background image

 

 

 

 

 

 

 

 

 

 

 

E  

C  

 

 

 

 

D4SL-N

EC

 

 

    2006/42/EC 

  EMC

    2004/108/EC 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(

)

 
 

 

 

   

   

   

   

   

 

 

 

 

 

IP67

 

 

 

 

 

1.5 2

 

EN

IEC60127

4A

 

 

(AC125V,1A)

3

 

 

 

 

9mm

 

 

 

 

1/2-14NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

   

   

   

   

 

 

 

(

 

 

 

 

 

 

 

 

(H

2

S SO

2

NH

3

HNO

3

Cl

2

)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

2

S SO

2

NH

3

HNO

3

Cl

2

 

 

 

6

 

1

 

 

LOCK

UNLOCK

   

UNLOCK

LOCK

 

D4SL-N

A

UNLOCK

 

D4SL-N

G

LOCK

 

UNLOCK

 

 

 

0.2N m

 

 

LOCK

 

 

 

 

 

 

 

 

 

 

 

 

0.4

0.5 N m 

 

D4SL-NK

G  

0.75

1.15 N m 

 

D4SL-NK

NK

S   2.4

2.8 N m 

 

0.75

1.15 N m 

 

1.8

2.2 N m G1/2 M20  

1.4

1.8 N m  1/2-14NPT  

 

2

 

M4

 

4±0.1

1.5

 

(D4SL-NK

)

 

 

 

 

0.8mm

 

 

 

 

3

 

 

D4SL-K

 

 

3

 

 

 

 

   

4

 

 

 

 

5

 

 

   

 

 

NC

 

DC24V

E1

E2

 

 

DC24V

 

 

 

6

 

 

 

AWG24

22 0.2

0.3mm

2

AWG24 

2A

 

 

 

 

D4SL-N

 

D4SL-N

 

 

 

 

 

 

 

 

 

XHP-10 

 

AWG24

22  

SXH-001T-P0.6 

 

 

 

1/2-14NPT

IP67

 

 

 

 

 

9mm

 

9mm

 

IP67

 

 

 

 

 

G1/2 

LAPP 

ST-PF1/2    5380-1002 

6.0

12.0mm 

 

 

LS-2G 

 

6.0

11.0mm 

M20 

LAPP 

ST-M20×1.5  5311-1020 

7.0

13.0mm 

1/2-14NPT  LAPP 

ST-NPT1/2    5301-6030 

6.0

12.0mm 

JPK-16

GPM20

 

LAPP

             

  TEL 043 423 8741 

   

    http://www.ace-service.co.jp 

1/2-14NPT

 

 

 

 

 

 

 

 

 

EMC

EN1088 EN50047 GS-ET-19 

EN60947-5-1 IEC60947-5-1, UL508 CSA  C22.2 No.14 

EN

 

AC-15          DC-13 

      AC120V          DC125V 
      1.5A                  0.22A 

UL CSA

 

C150            R150 

        AC120V        DC125V 

1800VA       

28VA 

180VA         

28VA 

 

(

) 15mm 

(

) 60N 

1300N  GS-ET-19  

0.05

1m/s 

5

/  

100A   

  4A

 

  (IEC60127)

 

67(EN60947-5-1)  (

IP00) 

TYPE 4X INDOOR USE ONLY (UL, CSA) 

DC5V 1mA

(

10

55

  (

95 RH

 

100

   

15

  (AC125V   1A

 

    DC24V+10 /-15      

-

 

 

D4SL-N |N/P/Q/R| 

-

6.4 -0.27A 

                                      D4SL-N |

-

4.8 -0.2A 

   

2.6W

0.15A

 

(LED)  

DC24V     

10mA 

B10d 2,000,000 

ON/OFF

 

 

 

 

 

 

 

a)

 

b)

 

c)

 

d)

24

 

e)

 

 

*

 

 

 

 

 

 

 

0120-919-066

 

 

PHS

 

 

 

055-982-5015

 

 

 

8 00

21 00       

365

 

FA

 

055-977-6389

 

 

 

9 00

12 00/13 00 17 30 

 

 

 

FAX

 

 

  FAX 055-982-5051 

 

 

 

 

Original instruction 

EC Declaration of Conformity 

OMRON declares that D4SL-N is in conformity with the requirements of the 

following EC Directives: 

  Machinery Directive 2006/42/EC 

  EMC Directive 2004/108/EC 

Safety Precaution 

Definition of Precautionary Information 

 

Indicates  an  imminently  hazardous  situation 
which, if not avoided, is likely to result in serious 
injury or may result in death. Additionally there 
may be severe property damage. 

 

 

Indicates  a  potentially  hazardous  situation 
which,  if  not  avoided,  may  result  in  minor  or 
moderate injury or in property damage. 

Precautionary Information 

DANGER 

Always  verify  the  operation  of  the  safety  functions 
before starting the system.Not do so may result that 
the safety functions may not be performed as expected 
if  wiring  or  settings  are  incorrect  or  the switch  have 
failed.The controlled system may continue to operate 
and possibly resulting in injury or death. 

 

 

CAUTION

 

Do  not  dismount  the  operation  key  from  the 

door  intentionally  and  insert  it  to  the  switch 

with  the  door  open.  Machine  may  start 

operating and injury or death may be caused. 

Do  not  apply  force  exceeding  the  specified  maximum 

holding  force.  Doing  so  may  damage  the  switch  lock 

mechanism and the system may continue to operate, 

possibly resulting in injury or death. Either install another 

locking  component  (e.g.,  a  hook)  in  addition  to  the 

Switch,  or  use  a  warning  measures  or  an  indicator 

showing  the  controlled  system  is  locked  to  avoid 

overloading the holding force in lock mode. 

 

Precautions for Safe Use

 

1. Environment 

1-1. Do not use the switch where explosive gas, ignitable gas, or any other harmful  

gasses may be present. 

1-2. Do not use the switch in the oil and in the water. IP67(EN60947-5-1) 

1-3. Though the switch body is protected from the ingress of dust or water, avoid 

the ingress of foreign substance through the key hole on the head. 

Otherwise, wear in short time or break may be caused 

2. Wiring 

2-1. Connect the fuse to the switch in series to prevent it from short circuit damage.  

The value of the breaking current of the fuse must be increased to cover the 

rated current by 150 to 200%. When using the switch with EN rating, use 4 A 

fast acting fuse that complies with IEC 60127. 

2-2. On the switching of general loads (125VAC/1A), do not operate three circuits or 

more at the same time. Otherwise, insulation performance may be degraded. 

2-3. Keep the electrical load below the rated value. 

2-4.Use a metallic connector which has a threaded portion of 9 mm length or less.  

2-5. Do not use metal conduit with this switch. The broken conduit hole may cause 

electrical shock hazard. 

2-6.Use of a 1/2-14NPT connector may result in damage to a conversion adapter, 

causing defective sealing or a risk of electric shock. Do not use metallic 

connectors. 

2-7. Be sure to install a cover after the wiring. 

Do not put the electric power when opening a cover. 

Do not put the electric power when wiring. 

3. Mounting 

3-1. Be careful not to drop your D4SL-N, or the switch     

will not fully exhibit its ability. 

3-2. This may cause a risk of personal injury. 

Extra care must be taken not to drop this Product   

during installation.. 

3-3. Install operation key so that it will not hit the operator 

when the door is open. Injury may be caused. 

3-4.Do not use the switch as a stopper. 

Be sure to install a stopper as shown in the following   

illustration to prevent the edge of the operation key   

from inadvertently hitting the switch directly. 

4. Others 

4-1. Do not disassemble or remodel your D4SL-N in any case, or the D4SL-N will 

not operate normally. 

4-2. Evaluate the switch under actual working conditions before permanent 

installation. 

The durability of the switch is seriously affected by operating conditions. 

4-3. Please mention in machine manufacturer’s Instruction.   

Manual that the user must not repair nor maintain the switch and must 

contact machine manufacturer for them. 

Precautions for Correct Use

 

1. About the solenoid lock type 

 

1-1. Be sure to energize the solenoid with the door closed (with the operation key 

inserted). A malfunction will occur in Solenoid lock when energizing the 

solenoid before closing the door. 

    1-2. In the solenoid lock type, a lock is closed only when the sol enoids are energized. 

A lock may be opened when the passage of an electric current to the solenoid is 

stopped due to sudden power failure. Do not use the solenoid lock type for the 

machine in which the inside of the door remains dangerous even after 

shutdown of the machine. 

2. Environment 

    2-1. The switch is intended for indoor use only. 

 

2-2. Do not use your D4SL-N outdoor, or the switch will malfunction. 

    2-3. Do not use your D4SL-N in the atmosphere of hazardous gases (H

2

S, SO

2

, NH

3

HNO

3

, CI

2

, etc.) or high temperature and humidity, or it will cause the 

imperfect closing of the contacts or the breakage thereof stemming from 

corrosion. 

    2-4. Do not use the switch under any of the conditions mentioned below. 

  Frequent temperature range. 

  High humidity or dew condensation may be generated. 

  Where the switch is subject to severe vibration. 

  Where the metal dust, oil, or chemical is sprayed inside the door. 

  Where thinner is applied. 

3. Storage 

3-1. Do not keep the switch in dusty, humid place and any place where gas may be 

present for example H

2

S, SO

2

, NH

3

, HNO

3

, Cl

2

    3-2. A switch that has been stored for more than six months must be checked again 

before use. 

4. Using the release key    (See Figure 1) 

    4-1. The release key is used to open a lock in the case of power failure or 

emergency. 

    4-2. Turn the release key from the LOCK position to the UNLOCK position to 

release the lock. This can open the safety door. (For the mechanical lock type  

only.) 

    4-3.When the release key is turned to the UNLOCK position for maintenance or 

other purposes, make sure to turn it back to the LOCK position before using it. 

    4-4. The set position of the release key at the shipping of the switch is as noted 

below;   

D4SL-N

A : UNLOCK position    D4SL-N

G : LOCK position 

    4-5. While the release key is in the UNLOCK position, a lock is not closed and a 

machine is not activated even when the door is closed in the course of 

preliminary adjustment work performed inside a large machine or a 

depressing type machine. 

    4-6. Do not use the release key when starting or stopping the machine. 

    4-7. The releasing of the auxiliary lock must be handled by an authorized person. 

    4-8. Do not apply an excessive force (of 0.2N m or more) to the threaded portion of 

the release key. The release key may be damaged to the extent that it no 

longer becomes operational. 

    4-9. To avoid an unauthorized person's access to the release mechanism, set the 

release key to the LOCK position, and then seal the release key with a seal 

wax (or wax coatings). 

5. Installing the cover 

    5-1. Confirm that the seal rubber has no abnormality and then use it.   

If the seal rubber is displaced or floated, or if foreign matters adhere to the seal 

rubber, the seal rubber will lose its sealing capability. 

    5-2. Do not use any screw other than correct one, or the sealing capability of the 

seal rubber will deteriorate. 

6. About the hinge type door 

    6-1. A door is mounted near a hinge, excessive load may be imposed beyond a force  

acting on the lock portion of this Equipment. This may result in damage to the  

lock mechanism. Mount it to a position near a handle.  

7. Mounting method 

    7-1. Mounting screw tightening torque loose mounting may result in malfunction.   

Fasten the screws to the specified torque. 

