E3NC-LA0

Protective Cap

© 

OMRON Corporation  2013  All Rights Reserved.

Smart Laser Amplifier

E3NC-LA0

INSTRUCTION SHEET

Thank you for selecting an OMRON product. This sheet 
primarily describes precautions
required in installing and operating the product.
• A specialist who has the knowledge of electricity must treat 

the product. 

• Please read this manual carefully, and use it correctly after 

thoroughly understanding the product. 

• Please keep this manual properly for future reference 

whenever it is necessary.

Compatible Communication Unit (Sold Separately)

E3NW Series Communication Unit, Distribution unit E3NW-DS

Installation

1

1-1

Dimensions

1-2

Mounting the Amplifier Unit

Unit: mm

Dimensions in parentheses () indicates the ones with related components.

The cover could come off if it is tilted by 152 degrees or more.

2.6

32.1

16

9.4

37

49.5

4.3

33.5

3.4

159.7

(Max. with the protective cover open)

152°

(Max. with the protective cover open)

39.5

102.4

29.9

26

30.2

5.2

4.2

27.8

10

6.9

DIN Track

Tighten the screw while pressing the End Plate.

Fiber Unit Connection Side Hook

1

2

3

4

5

2

1

Up to 30 Amplifier Units can be connected to
E3NW Series Communication Unit.
Under environments such as vibration, use an End Plate 
even with a single amplifier unit.

Mounting on DIN Track

(1) 

Let the hook on the Amplifier Unit's Sensor Head

  

connection side catch the track. 

(2) 

Push the unit until the hook clicks into place.

Removing from DIN Track

(1) Push the unit in the direction 1.
(2) Lift the unit in the direction of arrow 2 while 

   

performing step (1).

1-3

Mounting the sensor head

Settings

2

Smart Tuning [Easy Sensitivity Setting]

2-4

2-1

Setting and Display Overview

[L/D Indicator

Orange] 

Displays Light ON/Dark ON setting.

[OUT Indicator

Orange]

Turns ON when Output is ON.

[DPC Indicator

Green]

[ST Indicator

Blue]

Turns ON when Smart Tuning is in progress.

Turns ON when Dynamic Power Control is

effective.

[OUT Selection Indicators

Orange]

Green Digital Display

Threshold Level

White Digital

Incident Light
Level

(2/3)

PRECAUTIONS ON SAFETY

PRECAUTIONS FOR SAFE USE

PRECAUTIONS FOR CORRECT USE

Checking the Package Content

• Amplifier Unit: 1      • Instruction Sheet (this sheet): 1 (Japanese, English and Chinese)

The following precautions must be observed to ensure safe operation of the product. Doing so may cause 

damage or fire.

· Do not install the product in the following locations.

  (1) Locations subject to direct sunlight

  (2) Locations subject to condensation due to high humidity

  (3) Locations subject to corrosive gas

  (4) Locations subject to vibration or mechanical shocks exceeding the rated values

  (5) Locations subject to exposure to water, oil, chemicals

  (6) Locations subject to steam

  (7) Locations subjected to strong magnetic field or electric field

· Do not use the product in environments subject to flammable or explosive gases.

· Do not use the product in any atmosphere or environment that exceeds the ratings.

· To secure the safety of operation and maintenance, do not install the product close to high-voltage 

devices and power devices.

· Do not use the product if the case is damaged.

· Burn injury may occur. The product surface temperature rises depending on application conditions, such 

as the ambient temperature and the power supply voltage. Use caution when operating or cleaning the 

product.

· When setting the sensor, be sure to check safety such as by stopping the equipment.

· Be sure to turn off the power supply before connecting or disconnecting wires.

· Do not attempt to disassemble, repair, or modify the product in any way.

· When disposing of the product, treat it as industrial waste.

· Do not miswire such as the polarity of the power supply.

· Be sure to mount the unit to the DIN track until it clicks.

· To prevent electric shock or short circuit, put a protection cap on unused connection power supply 

terminals.

· Do not apply excessive force (9.8N max.) such as tension, compression or torsion to the connector of the 

sensor head that is fixed to the amplifier unit.

· Always keep the protective cover in place when using the product. Not doing so may cause malfunction.

· It may take time until the received light intensity and measured value become stable immediately after 

the power is turned on depending on use environment.

· The product is ready to operate 200 ms after the power supply is turned ON.

· The Mobile Console E3X-MC11, E3X-MC11-SV2 and E3X-MC11-S cannot be connected.

· The mutual interference prevention function does not work when in combination with E3C/E2C/E3X.

· If the unit receives excessive sensor light, the mutual interference prevention function may not work 

properly, resulting in malfunction of the unit. In such case, increase the threshold.

· Sensor communication unit E3NW can be used. E3X-DRT21-S and E3X-CRT/ECT cannot be used.

· If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke, 

immediately stop using the product, turn off the power, and consult your dealer.

· Do not use thinner, benzine, acetone, and lamp oil for cleaning.

114

(Max. with the protective cover open)

10

5

19.2

3.9

11.5

13.8

Joining Amplifier Units

(1) 

Mount the Amplifier Units one at a time onto the DIN track.

     Slide the Amplifier Unit until the communication connector is 

closely attached.(Arrow 3)

(2) 

Use End Plates (PFP-M: separately sold) at the both 
ends of the grouped Amplifier Units to prevent them from 
separating due to vibration or other cause.(Arrow 4)

(3) 

Tighten the screw on the End Plates using a driver.(Arrow 5)

Open the protection cover.

Fix the sensor head with M3 screws.
Apply tightening torque of 0.5N・m for fixing.

1.
2.

Lock Lever

Connector cover: Blue

Setting Reset

Key Lock

Zero Reset

Solution Viewer

L/D

L/D

MODE

MODE

UP/DOWN

UP

+:

Press both

 Refer to "     Convenient 
 Setting Features".

Performs tuning and [ST Indicator] 
turns ON.

Sensitivity Setting

【    】

 

Button

S.TUNE

Minute Threshold 

Adjustment

The green digital value 
changes.

[UP/DOWN

Button

Output Switch

[

L/D

Button

A single press switches between 
Light ON/Dark ON. [L/D] Indicator 
changes.

Mode/OUT Switch

[

MODE

]

Button

Switches between SET mode and RUN mode by a 
long press (3 seconds or longer) of the key. If Push 
short, OUT is switched.

For settings with the Communication Unit, 

refer to the User's Manual that comes with the Communication Unit.

2-2

Switching Control Output

2-3

Sensor Head Display

Set to "Dark ON" to turn ON the output without a sensing object.

[L/D Indicator]  turns          ON.

[STABILITY Indicator: Green]
Turns ON when output is stable.

[OUT Indicator

Orange]

Turns ON when Output is ON.

Press     button.

L/D

Set to "Light ON" to turn the output ON with a workpiece in the detection area.

[L/D Indicator]  turns          ON.

Stable indication

(Green)

ON

OFF

ON

ON

OFF

OFF

ON

Operation indication (Orange)

• 

ON

• 

ON

Stable 
operation 
area

Stable 
operation 
area

Unstable 
operation 
area

Operation 
level

Operation 
level x1.1

Operation 
level x0.9

Workpiece

ON

OFF

ON

OFF

Output

 for Light-on

Output

 for Dark-on

Light intensity

level

*

*

*

Setting to the stable area makes the operation more reliable against the 
environmental changes (temperature, voltage, dust, setting deviation) after 
installation. Be careful on environmental changes when using the sensor in an 
application in which stable area cannot be obtained.

*

2-6

Minute Adjustment of Threshold Level

● 

Smart Tuning Error

UP/DOWN

Hold the key for high-speed 
level adjustment.

Press            button to adjust 
the threshold level.

The threshold level 

becomes higher.

The threshold level 

becomes lower.

Error / Display / Cause

Remedy

Error Origin Tuning Type

2-point Tuning
Full Auto Tuning
Positioning Tuning

All

Other than maximum 
sensitivity tuning

The light level difference 

between Points 1 and 2 are 

extremely small.

Incident light level is too 
high.

Incident light level is too low.

Near Error

Over Error

Low Error

・Change the detection function to the mode of slower response time.

・Move the Sensor Head closer to the sensing object.

・Move the Sensor Head away from the sensing object.

・Move the Sensor Head closer to the sensing object. 

err

err

err

● 

2-point Tuning

Basic Setting

Workpiece is present

2-5

Output switching

9999

OUT Selection Indicator switches to switch the settings.

Push short the [MODE] button in [Measurement Mode].
OUT Selection Indicators (Output 1/Output 2) switch.

1.

2.

OUT Selection Indicator (Output 1)

[Output 1]

OUT Selection Indicator (Output 2)

Push short the [MODE] button in [Measurement Mode].

[Output 2]

● 

Maximum Sensitivity Tuning

Enhancing Durability of the Head against Dust and Stain 

Workpiece is absent

Workpiece is absent

● 

Full Auto Tuning

Setting for a Moving Workpiece

● 

Position Tuning

Setting to Detect by Workpiece Position

● 

Percentage Tuning

Detecting a Transparent or Microscopic Object

● 

Power Tuning

Initializing Light Intensity Changed Due to Dust or Dirt

Workpiece 
is absent

Workpiece is absent

Percentage tuning setting

ON

per

Execution can be done even if the order of workpiece 

exists/not exist is reversed.

1pnt

1pnt

   0

   0

9999

9999

1pnt

1500

9999

5000

1500

2500

2pnt

Workpiece

Received light intensity setting: Adjust to the either higher value of Point 1 and Point 2 power tuning levels.

Threshold setting: Set to the middle between Point 1 and Point 2 received light intensity values.

Received light intensity setting: Adjust the received light amount to "0" when the button is pressed.

Threshold setting: Set the light intensity of approximately 7% when the button is pressed.

Received light intensity setting: Adjust the power tuning level to the maximum received light amount when the button is pressed.

Threshold setting: Set to the middle between the maximum and minimum received light amount values when the button is pressed.

Receiving light setting: Adjusts the receiving light amount to a half of that for the power tuning level with Desirable detection position.

Threshold setting: Set to the same value as the received light amount Desirable detection position.

Received light intensity setting: Adjust it to the received light intensity or power tuning level without detection object.

Threshold setting: Light amount without a workpiece x (1 + Percentage tuning level)

Received light intensity setting: Adjust the power tuning level to the received light amount when the button is pressed.

Threshold setting: Not changed.

When percent tuning setting is ON, only power tuning 

can be performed. Other tunings cannot be performed.

L/D switching can be performed on Output 2 as well.(Refer to 2-2)

It will become susceptible to the influence of 

background objects.

Desirable 

detection 

position

Moving the finger off the button displays "2Pnt". 

Moving the finger off the button displays "2Pnt". 

Workpiece

Setting is Completed

Setting is Completed

Setting is Completed

Setting is Completed

Setting is Completed

Setting is Completed

Hold for 3 seconds or longer

Release the button when "FULL" appears.

Hold for 7 seconds or longer

Release the button when the workpiece passed through.

 Refer to "     Detailed Settings".

Hold for 3 seconds or longer

Hold both for 1 sec. or longer

Do not touch the emitter and receiver 

areas of the sensor head.

A fingerprint may prevent proper 

measurement.

If you accidentally touch it, use a soft 

cloth to wipe it out.

Fix the connector area so that it should 

not be affected by oscillation and 
impact.

Hold for 1 seconds or longer

OPTICAL COMMUNICATION 

POSITION

DIN Track

SOLD SEPARATELY

PFP-□-N

Insert the sensor head, with the lock lever on 
its connector area facing upward, all the way 
into the connector port.
The color of the connector cover for E3NC-LH 
is blue.  
Make sure to avoid misconnection by 
confirming the cover color in advance. 
To remove it, press and hold the lock lever 
then pull the sensor head out.

Meanings of Signal Words

Warning Indications

WARNING

Indicates a potentially hazardous situation which, if not avoided, 

may result in minor or moderate injury or in property damage.

Do not use the product with voltage in excess of the rated voltage.

Excess voltage may result in malfunction or fire.

Never use the product with an AC power supply. Otherwise, 

explosion may result.

WARNING

This product is not designed or rated for ensuring safety of persons 

either directly or indirectly. Do not use it for such purpose.

*

4 0 1

3

2 9 8

-

2

C *

Tuning with regressive reflection is not recommended as the variation of the light values may occur, resulting in malfunction of the product.

Diffuse reflection: Perform tuning with the presence of a 

sensing object.

Regressive reflection: Perform tuning without the 

presence of a sensing object.

After positioning tuning performed, a sensing object must 

be present for both diffuse and regressive reflections.