Advanced Digital Temperature Controller

 E5AN-H/E5EN-H

1

Advanced Digital Temperature Controller

E5AN-H/E5EN-H

(96 x 96 mm and 48 x 96 mm)

A New High-performance Controller: 
High Resolution, High Speed, and High Input Accuracy.
With Logic Operations and preventive maintenance functions. 

Plus Infrared Port on Front Panel.

High-resolution display with 5 digits/0.01°C display. 

High-speed sampling cycle of 60 ms.

High Accuracy
Thermocouple/Pt input: ±0.1% of PV
Analog input: ±0.1% FS

Universal inputs on all models (thermocouple, PT, analog) to 
handle various sensors with one Controller. Models also available 
with Remote SP.

A PV/SV-status display function can be set to displaying 
the PV or SV and the status of the Temperature Controller 
(auto/manual, RUN/STOP and alarms).

Flexible contact outputs with logic operations (AND, OR, and 
delays) set from the Support Software (CX-Thermo Ver. 4.0)

Preventive maintenance for relays using a Control Output ON/OFF 
Counter.

Model available with position-proportional control 

Main I/O Functions

96 

×

 96 mm

E5AN-H

48 

×

 96 mm

E5EN-H

Refer to 

Safety Precautions on page 22.

• Auto/manual switching
•  Temperature Controller 
 status 

display

• Simple program 
 function
• Logic operations
•  Control output ON/OFF
 count 

alarm 

•  PV change rate alarm     
•  Models optional with 
  RS-485 or RS-232C 
 communications

Event Inputs 
• None
• Two
• Four

Universal Sensor Inputs 
• Universal thermocouple/
 Pt/analog
 (current/voltage) 

inputs.

Indication Accuracy 

• Thermocouple/Pt input:

  ±0.1% of PV

• Analog input:

 ±0.1% 

FS

Sampling Period and control 
update
• 60 ms

PF Key
(Programmable 
key function)

Auxiliary Outputs 
• Two 
• Three 

Remote SP Input

3-line Display 
Simultaneously displays set items, such as the 
PV, SV, and MV.

5-digit, 11 segment display with high resolution of 0.01°C

Infrared port 

E5AN-H E5EN-H

Computer Support Software  

CX-Thermo 

USB 

Control Output 1
(built-in)
• SSR outputs

Output Unit
• Relay output
• Voltage output (for driving SSR)
• Current output
• Linear voltage output

Control Output 2
(built-in)
• SSR outputs

Output Unit
• Relay output
• Voltage output (for driving SSR)
• Current output
• Linear voltage output

Summary of Contents for E5AN-H

Page 1: ...ON OFF Counter Model available with position proportional control Main I O Functions 96 96 mm E5AN H 48 96 mm E5EN H Refer to Safety Precautions on page 22 Auto manual switching Temperature Controller status display Simple program function Logic operations Control output ON OFF count alarm PV change rate alarm Models optional with RS 485 or RS 232C communications Event Inputs None Two Four Univers...

Page 2: ...C 10 Terminal Cover 500 With Terminal Cover Note Casing color is black White Silver available on request Option Units 1 Function EN01 RS 232C communications EN02 RS 422 communications EN03 RS 485 communications AKB Event input Output Units 1 Function RN relay QN pulse PNP 12 VDC Q3 pulse NPN 12 VDC Q4 pulse PNP 24 VDC C3N linear 4 to 20 mA C3DN linear 0 to 20 mA V34N linear 0 to 10 V V35N linear 0...

Page 3: ...SR output fitted 3 phase 2 4 to 20 mA output 4 to 20 mA input E5AN HSS2HHBFM 500 3 none fitted 2 slots 2 4 to 20 mA output 4 to 20 mA input E5AN HAA3BFM 500 2 SSR output fitted 2 4 to 20 mA output 4 to 20 mA input E5AN HSS3BFM 500 Valve 2 2 relay output fitted 2 4 to 20 mA input E5AN HPRR2BM 500 2 relay output fitted 2 4 to 20 mA output 4 to 20 mA input E5AN HPRR2BFM 500 24 VAC VDC Basic 2 none fi...

Page 4: ...mA input E5EN HAA2HHBFM 500 2 SSR output fitted 3 phase 2 4 to 20 mA output 4 to 20 mA input E5EN HSS2HHBFM 500 3 none fitted 2 slots 2 4 to 20 mA output 4 to 20 mA input E5EN HAA3BFM 500 2 SSR output fitted 2 4 to 20 mA output 4 to 20 mA input E5EN HSS3BFM 500 Valve 2 2 relay output fitted 2 4 to 20 mA input E5EN HPRR2BM 500 2 relay output fitted 2 4 to 20 mA output 4 to 20 mA input E5EN HPRR2BFM...