Cover clamping screw 

0.4 to 0.5 N m 

Operation key clamping screw  D4SL-NK G                              

0.75 to 1.15 N m 

Operation key clamping screw   

D4SL-NK ,NK S

       

   

2.4 to 2.8 N m 

Body clamping screw

       

     

0.75 to 1.15N m 

Conduit mounting connection   

1.8 to 2.2 N m (G1/2,M20) 

1.4 to 1.8 N m (1/2-14NPT) 

7-2. Switch, operation key    (See Figure 2) 

1) The switch and operation key will be fastened to specified torque in clause 7-1 

with M4 screws and washers. 

2) The switch can be fastened more firmly by a stud(4mm dia., 1.5mm max height) 

inserted from back side at the hole of the switch. 

3)  Do  not  use  the  operation  key  other  than  dedicated  OMRON’s  (D4SL-NK ). 

Otherwise switch may be damaged. 

4)  Be  sure  that  the  operation  key  can  be  inserted  properly  to  key  hole  with  a 

tolerance of 

±

  0.8mm. 

5) Insert the operation key into the key hole according to the specified  “operation 

key insertion radius in horizontal direction”. 

6) Do not impose excessive force on the key top while the operation key is inserted 

into the switch body or drop the switch with the operation key inserted to avoid 

the deformation of the key or the breakage of the switch body. 

7)  When  mounting  at  the  side  of  switch  body,  mount  the  switch  with  3  points 

including the head.     

8) Attach cap heads to any operation key holes that are not being used. 

9) Do not use the operation key D4SL-K . A lock will not be closed and a machine 

will not be activated. 

7-3. Securing of the door    (See Figure 3) 

1) If the operation key is pulled in the opening direction due to a force caused by  

vibration, by the door weight, or by a cushion attached to the door.  The closed 

door must be secured with a hook or by similar means. 

  7-4. Spacer (See Figure 4) 

      1) Do not remove the spacer. Use the switch with the spacer rotated appropriate 

for the mounting direction. Lock strength will decrease when using the switch 

without spacer. 

8. Wiring 

8-1. Example of circuit connections (See Figure 5) 

1).

 

Internal  circuit  of  the  switch  inside  is  different  according  to  the  part 

number. Please confirm the circuit diagram on the product body when 

using. 

2).  The  open  circuit  operating  contacts  are  labeled  with  arrow  marks.  They  are 

able to used as input to the safety circuit.   

3).

  Please  make  the  system  that  can  observe  both  the  door  open/close 

detection  switch  and  the  lock  monitor  switch  NC  contacts  close  when 

the lock is necessary on safety.   

4). The 24VDC solenoid has a polarity. (E1: Positive (+) polarity, E2:  Negative (-) 

polarity) 

5). Current consumption of the solenoid is different in inrush and constant.  

      Apply the rated working voltage to the solenoid. 

8-2. Wiring    (See Figure 6) 

1). Do not put the electric power when wiring. 

2). Do not let particles such as small piece of lead wire in the switch body when 

wiring. 

3). Adequate conductor size is AWG 24 to 22 (0.2 to 0.3mm

2

).   

Do not pass a current of 2 A or more when using AWG24. 

4). Wire leads as shown in the following figure. Otherwise, the switch cover d oes 

not fit. 

5). Do not pull on lead wires with excessive force. The wires may break.  

6). Do not force    the cable-side socket

 

  into the connector and D4SL-N conduit 

opening. Doing so may break the crimped wires . 

Be sure to insert the cable into the connector and D4SL-N conduit opening first 

and then attach the socket to the cable, or to insert the other end of the cable 

into the connector and the conduit opening. 

 

Cable-side socket 

Manufacturer 

Name 

Type 

J.S.T. 

Housing 

XHP-10 

Contact 

(Applicable Electric Wire AWG24~22) 

SXH-001T-P0.6 

9. Conduit opening 

1). Use the connectors recommended in clause 10 and tighten the connector with 

specified torque in clause 7-1. An excessive torque will bring a case breakage. 

2). When using the connector size of 1/2-14NPT, apply the sealing tape between 

connector and conduit opening so that the enclosure will conform to IP67.   

3). Use a cable with a suitable diameter for the connector.   

10. Recommendation of connector 

For easy wiring, use a connector that has the screw part with 9 mm or less in 

length.         

 

Use below listed connector to secure IP67. 

Size 

Manufacturer 

Type 

Adequate cable 

Diameter 

G1/2 

LAPP 

ST-PF1/2        5380-1002 

6.0 to 12.0 mm 

ACE 

SERVICE 

LS-2 

(Short type) 

6.0 to 11.0 mm 

M20 

LAPP 

ST-M20

×

1.5

 

5311-1020 

7.0 to 13.0 mm 

1/2-14NPT  LAPP 

ST-NPT1/2      5301-6030 

6.0 to 12.0 mm 

Use an optional seal packing (Type: JPK-16 or GPM20). 

Tighten the seal packing to a proper tightening torque.  

LAPP is a German manufacturer.   

Ace Service is a Japanese manufacturer. 

Before a connector of 1/2-14NPT size is used, install a supplied conversion 

adapter on the switch and wrap it in seal tape. 

11. Others 

11-1. Please do a regular check in premeditation for this switch  

12. Technical specification 

Conformity: Machine Directive, Low Voltage Directive, EMC Directive, 

EN1088 EN50047,GS-ET-19 

Approval EN60947-5-1 IEC60947-5-1 UL508 CSA

 

C22.2 No.14 

EN electrical rating 

Utilization category AC-15/DC-13 

Rated Voltage

     

120VAC / 125VDC 

Rated Current

     

1.5A / 0.22A 

UL, CSA electrical rating  

C150                    R150 

Voltage       120VAC                125VDC 

Volt Amp.   Make 1800VA      28VA 

Break 180VA        28VA 

Overvoltage Category     

Direct opening travel (min.) 

15 mm 

Direct opening force (min.) 

60 N 

Holding force (min.)    1300N (GS-ET-19) 

Operating speed 0.05 to 1 m/s 

Operating frequency 5 operation / minute max. 

Conditional short-circuit current    100A 

Short circuit protective device Use 4 A fast acting fuse in accordance with 

                                                              IEC 60127 

Enclosure rating IP67 (EN60947-5-1)    (Operation key insertion face : IP00) 

                                  TYPE 4X INDOOR USE ONLY (UL, CSA) 

Minimum permissible load: 5VDC, 1mA resistive load (N level: reference value) 

Ambient temperature range -10 to +55

 

(Protect against Frost) 

Ambient humidity (max.): 95%RH 

Mechanical durability (min.) 1,000,000 operations 

Electrical durability (min.) 150,000 operations

 

(125VAC,1A resistive load) 

Solenoid   Rated working voltage 24VDC+10%/-15% 

Power-Current consumption  

Inrush 

D4SL-N |N/P/Q/R | 

-

N    Approximately 6.4W-0.27A 

D4SL-N |A/B/C/D/E/F/G/H/S/T/U/V | 

-

Approximately 4.8W-0.2A 

Constant Approximately 2.6W-0.15A (max.) 

Indicator lamp(LED)    Rated voltage 24VDC

 

 

Current consumption Approximately 10mA   

B10d : 2,000,000 

There is no equality between the ON/OFF motions of a contact. 

The  switch  contacts  are  common  use  for  general  load  and  micro  load  but,  after 

switching  a  general  load,  it  is  impossible  to  switch  a  micro  load  with  the  same 

contacts.  The  contact  reliability  would  be  decrease  due  to  the  rough  contact 

surface. 

Liability for use in safety systems 

OMRON  shall  not  be  responsible  for  conformity  with  any  standards,  codes,  or 

regulations that apply to the combination of the products in the 

customer's application or use of the product.     

Take all necessary steps to determine the suitability of the product for the systems, 

machines, and equipment with which it will be used.     

Know and observe all prohibitions of use applicable to this product. 

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS 

RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS 

A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE 

OMRON  PRODUCT  IS  PROPERLY  RATED  AND  INSTALLED  FOR  THE 

INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 

See also Product catalog for Warranty and Limitation of Liability.

 

 

OMRON Corporation Industrial Automation Company 

OMRON EUROPE B.V. 

Wegalaan 67-69-2132 JD Hoofddorp The Netherlands 

Tel: (31)2356-81-300 / Fax: (31)2356-81-388 

OMRON ASIA PACIFIC PTE. LTD. 

No. 438A Alexandra Road # 05-05/08 (Lobby 2),Alexandra Technopark, Singapore 

119967 

Tel: (65) 6835-3011 / Fax: (65) 6835-2711 

OMRON SCIENTIFIC TECHNOLOGIES INC. 

6550 Dumbarton Circle, Fremont CA 94555-3605 U.S.A. 

Tel: (1) 510-608-3400 / Fax: (1) 510-744-1442 

OMRON (CHINA) CO., LTD. 

Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road,PuDong New Area, 

Shanghai, 200120, China 

Tel: (86) 21-5037-2222 / Fax: (86) 21-5037-2200

 

 

Traceability Information 

Representative in EU 

  OMRON EUROPE B.V. 

        Wegalann 67-69 2132 JD Hoofddorp The Netherlands 

Manufacturer 

 

 

OMRON CORPORATION, Safety Device Division 

   

 

Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 JAPAN

 

 

 

 

   

Guard Lock Safety-door Switch 

                        

 

 

           Manvel d’Instrvctions 

  Instruction Sheet    manuale d’Instruzioni 
  Bertriebsanleitung   manuale de Instrucciones 

 

 

 

 

 

 

 

DANGER 

CAUTION 

 

 

 

 

 

 

 

 

 

 

 

Thank you for purchasing this D4SL-N. This INSTRUCTION MANUAL described the information such as 

function, performance and how to use the product required for using the D4SL-N. 

For using this product, please follow keep the precautions as shown in the following: 

 

Ensure  that  this  product  is  installed  and  operated  by  qualified  personal  having  sufficient  skills  in 

mechanics and electrotechnic. 

 

Ensure that you understood this manual and that you use the product as described in this manual. 

 

Keep this instruction manual close at hand and use it for reference during operation. 

EU

EU

www.industrial.omron.eu/safety.

 

Instructions in the official EU languages and a signed EC Declaration of Conformity in English are available on our website at www.industrial.omron.eu/safety. 

2219499-7 A 

1 Fig.1  

3 Fig.3  

5 Fig.5  

6 Fig.6  

2 Fig.2  

M4

Front

4±0.1 dia. 1.5mm high max

22±0.1

41.7±0.15

Side

22±0.1

38.7±0.1

10±0.1

41.7±0.15

M4

4±0.1 dia. 1.5mm high max

D4SL-N

-

N

 

D4SL-N

-

4N

 

LOCK

 

UNLOCK

 

LOCK

 

UNLOCK

 

4 Fig.4  

D4SL-NK3

 

D4SL-NK1G/-NK2G

 

D4SL-NK1/-NK1S/-NK2

 

2-M4

 

15

±

0.1

 

2-M4

 

40

±

0.1

 

2-M4

 

12

±

0.1

 

or  20±0.1

 

Head 

E1
( )

21

33

11

22

34

42

52

51

E2
( )

12

41

64

63

7

3

1

10

8

4

2

9

5

6

for D4SL-N

N

-D

LED

Lock M onitor Switch)

To Safety Circuit

To Control Circuit

To Safety Circuit

Door Open/Close

Detection Switch)

To Control Circuit

E1
( )

21

31

22

32

42

E2
( )

41

62

61

7

3

1

10

8

4

2

9

5

6

for D4SL-N

V

Lock M onitor Switch)

To Control Circuit

To Safety Circuit

Door Open/Close

Detection Switch)

To Control Circuit

AND

(for D4SL-N N

-D N) 

(for D4SL-N V

- N) 

 

 

 

 

 

 

 

 

 

 

 

E  

C  

 

 

 

 

D4SL-N

EC

 

 

    2006/42/EC 

  EMC

    2004/108/EC 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(

)

 
 

 

 

   

   

   

   

   

 

 

 

 

 

IP67

 

 

 

 

 

1.5 2

 

EN

IEC60127

4A

 

 

(AC125V,1A)

3

 

 

 

 

9mm

 

 

 

 

1/2-14NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

   

   

   

   

 

 

 

(

 

 

 

 

 

 

 

 

(H

2

S SO

2

NH

3

HNO

3

Cl

2

)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

2

S SO

2

NH

3

HNO

3

Cl

2

 

 

 

6

 

1

 

 

LOCK

UNLOCK

   

UNLOCK

LOCK

 

D4SL-N

A

UNLOCK

 

D4SL-N

G

LOCK

 

UNLOCK

 

 

 

0.2N m

 

 

LOCK

 

 

 

 

 

 

 

 

 

 

 

 

0.4

0.5 N m 

 

D4SL-NK

G  

0.75

1.15 N m 

 

D4SL-NK

NK

S   2.4

2.8 N m 

 

0.75

1.15 N m 

 

1.8

2.2 N m G1/2 M20  

1.4

1.8 N m  1/2-14NPT  

 

2

 

M4

 

4±0.1

1.5

 

(D4SL-NK

)

 

 

 

 

0.8mm

 

 

 

 

3

 

 

D4SL-K

 

 

3

 

 

 

 

   

4

 

 

 

 

5

 

 

   

 

 

NC

 

DC24V

E1

E2

 

 

DC24V

 

 

 

6

 

 

 

AWG24

22 0.2

0.3mm

2

AWG24 

2A

 

 

 

 

D4SL-N

 

D4SL-N

 

 

 

 

 

 

 

 

 

XHP-10 

 

AWG24

22  

SXH-001T-P0.6 

 

 

 

1/2-14NPT

IP67

 

 

 

 

 

9mm

 

9mm

 

IP67

 

 

 

 

 

G1/2 

LAPP 

ST-PF1/2    5380-1002 

6.0

12.0mm 

 

 

LS-2G 

 

6.0

11.0mm 

M20 

LAPP 

ST-M20×1.5  5311-1020 

7.0

13.0mm 

1/2-14NPT  LAPP 

ST-NPT1/2    5301-6030 

6.0

12.0mm 

JPK-16

GPM20

 

LAPP

             

  TEL 043 423 8741 

   

    http://www.ace-service.co.jp 

1/2-14NPT

 

 

 

 

 

 

 

 

 

EMC

EN1088 EN50047 GS-ET-19 

EN60947-5-1 IEC60947-5-1, UL508 CSA  C22.2 No.14 

EN

 

AC-15          DC-13 

      AC120V          DC125V 
      1.5A                  0.22A 

UL CSA

 

C150            R150 

        AC120V        DC125V 

1800VA       

28VA 

180VA         

28VA 

 

(

) 15mm 

(

) 60N 

1300N  GS-ET-19  

0.05

1m/s 

5

/  

100A   

  4A

 

  (IEC60127)

 

67(EN60947-5-1)  (

IP00) 

TYPE 4X INDOOR USE ONLY (UL, CSA) 

DC5V 1mA

(

10

55

  (

95 RH

 

100

   

15

  (AC125V   1A

 

    DC24V+10 /-15      

-

 

 

D4SL-N |N/P/Q/R| 

-

6.4 -0.27A 

                                      D4SL-N |

-

4.8 -0.2A 

   

2.6W

0.15A

 

(LED)  

DC24V     

10mA 

B10d 2,000,000 

ON/OFF

 

 

 

 

 

 

 

a)

 

b)

 

c)

 

d)

24

 

e)

 

 

*

 

 

 

 

 

 

 

0120-919-066

 

 

PHS

 

 

 

055-982-5015

 

 

 

8 00

21 00       

365

 

FA

 

055-977-6389

 

 

 

9 00

12 00/13 00 17 30 

 

 

 

FAX

 

 

  FAX 055-982-5051 

 

 

 

 

Original instruction 

EC Declaration of Conformity 

OMRON declares that D4SL-N is in conformity with the requirements of the 

following EC Directives: 

  Machinery Directive 2006/42/EC 

  EMC Directive 2004/108/EC 

Safety Precaution 

Definition of Precautionary Information 

 

Indicates  an  imminently  hazardous  situation 
which, if not avoided, is likely to result in serious 
injury or may result in death. Additionally there 
may be severe property damage. 

 

 

Indicates  a  potentially  hazardous  situation 
which,  if  not  avoided,  may  result  in  minor  or 
moderate injury or in property damage. 

Precautionary Information 

DANGER 

Always  verify  the  operation  of  the  safety  functions 
before starting the system.Not do so may result that 
the safety functions may not be performed as expected 
if  wiring  or  settings  are  incorrect  or  the switch  have 
failed.The controlled system may continue to operate 
and possibly resulting in injury or death. 

 

 

CAUTION

 

Do  not  dismount  the  operation  key  from  the 

door  intentionally  and  insert  it  to  the  switch 

with  the  door  open.  Machine  may  start 

operating and injury or death may be caused. 

Do  not  apply  force  exceeding  the  specified  maximum 

holding  force.  Doing  so  may  damage  the  switch  lock 

mechanism and the system may continue to operate, 

possibly resulting in injury or death. Either install another 

locking  component  (e.g.,  a  hook)  in  addition  to  the 

Switch,  or  use  a  warning  measures  or  an  indicator 

showing  the  controlled  system  is  locked  to  avoid 

overloading the holding force in lock mode. 

 

Precautions for Safe Use

 

1. Environment 

1-1. Do not use the switch where explosive gas, ignitable gas, or any other harmful  

gasses may be present. 

1-2. Do not use the switch in the oil and in the water. IP67(EN60947-5-1) 

1-3. Though the switch body is protected from the ingress of dust or water, avoid 

the ingress of foreign substance through the key hole on the head. 

Otherwise, wear in short time or break may be caused 

2. Wiring 

2-1. Connect the fuse to the switch in series to prevent it from short circuit damage.  

The value of the breaking current of the fuse must be increased to cover the 

rated current by 150 to 200%. When using the switch with EN rating, use 4 A 

fast acting fuse that complies with IEC 60127. 

2-2. On the switching of general loads (125VAC/1A), do not operate three circuits or 

more at the same time. Otherwise, insulation performance may be degraded. 

2-3. Keep the electrical load below the rated value. 

2-4.Use a metallic connector which has a threaded portion of 9 mm length or less.  

2-5. Do not use metal conduit with this switch. The broken conduit hole may cause 

electrical shock hazard. 

2-6.Use of a 1/2-14NPT connector may result in damage to a conversion adapter, 

causing defective sealing or a risk of electric shock. Do not use metallic 

connectors. 

2-7. Be sure to install a cover after the wiring. 

Do not put the electric power when opening a cover. 

Do not put the electric power when wiring. 

3. Mounting 

3-1. Be careful not to drop your D4SL-N, or the switch     

will not fully exhibit its ability. 

3-2. This may cause a risk of personal injury. 

Extra care must be taken not to drop this Product   

during installation.. 

3-3. Install operation key so that it will not hit the operator 

when the door is open. Injury may be caused. 

3-4.Do not use the switch as a stopper. 

Be sure to install a stopper as shown in the following   

illustration to prevent the edge of the operation key   

from inadvertently hitting the switch directly. 

4. Others 

4-1. Do not disassemble or remodel your D4SL-N in any case, or the D4SL-N will 

not operate normally. 

4-2. Evaluate the switch under actual working conditions before permanent 

installation. 

The durability of the switch is seriously affected by operating conditions. 

4-3. Please mention in machine manufacturer’s Instruction.   

Manual that the user must not repair nor maintain the switch and must 

contact machine manufacturer for them. 

Precautions for Correct Use

 

1. About the solenoid lock type 

 

1-1. Be sure to energize the solenoid with the door closed (with the operation key 

inserted). A malfunction will occur in Solenoid lock when energizing the 

solenoid before closing the door. 

    1-2. In the solenoid lock type, a lock is closed only when the sol enoids are energized. 

A lock may be opened when the passage of an electric current to the solenoid is 

stopped due to sudden power failure. Do not use the solenoid lock type for the 

machine in which the inside of the door remains dangerous even after 

shutdown of the machine. 

2. Environment 

    2-1. The switch is intended for indoor use only. 

 

2-2. Do not use your D4SL-N outdoor, or the switch will malfunction. 

    2-3. Do not use your D4SL-N in the atmosphere of hazardous gases (H

2

S, SO

2

, NH

3

HNO

3

, CI

2

, etc.) or high temperature and humidity, or it will cause the 

imperfect closing of the contacts or the breakage thereof stemming from 

corrosion. 

    2-4. Do not use the switch under any of the conditions mentioned below. 

  Frequent temperature range. 

  High humidity or dew condensation may be generated. 

  Where the switch is subject to severe vibration. 

  Where the metal dust, oil, or chemical is sprayed inside the door. 

  Where thinner is applied. 

3. Storage 

3-1. Do not keep the switch in dusty, humid place and any place where gas may be 

present for example H

2

S, SO

2

, NH

3

, HNO

3

, Cl

2

    3-2. A switch that has been stored for more than six months must be checked again 

before use. 

4. Using the release key    (See Figure 1) 

    4-1. The release key is used to open a lock in the case of power failure or 

emergency. 

    4-2. Turn the release key from the LOCK position to the UNLOCK position to 

release the lock. This can open the safety door. (For the mechanical lock type  

only.) 

    4-3.When the release key is turned to the UNLOCK position for maintenance or 

other purposes, make sure to turn it back to the LOCK position before using it. 

    4-4. The set position of the release key at the shipping of the switch is as noted 

below;   

D4SL-N

A : UNLOCK position    D4SL-N

G : LOCK position 

    4-5. While the release key is in the UNLOCK position, a lock is not closed and a 

machine is not activated even when the door is closed in the course of 

preliminary adjustment work performed inside a large machine or a 

depressing type machine. 

    4-6. Do not use the release key when starting or stopping the machine. 

    4-7. The releasing of the auxiliary lock must be handled by an authorized person. 

    4-8. Do not apply an excessive force (of 0.2N m or more) to the threaded portion of 

the release key. The release key may be damaged to the extent that it no 

longer becomes operational. 

    4-9. To avoid an unauthorized person's access to the release mechanism, set the 

release key to the LOCK position, and then seal the release key with a seal 

wax (or wax coatings). 

5. Installing the cover 

    5-1. Confirm that the seal rubber has no abnormality and then use it.   

If the seal rubber is displaced or floated, or if foreign matters adhere to the seal 

rubber, the seal rubber will lose its sealing capability. 

    5-2. Do not use any screw other than correct one, or the sealing capability of the 

seal rubber will deteriorate. 

6. About the hinge type door 

    6-1. A door is mounted near a hinge, excessive load may be imposed beyond a force  

acting on the lock portion of this Equipment. This may result in damage to the  

lock mechanism. Mount it to a position near a handle.  

7. Mounting method 

    7-1. Mounting screw tightening torque loose mounting may result in malfunction.   

Fasten the screws to the specified torque. 

Cover clamping screw 

0.4 to 0.5 N m 

Operation key clamping screw  D4SL-NK G                              

0.75 to 1.15 N m 

Operation key clamping screw   

D4SL-NK ,NK S

       

   

2.4 to 2.8 N m 

Body clamping screw

       

     

0.75 to 1.15N m 

Conduit mounting connection   

1.8 to 2.2 N m (G1/2,M20) 

1.4 to 1.8 N m (1/2-14NPT) 

7-2. Switch, operation key    (See Figure 2) 

1) The switch and operation key will be fastened to specified torque in clause 7-1 

with M4 screws and washers. 

2) The switch can be fastened more firmly by a stud(4mm dia., 1.5mm max height) 

inserted from back side at the hole of the switch. 

3)  Do  not  use  the  operation  key  other  than  dedicated  OMRON’s  (D4SL-NK ). 

Otherwise switch may be damaged. 

4)  Be  sure  that  the  operation  key  can  be  inserted  properly  to  key  hole  with  a 

tolerance of 

±

  0.8mm. 

5) Insert the operation key into the key hole according to the specified  “operation 

key insertion radius in horizontal direction”. 

6) Do not impose excessive force on the key top while the operation key is inserted 

into the switch body or drop the switch with the operation key inserted to avoid 

the deformation of the key or the breakage of the switch body. 

7)  When  mounting  at  the  side  of  switch  body,  mount  the  switch  with  3  points 

including the head.     

8) Attach cap heads to any operation key holes that are not being used. 

9) Do not use the operation key D4SL-K . A lock will not be closed and a machine 

will not be activated. 

7-3. Securing of the door    (See Figure 3) 

1) If the operation key is pulled in the opening direction due to a force caused by  

vibration, by the door weight, or by a cushion attached to the door.  The closed 

door must be secured with a hook or by similar means. 

  7-4. Spacer (See Figure 4) 

      1) Do not remove the spacer. Use the switch with the spacer rotated appropriate 

for the mounting direction. Lock strength will decrease when using the switch 

without spacer. 

8. Wiring 

8-1. Example of circuit connections (See Figure 5) 

1).

 

Internal  circuit  of  the  switch  inside  is  different  according  to  the  part 

number. Please confirm the circuit diagram on the product body when 

using. 

2).  The  open  circuit  operating  contacts  are  labeled  with  arrow  marks.  They  are 

able to used as input to the safety circuit.   

3).

  Please  make  the  system  that  can  observe  both  the  door  open/close 

detection  switch  and  the  lock  monitor  switch  NC  contacts  close  when 

the lock is necessary on safety.   

4). The 24VDC solenoid has a polarity. (E1: Positive (+) polarity, E2:  Negative (-) 

polarity) 

5). Current consumption of the solenoid is different in inrush and constant.  

      Apply the rated working voltage to the solenoid. 

8-2. Wiring    (See Figure 6) 

1). Do not put the electric power when wiring. 

2). Do not let particles such as small piece of lead wire in the switch body when 

wiring. 

3). Adequate conductor size is AWG 24 to 22 (0.2 to 0.3mm

2

).   

Do not pass a current of 2 A or more when using AWG24. 

4). Wire leads as shown in the following figure. Otherwise, the switch cover d oes 

not fit. 

5). Do not pull on lead wires with excessive force. The wires may break.  

6). Do not force    the cable-side socket

 

  into the connector and D4SL-N conduit 

opening. Doing so may break the crimped wires . 

Be sure to insert the cable into the connector and D4SL-N conduit opening first 

and then attach the socket to the cable, or to insert the other end of the cable 

into the connector and the conduit opening. 

 

Cable-side socket 

Manufacturer 

Name 

Type 

J.S.T. 

Housing 

XHP-10 

Contact 

(Applicable Electric Wire AWG24~22) 

SXH-001T-P0.6 

9. Conduit opening 

1). Use the connectors recommended in clause 10 and tighten the connector with 

specified torque in clause 7-1. An excessive torque will bring a case breakage. 

2). When using the connector size of 1/2-14NPT, apply the sealing tape between 

connector and conduit opening so that the enclosure will conform to IP67.   

3). Use a cable with a suitable diameter for the connector.   

10. Recommendation of connector 

For easy wiring, use a connector that has the screw part with 9 mm or less in 

length.         

 

Use below listed connector to secure IP67. 

Size 

Manufacturer 

Type 

Adequate cable 

Diameter 

G1/2 

LAPP 

ST-PF1/2        5380-1002 

6.0 to 12.0 mm 

ACE 

SERVICE 

LS-2 

(Short type) 

6.0 to 11.0 mm 

M20 

LAPP 

ST-M20

×

1.5

 

5311-1020 

7.0 to 13.0 mm 

1/2-14NPT  LAPP 

ST-NPT1/2      5301-6030 

6.0 to 12.0 mm 

Use an optional seal packing (Type: JPK-16 or GPM20). 

Tighten the seal packing to a proper tightening torque.  

LAPP is a German manufacturer.   

Ace Service is a Japanese manufacturer. 

Before a connector of 1/2-14NPT size is used, install a supplied conversion 

adapter on the switch and wrap it in seal tape. 

11. Others 

11-1. Please do a regular check in premeditation for this switch  

12. Technical specification 

Conformity: Machine Directive, Low Voltage Directive, EMC Directive, 

EN1088 EN50047,GS-ET-19 

Approval EN60947-5-1 IEC60947-5-1 UL508 CSA

 

C22.2 No.14 

EN electrical rating 

Utilization category AC-15/DC-13 

Rated Voltage

     

120VAC / 125VDC 

Rated Current

     

1.5A / 0.22A 

UL, CSA electrical rating  

C150                    R150 

Voltage       120VAC                125VDC 

Volt Amp.   Make 1800VA      28VA 

Break 180VA        28VA 

Overvoltage Category     

Direct opening travel (min.) 

15 mm 

Direct opening force (min.) 

60 N 

Holding force (min.)    1300N (GS-ET-19) 

Operating speed 0.05 to 1 m/s 

Operating frequency 5 operation / minute max. 

Conditional short-circuit current    100A 

Short circuit protective device Use 4 A fast acting fuse in accordance with 

                                                              IEC 60127 

Enclosure rating IP67 (EN60947-5-1)    (Operation key insertion face : IP00) 

                                  TYPE 4X INDOOR USE ONLY (UL, CSA) 

Minimum permissible load: 5VDC, 1mA resistive load (N level: reference value) 

Ambient temperature range -10 to +55

 

(Protect against Frost) 

Ambient humidity (max.): 95%RH 

Mechanical durability (min.) 1,000,000 operations 

Electrical durability (min.) 150,000 operations

 

(125VAC,1A resistive load) 

Solenoid   Rated working voltage 24VDC+10%/-15% 

Power-Current consumption  

Inrush 

D4SL-N |N/P/Q/R | 

-

N    Approximately 6.4W-0.27A 

D4SL-N |A/B/C/D/E/F/G/H/S/T/U/V | 

-

Approximately 4.8W-0.2A 

Constant Approximately 2.6W-0.15A (max.) 

Indicator lamp(LED)    Rated voltage 24VDC

 

 

Current consumption Approximately 10mA   

B10d : 2,000,000 

There is no equality between the ON/OFF motions of a contact. 

The  switch  contacts  are  common  use  for  general  load  and  micro  load  but,  after 

switching  a  general  load,  it  is  impossible  to  switch  a  micro  load  with  the  same 

contacts.  The  contact  reliability  would  be  decrease  due  to  the  rough  contact 

surface. 

Liability for use in safety systems 

OMRON  shall  not  be  responsible  for  conformity  with  any  standards,  codes,  or 

regulations that apply to the combination of the products in the 

customer's application or use of the product.     

Take all necessary steps to determine the suitability of the product for the systems, 

machines, and equipment with which it will be used.     

Know and observe all prohibitions of use applicable to this product. 

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS 

RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS 

A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE 

OMRON  PRODUCT  IS  PROPERLY  RATED  AND  INSTALLED  FOR  THE 

INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 

See also Product catalog for Warranty and Limitation of Liability.

 

 

OMRON Corporation Industrial Automation Company 

OMRON EUROPE B.V. 

Wegalaan 67-69-2132 JD Hoofddorp The Netherlands 

Tel: (31)2356-81-300 / Fax: (31)2356-81-388 

OMRON ASIA PACIFIC PTE. LTD. 

No. 438A Alexandra Road # 05-05/08 (Lobby 2),Alexandra Technopark, Singapore 

119967 

Tel: (65) 6835-3011 / Fax: (65) 6835-2711 

OMRON SCIENTIFIC TECHNOLOGIES INC. 

6550 Dumbarton Circle, Fremont CA 94555-3605 U.S.A. 

Tel: (1) 510-608-3400 / Fax: (1) 510-744-1442 

OMRON (CHINA) CO., LTD. 

Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road,PuDong New Area, 

Shanghai, 200120, China 

Tel: (86) 21-5037-2222 / Fax: (86) 21-5037-2200

 

 

Traceability Information 

Representative in EU 

  OMRON EUROPE B.V. 

        Wegalann 67-69 2132 JD Hoofddorp The Netherlands 

Manufacturer 

 

 

OMRON CORPORATION, Safety Device Division 

   

 

Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 JAPAN

 

 

 

 

   

Guard Lock Safety-door Switch 

                        

 

 

           Manvel d’Instrvctions 

  Instruction Sheet    manuale d’Instruzioni 
  Bertriebsanleitung   manuale de Instrucciones 

 

 

 

 

 

 

 

DANGER 

CAUTION 

 

 

 

 

 

 

 

 

 

 

 

Thank you for purchasing this D4SL-N. This INSTRUCTION MANUAL described the information such as 

function, performance and how to use the product required for using the D4SL-N. 

For using this product, please follow keep the precautions as shown in the following: 

 

Ensure  that  this  product  is  installed  and  operated  by  qualified  personal  having  sufficient  skills  in 

mechanics and electrotechnic. 

 

Ensure that you understood this manual and that you use the product as described in this manual. 

 

Keep this instruction manual close at hand and use it for reference during operation. 

EU

EU

www.industrial.omron.eu/safety.

 

Instructions in the official EU languages and a signed EC Declaration of Conformity in English are available on our website at www.industrial.omron.eu/safety. 

2219499-7 A 

1 Fig.1  

3 Fig.3  

5 Fig.5  

6 Fig.6  

2 Fig.2  

M4

Front

4±0.1 dia. 1.5mm high max

22±0.1

41.7±0.15

Side

22±0.1

38.7±0.1

10±0.1

41.7±0.15

M4

4±0.1 dia. 1.5mm high max

D4SL-N

-

N

 

D4SL-N

-

4N

 

LOCK

 

UNLOCK

 

LOCK

 

UNLOCK

 

4 Fig.4  

D4SL-NK3

 

D4SL-NK1G/-NK2G

 

D4SL-NK1/-NK1S/-NK2

 

2-M4

 

15

±

0.1

 

2-M4

 

40

±

0.1

 

2-M4

 

12

±

0.1

 

or  20±0.1

 

Head 

E1
( )

21

33

11

22

34

42

52

51

E2
( )

12

41

64

63

7

3

1

10

8

4

2

9

5

6

for D4SL-N

N

-D

LED

Lock M onitor Switch)

To Safety Circuit

To Control Circuit

To Safety Circuit

Door Open/Close

Detection Switch)

To Control Circuit

E1
( )

21

31

22

32

42

E2
( )

41

62

61

7

3

1

10

8

4

2

9

5

6

for D4SL-N

V

Lock M onitor Switch)

To Control Circuit

To Safety Circuit

Door Open/Close

Detection Switch)

To Control Circuit

AND

(for D4SL-N N

-D N) 

(for D4SL-N V

- N) 

Reviews: