

degree 2 (as per IEC61010-1)

Memory protection 

Non-volatile memory 

 

(Number of write operations: 1,000,000 

 

at an ambient temperature of 25°C)

Transfer output 

4 to 20 mA DC, Load : 600 

Ω

 

max. 

Operation indicators

.

ni

0

6

45

5

4

+0.6

0

6.

0

+

0

6.

0

+

0

(48 x number of units - 2.5)

+1

0

5

4

Individual mounting (mm) Side-by-side mounting (waterproof not possible) (mm)

Mode key
Press this key to change the 
contents of the display.
Press this key for 1 s or longer 
for reverse scroll.

Terminal 

cover

Watertight

packing 

Adapter

°C / °F : Temperature unit 

The temperature unit is displayed 

when the displayed value is a 

temperature.
When this parameter is set to“°C”, 

C

” is displayed, and when set to 

“°F”, “

F

 ”is displayed.

         :Protection indicator

Lit when Setting Change Protect is
ON (disables the Up and Down Keys). 

MANU: Manual output indicator
Lit when the Auto/Manual Mode is set 

to Manual Mode. 

Level key
Use this key to change levels:

Press the 

O

 key and the 

M

 key

together for at least 3 seconds 
to switch to protect level.

No.1 display
Process value or set data symbol

No.2 display
Set point, set data read-out value or 
changed input value 

Up and Down keys
Use the keys to change the values 
displayed  on the No.2 display.
Each press of 

U

 key increments or advances 

the values displayed on the No.2 display.
Each press of 

D

 key decrements or returns 

the values displayed on the No.2 display.

Dimensions

Names of parts on front panel

Installation

Wiring

Connections

(The applicability of the electric terminals varies with the type of machine.)

58

6

44.8 

×

 44.8

48.8

1.5

78

91

Dimensions (mm)

•  A heater burnout alarm, heater short alarm, heater overcurrent alarm, or input alarm is output to the output to which the alarm 1 function is assigned.
•  The voltage output (control output) is not electrically insulated from the internal wiring. When using a grounded thermocouple thermometer, one or the other 

of the control output terminals must not be grounded. (If both terminals are grounded, measurements will be unreliable due to sneak current.) 

•  The last character of the lot number “R” indicates that reinforced insulation is provided between input power supply, relay outputs, and between other 

terminals.  

Conformance to EN/IEC Standards

This is a class A product. 
In residential areas it may cause radio 
interference, in which case the user may 
be required to take adequate measures 
to reduce interference.

Conformance to Safety Standards

Reinforced insulation is 
provided between input power 
supply, relay outputs, and 
between other terminals.

In the pack:  

*Main unit  
*Watertight packing  
*Adapter  
*Instruction manual  
*Terminal cover (Provided only for models with “-500”

      suffix only)

Solderless terminal size: M3.5
Terminal cover: E53-COV17
USB-Serial Conversion Cable 
(Sold Separately)(E58-CIFQ1)

* The main unit can be removed for maintenance without disconnecting the terminal  wiring.

* Do not remove the terminal block. Doing so may result in failure or malfunction.

* A Setup Tool port is provided on the bottom of the product. Use this port to connect a personal computer to the 

product when using the Setup Tool. E58-CIFQ1 USB-Serial Conversion Cable is required to connect the personal  

computer to the product. (Do not use the product with the USB-Serial Conversion Cable left permanently connected.)

Refer to the instruction manual provided with the USB-Serial Conversion Cable for details on connection methods. 

When waterproofing is required, be sure to mount the 
controller separately. 
Attach the waterproof packing from the terminal side and 
then insert the controller to the panel. Recommended panel 
thickness is 1 to 5 mm.

•  Insert the controller through the hole in the panel. Push the adapter on from the rear and 

fasten temporarily, removing any gap between the controller, panel and adapter. Finally, 
secure two fixing screws alternately keeping the torque to between 0.29 to 0.39  N•m.  

•  Make sure that the surrounding temperature does not exceed the allowable operating 

temperature given in the specifications especially when two or more controllers are 
mounted.

+

A

B

B

+

+

V

trol output

C

Control outpu

1

• 100-240V AC Type

• 24V AC/DC Type (no polarity)

DO NOT

USE

+

mA

DO NOT
USE

DO NOT
USE

11

12

13

14

15

B(+)

A(

)

RS-485

DO NOT USE

+

-

11

12

13

14

15

DO NOT
USE

+

-

+

-

11

12

13

14

15

EV1

EV2

+

-

11

12

13

14

15

CT2

CT1

B(+)

A(

)

RS-485

11

12

13

14

15

CT2

CT1

+

-

11

12

13

14

15

EV1

EV2

+

-

11

12

13

14

15

RS-232C

SD

RD

SG

CT1

The E5

@

N-HT is set for a K thermocouple (input type of 5) by 

default. If a different sensor is used, an input error (

s.err

) will 

occur. Check the setting of the Input Type parameter.