Page 5: ...or D A or B or C or D A and B and C and D A B C and D are four inputs Delay ON delay or OFF delay for the results of the logic operation given above Setting time 0 to 9999 s or 0 to 9999 min Output inversion Possible Output One work bit per operation Work bit assignment Any of The following can be assigned to up to eight work bits logic operation results Event input operations auxiliary outputs or...

Page 6: ...00 01700 0 1300 0 1300 0 1300 0 850 0 850 0 850 0 600 0 500 0 500 0 500 0 400 0 400 0 400 0 400 0 400 0 200 00 200 00 200 00 200 00 100 0 100 0 100 0 0 0 0 0 0 0 0 0 0 0 0 0 50 00 20 0 50 00 100 0 20 0 50 00 50 00 100 0 200 0 199 9 199 9 200 0 200 0 199 9 200 0 200 0 199 9 200 0 Setting number 0 1 2 24 3 4 5 6 21 7 8 22 9 10 23 11 12 13 14 15 16 17 18 19 20 25 26 27 28 29 Shaded settings are the d...

Page 7: ...ue 5 Upper and lower limit with standby sequence Always OFF when the upper limit and lower limit hysteresis overlaps 6 Displayed when there is a remote SP input Set val ue Alarm type Alarm output operation When X is positive When X is negative 0 Alarm function OFF Output OFF 1 1 Upper and lower limit 2 2 Upper limit 3 Lower limit 4 1 Upper and lower limit range 3 5 1 Upper and lower limit with sta...

Page 8: ... 9 FS in units of 0 1 FS Integral time I 0 0 to 3240 0 s in units of 0 1 s Derivative time D 0 0 to 3240 0 s in units of 0 1 s Control period 0 5 1 to 99 s in units of 1 s Manual reset value 0 0 to 100 0 in units of 0 1 Alarm setting range 19999 to 32400 decimal point position depends on input type Affect of signal source resistance Thermocouple 0 1 C Ω max 100 Ω max Platinum resistance thermomete...

Page 9: ...o condensation or icing Storage humidity 10 to 80 Altitude 2 000 m max Weight Approx 100 g Transmission line connection method RS 485 RS 422 Multipoint RS 232C Point to point Communications RS 485 two wire half duplex RS 422 four wire half duplex or RS 232C Synchronization method Start stop synchronization Protocol CompoWay F SYSWAY or Modbus Baud rate 1200 2400 4800 9600 19200 38400 or 57600 bps ...

Page 10: ...within the derating curve 2 There is no zero cross function Derating Curve for SSR Outputs Reference Values Condition A SSR outputs 100 ON Condition B SSR outputs 50 ON with 2 s control cycle 500 300 100 50 30 10 5 3 1 0 1 2 3 4 5 6 E5AN H E5EN H 250 VAC 30 VDC resistive load cosφ 1 Switching current A Life 10 4 operations 1 5 1 25 1 0 75 0 5 0 25 0 10 0 10 20 30 40 50 55 45 60 Ambient temperature...

Page 11: ...3 4 5 6 7 8 9 10 21 22 23 24 25 26 27 28 29 30 21 22 23 24 25 26 27 28 29 30 11 12 13 14 15 16 17 18 19 20 4 to 20 mA DC Load 600 Ω max 4 to 20 mA DC 21 22 23 24 25 26 27 28 29 30 EV4 EV3 Transfer output Remote SP input DON T USE 100 to 240 VAC 24 VAC VDC no polarity Input power supply Auxiliary output 2 Control output 1 Control output 2 CT2 CT1 CT2 DON T USE DON T USE Auxiliary output 1 Control o...

Page 12: ...ry Crimp terminal size M3 5 96 96 112 91 79 2 6 2 92 0 8 0 92 0 8 0 92 0 8 0 96 number of units 3 5 1 0 0 120 min Group mounting does not allow waterproofing Mounted Separately Group Mounted Recommended panel thickness is 1 to 8 mm Group mounting is not possible in the vertical direction Maintain the specified mounting space between Controllers To mount the Controller so that it is waterproof inse...

Page 13: ... panel thickness is 1 to 8 mm Group mounting is not possible in the vertical direction Maintain the specified mounting space between Controllers When two or more Controllers are mounted make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications Group mounting is not possible if an SSR output is used for control output 1 or 2 and t...

Page 14: ... SD USB Infrared Conversion Cable E58 CIFIR USB Infrared Conversion Cable 16 99 2 18 5 23 1 75 21 8 39 Mounting Adapter Accessory With Mounting Adapter Connected Mounting Adapter 2 100 250 1 765 USB connector type A plug Serial connector LED indicator RD LED indicator SD USB Serial Conversion Cable E58 CIFQ1 Terminal Covers E53 COV16 Six Covers provided 10 1 2 3 2 44 8 ...

Page 15: ...of structure is not required Y92S P5 for DIN 48 96 E54 CT3 Accessory Armature 30 21 15 5 8 dia 25 3 40 10 5 2 8 7 5 10 Two 3 5 dia 40 40 30 12 dia 9 2 36 dia 15 30 Two M3 depth 4 Approx 3 dia 18 22 Approx 6 dia Plug Armature Lead E54 CT1 E54 CT3 Connection Example Plug E54 CT1 Thru current Io vs Output Voltage Eo Reference Values Maximum continuous heater current 50 A 50 60 Hz Number of windings 4...

Page 16: ...16 Advanced Digital Temperature Controller E5AN H E5EN H ...

Page 17: ...OFF then back ON again If the display remains the same the controller must be repaired If the display is restored to normal then a probable cause can be external noise affecting the control system Check for external noise OFF OFF e111 E111 Memory error Turn the power OFF then back ON again If the display remains the same the controller must be repaired If the display is restored to normal then a p...

Page 18: ...Setting Level Adjustment Level Protect Level Monitor Setting Item Level PID Setting Level Bank Setting Level Bank Setting Level Press the O Key less than 1 s Press the O Key less than 1 s Press the O Key less than 1 s PID2 PID3 PID8 PID 8 Integral Time PID 8 Derivative Time PID 8 MV Upper Limit PID 8 MV Lower Limit PID 8 Automatic Selection Range Upper Limit PID 8 Cooling Coefficient PID 8 LBA Det...

Page 19: ...n of P or PD control Hysteresis Heating Hysteresis Cooling Hysteresis settings Soak Time Wait Band MV at Stop MV at PV Error SP Ramp Set Value MV Upper Limit MV Lower Limit MV Change Rate Limit Process Value Added when Additional PV display is ON Process Value Set Point Auto Manual Switch PID control only Added when auto manual select addition is ON Set Point During SP Ramp Heater Current 1 Value ...

Page 20: ...Key Protect Restricts PF key operation E5AN H E5EN H only Parameter Mask Enable Displayed only when a parameter mask is set Protocol Setting Switches between CompoWay F SYSWAY and Modbus Communications Unit No Communications Baud Rate CompoWay F SYSWAY only Communications Data Length Communications Stop Bits Communications Parity Send Data Wait Time Press the O Key for at least 1 s Press the O Key...

Page 21: ...n Compensation Method MB Command Logic Switching PV Change Color PV Stable Band Alarm 1 ON Delay Alarm 2 ON Delay Alarm 3 ON Delay Alarm 1 OFF Delay Alarm 2 OFF Delay Alarm 3 OFF Delay Input Shift Type MV at Stop and Error Addition Auto Manual Select Addition HS Alarm Use HS Alarm Latch HS Alarm Hysteresis LBA Detection Time LBA Level LBA Band Control Output 1 Assignment Control Output 2 Assignmen...

Page 22: ...s to ensure the correct temperature display Do not touch the terminals while power is being supplied Doing so may occasionally result in minor injury due to electric shock Do not allow pieces of metal wire clippings or fine metallic shavings or filings from installation to enter the product Doing so may occasionally result in electric shock fire or malfunction Do not use the product where subject ...

Page 23: ...ed inside a control board the ambient temperature must be kept to under 55 C including the temperature around the product 2 The service life of electronic devices like Temperature Controllers is determined not only by the number of times the relay is switched but also by the service life of internal electronic components Component service life is affected by the ambient temperature the higher the ...

Page 24: ... rear case two on the top and two on the bottom and use it to pry and pull out the front panel slightly Then pull out on the front panel gripping both sides Be sure not to impose excessive force on the panel 3 When inserting the body of the Temperature Controller into the case make sure the PCBs are parallel to each other make sure that the sealing rubber is in place and press the E5AN E5EN toward...

Page 25: ...Advanced Digital Temperature Controller E5 N E5 N H 25 ...

Page 26: ...formity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the products Take all necessary steps to determine the suitability of the product for the systems machines and equipment with which it will be used Know and observe all prohibitions of use applicable to this product NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SE...

Reviews: