5
Specifications
Section 1-2
1-2
Specifications
1-2-1
Performance Specifications
Note
1.
Fiber Amplifier Units that are allocated two unit numbers must be counted
as two Units when counting the number of connected Sensors.
2.
Prewired models (E3X-DA11/21/41/51-N, E3X-DAB11-N, etc.) and water-
resistant models cannot be used. Connecting these Units will disable the
power reset switch.
Item
Specification
E3X-DRT21
E3X-SRT21
E3X-CIF11
Communications method
DeviceNet
CompoBus/S
RS-422
Communications Remote I/O
communications
ON/OFF data, status, and monitoring inci-
dent light levels
(Functions as DeviceNet slave.)
ON/OFF data and
status
(Functions as Com-
poBus/S slave.)
No
Messages com-
munications
Explicit messages
No
Functions as
CompoWay/F
slave.
Setting, moni-
toring, and
operating Sen-
sors from Con-
figurator
Supported from DeviceNet Configurator
(depends on the parameter editing and
device monitoring functions of the slave).
No
No
Mobile Console connection
Yes
Cannot be used at the same time as moni-
toring incident light levels from remote I/O
communications, using explicit messages
communications, or setting, monitoring, or
operating Sensors from the Configurator.
---
Cannot be used
at the same time
as CompoWay/F
message com-
munications.
Power supply (Shared by Commu-
nication Unit and all Fiber Amplifier
Units connected to it.)
From DeviceNet communications connec-
tor
From CompoBus/S
communications
connector
From power sup-
ply cable
Maximum number of Sensors that
can be connected per Unit.
(See note 1.)
13 or 16 (depending on the mode used)
6 or 14 (depending
on the setting for
maximum number
of Sensors)
16
Applicable Fiber Amplifier Units
The following Fiber Amplifier Units with Connectors are supported (See note 2.):
E3X-DA6
E3X-DAB6
E3X-DAG6
E3X-DA6TW
E39-TM1
E3X-DA6-P
E3X-DA8
E3X-DAB8
E3X-DAG8
E3X-DA8TW
Applicable Slave Connectors for
Fiber Amplifier Units
E3X-CN02 Cordless Slave Connector only
E3X-CN02 Cord-
less Slave Connec-
tor only
E3X-CN12 Slave
Connector with
Cord or E3X-
CN02 Cordless
Slave Connector
Power supply cable
None
None
Provided.
Summary of Contents for E3X-CIF11
Page 3: ...iv...
Page 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Page 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Page 107: ...96 CompoWay F Message Communications Section 4 5...
Page 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Page 133: ...122 DeviceNet Connection Settings Appendix C...
Page 135: ...124 DeviceNet Device Profile Appendix D...
Page 137: ...126 Revision History...