Auxiliary output

(Relay outputs)

Auxiliary output 2

Auxiliary output 

(Relay outputs)

250 VAC 3A 
(resistive load)

Communications

(RS-485) 

and

control output 2

(

)

Control output 2 and
transfer output

Event inputs and

Communications
(RS-485) 

and

2 CTs

(

Control output 2

and 2 CTs  

Event inputs and

control output 2 

pp

Communications
(RS-232C) 

and CT

transfer output

Transfer

 output

Control output 2

rol output 

12VDC,21 mA

A

DC,21 m

ppp

Control output 2

rol output 

 12VDC,21 mA

A

DC,21 m

ppp

Control output 2

ol output 2

12VDC,21 mA

DC,21 mA

ppp

(Load: 600 

Ω

 max.)

4-20 mADC

Control output 2

ol output 2

 12VDC,21 mA

DC,21 m

ppp

(Load: 600 

Ω

 max.)

4-20 mADC

Transfer

 output

Relay output
250VAC 3A

 (resistive load)

Voltage output

(for driving SSR)

12 VDC 21 mA

Current output
0-20 mADC

Load 600 

Ω

  max

.

Linear voltage output

0-10 VDC

4-20 mADC

Load: 1 k

Ω

 min.

Control output 1

The function that is set for the PF 
Setting parameter will operate when 
the 

M

 Key and 

U

 Key are pressed 

at the same time for at least one 
second.

• SUB1: Auxiliary output 1 indicator
   Lit when the function assigned to 

auxiliary output 1 is ON. 

• SUB2: Auxiliary output 2 indicator
   Lit when the function assigned to 

auxiliary output 2 is ON.

• SUB3: Auxiliary output 3 indicator
   Lit when the function assigned to 

auxiliary output 3 is ON.

• HA: Heater burnout alarm/Heater short 

alarm/Heater overcurrent alarm indicator

   Lit when a heater burnout alarm, heater 

short alarm, or heater overcurrent alarm  
has occurred.

• WAIT: Lit while the program is in wait 

status.

• OUT1: Control output 1 indicator

Lit when control output 1 is ON and not lit 
when it's OFF.
For a current output, lit except for a 0% output. 

• OUT2: Control output 2 indicator

Lit when control output 2 is ON and not lit 
when it's OFF. 

• CMW: communications writing enable/ disable 

indicator
Lit when communications writing is 
“enabled” and is out when it is “disabled”.

• FSP: Lit during Constant-value SP Mode. 

RST: Lit while the program is being reset. 

Auxiliary output 

1

Input power supply

*1: Upper and lower limits can be set for parameters 1, 4 and 5 to provide for 

different types of alarm. These are indicated by the letter "L" and "H". 

  • The default alarm type is "2"

*2: Error shown only for "Process value / Set point". Not shown for other status. 

When an error has occurred, the No.1 display shows the error code. Take 
necessary measure according to the error code, referring the table bellow.

If the input value exceeds the display limit ( -19999 to 32400), though it is within the control 
range, 

[[[[

will be displayed under  -19999 and        

]]]]

 above 32400. Under these conditions, 

control output and alarm output will operate normally.
For information on the controllable range, refer to the 

E5CN-HT/E5AN-HT/E5EN-HT Digital Controllers 

User's Manual 

(Cat. No. H169).

Turn the power OFF then back ON again. If the 
display remains the same, the controller must be 
repaired. If the display is restored to normal, then 
a probable cause can be external noise affecting 
the control system. Check for external noise.

After the correction of A/D converter error, turn the 
power OFF then back ON again. If the display 
remains the same, the controller must be repaired. 
If the display is restored to normal, then a 
probable cause can be external noise affecting the 
control system. Check for external noise.

No.1 display

Meaning

A/D converter error 

*2

Memory error

Input error

*2

s.err

(S. Err)

e111

(E111)

Action

OFF

Alarm

Control

output

Status at error

OFF

OFF

Operates 

as above the 

upper limit.

OFF

OFF

e333

 (E333)

Input type

Error display (trouble shooting)

Operation menu

*1

*1

*1

 *The default is“5”.

  *

s.err

 will be displayed when a platinum resistance thermometer is mistakenly connected while 

input type is not set for it. To clear the 

s.err

 display, correct the wiring and cycle the power supply.

Alarms

200.0 to  850.0 (

°C)

199.9 to  500.0 (

°C)

      0.0 to  100.0 (

°C)

199.9 to  500.0 (

°C)

      0.0 to  100.0 (

°C)

200.0 to 1300.0 (

°C)

  

20.0 to  500.0 (

°C)

100.0 to  850.0 (

°C)

  

20.0 to  400.0 (

°C)

200.0 to  400.0 (

°C)

199.9 to  400.0 (

°C)

200.0 to  600.0 (

°C)

100.0 to  850.0 (

°C)

200.0 to  400.0 (

°C)

199.9 to  400.0 (

°C)

200.0 to 1300.0 (

°C)

      0.0 to 1700.0 (

°C)

      0.0 to 1700.0 (

°C)

  100.0 to 1800.0 (

°C)

      0.0 to 2300.0 (

°C)

      0.0 to 1300.0 (

°C)

  

50.00 to 200.00 (

°C)

  

50.00 to 200.00 (

°C)

  

50.00 to 200.00 (

°C)

  

50.00 to 200.00 (

°C)

300.0 to 1500.0 (

°F)

199.9 to  900.0 (

°F)

/      0.0 to  210.0 (

°F)

199.9 to  900.0 (

°F)

/      0.0 to  210.0 (

°F)

300.0 to 2300.0 (

°F)

/      0.0 to  900.0 (

°F)

100.0 to 1500.0 (

°F)

/      0.0 to  750.0 (

°F)

300.0 to  700.0 (

°F)

199.9 to  700.0 (

°F)

300.0 to 1100.0 (

°F)

100.0 to 1500.0 (

°F)

300.0 to  700.0 (

°F)

199.9 to  700.0 (

°F)

300.0 to 2300.0 (

°F)

/      0.0 to 3000.0 (

°F)

/      0.0 to 3000.0 (

°F)

/   300.0 to 3200.0 (

°F)

/      0.0 to 3200.0 (

°F)

/      0.0 to 2300.0 (

°F)

50.00 to 200.00 (

°F)

50.00 to 200.00 (

°F)

50.00 to 200.00 (

°F)

50.00 to 200.00 (

°F)

K

J

T

E

L

U

N

R

S

B

W

PLII

K

J

T

Pt100

4 to 20mA
0 to 20mA

1 to 5V
0 to 5V

0 to 10V

0
1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23

24

25
26
27
28

29

One of the following ranges is used depending on scaling.

  :

 

19999 to 32400

 

1999.9 to 3240.0

 

199.99 to 324.00

   

19.999 to 32.400

Input type

Platinum
resistance
thermometer

Input

Pt100

JPt100

Thermocouple

Platinum

resistance

thermometer

Current input

Voltage input

Setting

Input setting range

Vary with "L", "H" values

Vary with "L", "H" values

Vary with "L", "H" values

X

ON
OFF

SP

X

ON
OFF

SP

ON
OFF

SP

X

X

ON
OFF

SP

L H

ON
OFF

SP

X

ON
OFF

SP

X

ON
OFF

SP

X

ON
OFF

0

ON
OFF

X

0

X

ON
OFF

0

X

ON
OFF

0

ON
OFF

X

0

X

ON
OFF

0

L H

ON
OFF

SP

L

H

ON
OFF

SP

SP

X

ON
OFF

SP

ON
OFF

X

ON
OFF

X

0

ON
OFF

X

0

1

0

2

3

4

5

6

7

8

9

10

11

12

13

Alarm output function

Positive alarm value (X) Negative alarm value (X)

Alarm type

Setting

No alarm function

Deviation upper/lower limit
standby sequence ON

Absolute value upper limit

Absolute value lower limit

Absolute value upper limit
standby sequence ON

Absolute value lower limit
standby sequence ON

LBA (only for alarm 1)

Deviation lower limit 
standby sequence ON

Deviation upper limit
standby sequence ON

Deviation upper/lower range

Deviation upper limit

Deviation upper/lower limit

Deviation lower limit

Output off

PV change rate alarm

Check the setting of the Input Type parameter, 
check the input wiring, and check for broken or 
shorts in the temperature sensor.  

    : Can be displayed 
      and changed
    : Can be displayed
×  : Display or shifting to 
     another level is not 
     possible. 

