109
Appendix A
Communications Timing
Communications Timing
This appendix describes the internal processing times for the Fiber Amplifier Sensor Communication Unit. For
details on communications timing for DeviceNet and CompoBus/S masters, refer to the relevant operation
manuals.
Maximum ON/OFF Data Input Delay Time
The maximum delay time for the Fiber Amplifier Sensor Communication Unit is as follows:
E3X-SRT21
• With up to 8 Sensors connected:
Maximum ON/OFF data input delay time for Unit n = 0.1
n + 1.5 (ms)
• With 9 or more Sensors connected:
Maximum ON/OFF data input delay time for Unit n = 0.2
n + 1.5 (ms)
E3X-DRT21
• With up to 8 Sensors connected:
Maximum ON/OFF data input delay time for Unit n = 0.1
n + 2.5 (ms)
• With 9 or more Sensors connected:
Maximum ON/OFF data input delay time for Unit n = 0.2
n + 2.5 (ms)
Summary of Contents for E3X-CIF11
Page 3: ...iv...
Page 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Page 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Page 107: ...96 CompoWay F Message Communications Section 4 5...
Page 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Page 133: ...122 DeviceNet Connection Settings Appendix C...
Page 135: ...124 DeviceNet Device Profile Appendix D...
Page 137: ...126 Revision History...