111
Appendix B
Monitoring Incident Light Levels of
E3X-DA6-P Sensors
When E3X-DA6-P Sensors are used, the incident light levels for Sensor output ON and Sensor output OFF can
be monitored along with standard incident light levels. The following table shows the typical values for ON/OFF
incident light levels.
Details on ON/OFF incident light level monitoring are provided below.
Note When incident light levels are read using standard incident light level monitoring through communica-
tions, the communications can cause a delay. When the Sensors ON/OFF switching interval is short, this
delay can cause only Sensor OFF data to be read, for example, resulting in the inability to read ON data
(in the same way, it is possible that only ON data is read, and OFF data cannot be read). When E3X-
DA6-P Sensors are used, in addition to standard incident light levels, incident light levels for Sensor out-
put ON and Sensor output OFF can also be monitored.
Type
Mode
Typical value
ON incident light level
L.ON
ON interval peak value
D.ON
ON interval bottom value
OFF incident light level
L.ON
OFF interval bottom value
D.ON
OFF interval peak value
ON
OFF
OFF
OFF
OFF
ON
ON
ON
Incident light
level monitoring
Incident light
level monitoring
Incident light
level monitoring
Summary of Contents for E3X-CIF11
Page 3: ...iv...
Page 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Page 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Page 107: ...96 CompoWay F Message Communications Section 4 5...
Page 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Page 133: ...122 DeviceNet Connection Settings Appendix C...
Page 135: ...124 DeviceNet Device Profile Appendix D...
Page 137: ...126 Revision History...