Default setting : 0

× : Change to other levels not possible 

Protection function

Operation/Adjustment protection

Setting change protection

Setting changes by key operation are restricted. 

OFF

off

: Setting can be changed by key operation 

ON

on

    : Setting cannot be changed by key operation (“       ” will light.) 

(Protect level settings can all be changed.)

Other functions

    : Change to other levels possible  

*

AT in Adjustment level

Designate "

at-2

: 100% AT execute" or

"

at-1

: 40%  AT execute" to execute AT and

"

off

: AT cancel" to cancel AT.

at

” flashes

“AT cancel”

Also when AT execution ends, the 
display automatically returns to “

off

”.           

at

off

at

at-2

AT (auto-tuning)

“100%AT Execute”

Hold 

O

 down for at least 1 second

Adjustment Level

Moving to the next level is 
possible when the password 
(-169) is input. 

Set value

0

1
2

×

×

×

×

Initial setting

level

Communications 

setting level

Advanced function 

setting level

Initial setting/Communications protection

This protect level restricts movement to the initial setting level, 
communications setting level and advanced function setting level.

PID Setting Level

Operation Level

Hold 

O

 

and 

M

keys down for 
at least 1 second

oapt

0

icpt

0

wtpt

off

prlp

0

Protect Level

Operation / Adjustment
Protect

Initial Setting / 

Communication Protect

Setting Change Protect

Password to Move 
to Protect Level

Restricts which settings can be displayed 
or changed, and restricts change by key 
operation.

Advanced Function 
Setting Level

Hold 

O

 

down

for at least

1 second

Hold 

O

 

down for at 

least 3 seconds

Only the value set to the 

ins

: temperature input shift parameter is applied  to 

the entire temperature input range. When the process value is 200°C, the 
process value is treated as 201.2°C after input shift if the input shift value is 
set to 1.2°C. The process value is treated as 198.8°C after input shift if the 
input shift value is set to -1.2°C.   

OMRON EUROPE B.V.

Wegalaan 67-69, NL-2132 JD Hoofddorp The Netherlands
 Phone 31-2356-81-300
 FAX 31-2356-81-388

OMRON ELECTRONICS LLC

One Commerce Drive Schaumburg, IL 60173-5302 U.S.A   
   Phone 1-847-843-7900
 FAX 1-847-843-7787

OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark, Singapore 119967
 Phone 65-6835-3011
 FAX 65-6835-2711

OMRON Corporation

Shiokoji Horikawa, Shimogyo-ku, Kyoto 600-8530 JAPAN

Settings shown below are the parameters displayed for the models without options. 
(Options include heater burnout detection, communications, event inputs, and 
control output 2.) 

Check the wiring before turning ON the power supply. 

The following table shows the relationship between settings and 
protect limits related to Operation level and Adjustment level.

Protection function, to prevent unwanted settings, 
restricts the setting items to be used or designates 
if operation of the key is valid or invalid. 

Input Type *3

Scaling Upper Limit 
(only when setting analog input)

Scaling Lower Limit 
(only when setting analog input)

Decimal Point 
(only when setting analog input)

SP Upper Limit

SP Lower Limit

PID/ONOFF
In ON/OFF control = 

onof

 

In 2-PID control = 

pid

 

Standard or Heating/Cooling

Standard control = 

stnd

Heating and cooling control = 

h-c

(Select standard control or heating 
and cooling control as required) 

Control Period 
(Heating)(Unit: Seconds)

Alarm 2 Type:

Control Period (Cooling)(Unit: 
Seconds)

(C stands for Celsius, 
F for Fahrenheit)

Direct/Reverse OperationIn 
Reverse operation (Heating) = 

or-r

In Direct operation (Cooling) =  

or-d

*3: Refer to the adjoining tables for details of input 

types and alarm types. 

*4: Applicable only to models with alarm functions.
*5: Operation is stopped when moved to the initial 

setting level.
(Control/alarm are both stopped.)

*6: The grayed-out setting items may not be 

displayed according to the models and setting.

*6

*6

*6

*6

*6

*6

*6

*6

Transfer Output Type

Transfer Output Upper Limit

Transfer Output Lower Limit

Linear Current Output

Program Time Unit 

Time Setting/Slope Setting 

Slope Time Setting Unit 

Reset Operation 

Operation after Power ON

Operation at End of Operation 

PV Start 

*6

*6

*6

*6

Default setting : 0

     Process value
     PV/SP
     Others

Program Setting Level
Adjustment level
PID Setting Level

Level

Set value

Oper

a

tion

 le
v

e

l

Alarm 1 Hysteresis

*6

Alarm 2 Hysteresis

*6

Extraction of Square Root Enable
(Only when analog input is set)

*6

*6

*6

*6

Initial setting level enables users to specify their 
preferred operating conditions  
(input type, alarm type, control method, etc.)

Move to Advanced Function 
Setting Level

init

off

For parameters in the Advanced Function Setting 
Level, PID Setting Level, Monitor/Setting Item 
Level, and Manual Control Level and for other 
information, refer to the 

E5CN-HT/E5AN-HT/E5EN-HT User's Manual 

(Cat. No. H169).
For information on communications, refer to the 

E5CN-HT/E5AN-HT/E5EN-HT Communications  
Manual

 (Cat. No. H170).

Temperature Input Shift
(Unit: °C or °F) 

Upper Limit Temperature 
Input Shift Value
when 2 point input shift 
is selected
Lower Limit Temperature 
Input Shift Value
when 2 point input shift 
is selected

Adjustment Level

Proportional Band

Integral Time
(Unit: secs)

AT Execute / Cancel

100%AT Execute

 

at-2

40%AT Execute

 

at-1

*6

*6

*6

*6

*6

*6

l.adj

at

off

SP Mode

*6

spmd

psp

Constant SP 

fsp

0.0

ins

0.0

insh

0.0

insl

0.0

p

8.0

i

233.0

Derivative Time
(Unit: secs)

*6

d

40.0

Dead Band

Manual Reset Value
(Unit: %)

Hysteresis
(Cooling)

MV Upper Limit

MV Lower Limit

Hysteresis
(Heating)

*6

*6

*6

*6

*6

*6

hys

1.0

chys

1.0

ol-h

105.0

ol-l

-5.0

c-db

0.0

of-r

50.0

Cooling Coefficient

*6

c-sc

1.00

Wait Band

*6

wt-b

off

MV Change 
Rate Limit

*6

orl

0.0

Standby Time

stb

0.00

Extraction of Square 
Root Low-cut Point

*6

sqrp

0.0

Adjustment level is for 
entering set values and shift 
values for control. 

d.seg

1

d.seg

0

PID Set 
No. 

pid

1

Alarm 
Value 1 

al-1

0.0

Alarm 
Upper 
Limit 1 

al1h

0.0

Alarm 
Lower 
Limit 1 

al1l

0.0

Alarm 
Value 2 

al-2

0.0

Alarm 
Upper 
Limit 2 

al2h

0.0

Alarm 
Lower 
Limit 2 

al2l

0.0

Alarm 
Value 3 

al-3

0.0

Alarm 
Upper 
Limit 3 

al3h

0.0

Alarm 
Lower
Limit 3 

al3l

0

Program 
Repetitions

rpt

0

Program Link 
Destination

link

end

Time Signal 1 
Set Segment

ts1s

0

Time Signal 1 
ON Time 

on1

0.00

Time Signal 1 
OFF Time

of1

0.00

Segment 
n Format

styp

ramp

Segment 
n SP

sp

0.0

Segment 
n Slope

pr

0.0

Segment 
n Time

time

0.00

Time Signal 2 
Set Segment 

t525

0

Time Signal 2 
ON Time

on2

0.00

Time Signal 2 
OFF Time

of2

0.00

Number of Segments 
Used, 1 to 32 

s-no

8

Display Segment Selection, 

END or 0 to Number of 

Segments − 1

d.seg

end

d.seg

7

d.prg

2

d.prg

1

Display Program Selection

d.prg

0

d.prg

7

In this level, the SPs and times 
are input for the programs. 

t-u

h-m

pru

m

rtsm

stop

p-on

cont

eset

rst

t-pr

time

pvst

sp

amov

0

in-t

5

in-h

100

in-l

0

dp

0

d-u

c

sl-h

1300.0

sl-l

-200.0

cntl

pid

s-hc

stnd

cp

20

c-cp

20

orev

or-r

alt1

2

alt2

2

tr-t

off

tr-h

100.0

tr-l

0.0

o1-t

4-20

alh1

0.2

alh2

0.2

sqr

off

Operation level should normally be 
used during operations. 

PV/SP

s.err

 is displayed when 

connected sensor is 
different from input type.

Segment No. Monitor

Hold

Advance

Run/Reset 
At start of program operation:

 

run

At end of program operation: 

 

rst

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

*6

Program Number 

Auto/Manual Switch 

Elapsed Program 
Time Monitor

Program Execution 
Repetition Monitor

Remaining Standby 
Time Monitor

seg

0

hold

off

adv

off

r-r

rst

prg

0

25.0

0.0

a-m

 

prgt

0.00

rptm

0

stbm

0.00

d.pid

1

Operation stopped.

(Control/alarm are both stopped.)

*5

Initial Setting Level

Temperature Unit °

C = 

c

°

F = 

f

Alarm 1 Type: 

*3
*4

*3
*4

POWER  ON

Press 

O

     

Key for 
less than 
1 s.

Hold 

O

 

and 

M

keys down for 
at least 3 seconds

Program Setting Level

Parameter
Initialization

Press 

O

 Key for 

less than 1 s.

Display PID 
Selection

Press 

O

 Key for 

less than 1 s. 

Press 

O

     

Key for less 
than 1 s.

Protection can be set for the PF Key operation. The PF Key operation is 
executed by pressing the 

M

 and 

U

 Keys at the same time.   

PF key protection

OFF “

off

”: PF Key enabled.

ON   ”

on

”  : PF Key disabled.

For other information, refer to the 

User's Manual

 (Cat. No. H169).

For other information, refer to the 

User's Manual

 (Cat. No. H169).

U

D

48 

×

 48

Summary of Contents for E5CN-HT

Page 1: ... RS 232C and CT transfer output Transfer output Control output 2 rol output 12VDC 21 mA A DC 21 m p p p Control output 2 rol output 12VDC 21 mA A DC 21 m p p p Control output 2 ol output 2 12VDC 21 mA DC 21 mA p p p Load 600 Ω max 4 20 mADC Control output 2 ol output 2 12VDC 21 mA DC 21 m p p p Load 600 Ω max 4 20 mADC Transfer output Relay output 250VAC 3A resistive load Voltage output for drivin...

Page 2: ... ౝኈ䈏ᄌ䉒䉌䈭䈇႐ว䈲ୃℂ䈏ᔅⷐ䈪䈜䇯 ᱜᏱ䈮䈭䈦䈢႐ว䈲䊉䉟䉵䈱ᓇ㗀䈏 䈋䉌䉏䉎䈱䈪䇮 䊉䉟䉵䈏 䈚䈩䈇䈭䈇䈎 䈚䈩䈒䈣䈘䈇䇯 䃂 Ᏹᤨ䈱 䈮䈧䈇䈩䋨䊃䊤䊑䊦䉲䊠䊷䊁䉞䊮䉫䋩 Ᏹ䈏 䈜䉎䈫䇮 䋱 䈮䉣䊤䊷ౝኈ䉕 䈚䉁䈜䇯䉣䊤䊷 䈮䉋䈦䈩䉣䊤䊷 䈱ౝኈ䉕 䈚䇮䈠䈱ౝኈ䈮䈧䈇䈩䈱ಣ 䉕䈚䈩䈒䈣䈘䈇䇯 䃂 ജ 䊶ೋᦼ୯䈲䇸䋵䇹䈪䈜䇯 䊶 ᛶ એᄖ䈱 ቯ୯䈪䇮 䈦䈩 ᛶ 䉕ធ 䈚䈢䈫䈐䈲䇮s err䉕 䈚䉁䈜 䇯 㩷 s err䉕 㒰䈜䉎䈮䈲䇮 䉕 䈚䇮㔚Ḯ䉕 䉏 䈚䈩䈒䈣䈘䈇䇯 䋪㪈䋺 ቯ୯㪈䇮㪋䇮㪌䈲 ႎ 䈱 䊶ਅ㒢୯䈏 䈮 ቯ䈪䈐䇮㪣㪃㪟䈪 䈚䈩䈇䉁䈜䇯 䊶ೋᦼ୯䈲䇸䋲䇹䈪䈜䇯 䃂 ႎ 䋪㪈 䋪㪈 䋪㪈 ႎ 㪣㪃㪟䈱୯䈮䉋䉎 㪣㪃㪟䈱୯䈮䉋䉎 㪣㪃㪟䈱୯䈮䉋䉎 ႎᯏ 䈭䈚 ജ㪦㪝㪝 ਅ㒢ᓙᯏ䉲䊷䉬䊮䉴ઃ ኻ୯ 㒢 ኻ୯ਅ㒢 ኻ୯ 㒢ᓙᯏ䉲䊷䉬䊮䉴ઃ ኻ୯ਅ㒢ᓙᯏ䉲䊷䉬䊮䉴ઃ 㪣㪙㪘䋨 ႎ...

Reviews: