100
Mounting
Section 5-1
3.
Connect the Fiber Amplifier Units to the Communication Unit side by side
by sliding the Fiber Amplifier Units until the clips on the end and the clips
on the Connector are aligned with the Communication Unit and a “click”
sound is heard.
4.
Use PFP-M End Plates (order separately) to secure both ends.
Note Use the correct procedure to mount the Units, performing step 1 before step
2. Reversing these steps may reduce the mounting strength.
5-1-2
Removing the Units
Use the following procedure to remove the Units.
1,2,3...
1.
Slide the Fiber Amplifier Units away from the Communication Unit to dis-
connect them.
Fiber Amplifier Sensor
Communication Unit
Fiber Amplifier Units
End Plate
Mounting point 1 before point 2 is
the correct order.
Do NOT mount point 1 before
point 2.
Correct
Incorrect