6&($7-3'%"'-84-9#1#"#*$#-:&(.#
Section 1-4
$'
Power Supply
Characteristics
The power supplied to the Unit, to feed the Digital Outputs, has to be supplied
externally and should be a double insulated class II (over-voltage) type with rat-
ings from 12 to 24 VDC (10.2 to 26.4 VDC). Characteristics of the Power Supply
Input circuitry are summarized in the following table.
1-4
Quick Start Up Reference Guide
Operation and
Configuration
Every Counter of the High-speed Counter Unit can be configured as Simple, Cir-
cular or Linear Counter (refer to the next section 1-5
for quick start up information).
Counters configured as Circular/Linear Counter can use all the functions and fea-
tures that the Unit offers to you, while Counters configured as Simple Counter only
offer you a limited subset instead. The diagram below shows you all the functional
blocks that the Unit has available to you to operate and configure the Unit (refer to
).
The numbers in grey refer to the table on page 16
to indicate which functions are supported for Simple Counters and which functions
for Circular/Linear Counters.
Item
Specification
Operating Voltage Range
10.2-26.4 VDC
Current Consumption
30 mA max. (load current excluded)
Internal Fault Protection
Two 1A (not replaceable) internal fuses in Power Supply lines
Reverse Polarity Protection
Yes
Capture
Register
Preset
Register
Programmable
Output Pulse
Output State
Control
Hysteresis
NPN/PNP
Digital Outputs
(O0, O1, O2, O3)
Time-Window
Simple
Circular
Linear
Counter*
1, 2, 3, 4
Noise Filter
Counter Inputs
(A, B, Z)
Digital Inputs
(I0, I1, I2, I3)
I0
I1
I2
I3
1
3
11
9
10
4
4
5
8
6
2, 3
2, 3
2, 3
2, 3, 7
* Diagram is valid for every Counter 1, 2, 3 and 4
Automatic
Output Control
Manual
Output Control
Counter
Reset
Counter
Start/Stop
Rate History
Log File
Rate
Measurement
W902-E2-03.book Seite 14 Donnerstag, 7. Oktober 2004 2:06 14
Summary of Contents for CS1W-CT021
Page 1: ...OPERATION MANUAL High speed Counter Units CS1W CT021 CS1W CT041 Cat No W902 E2 03...
Page 3: ...W902 E2 03 book Seite iv Donnerstag 7 Oktober 2004 2 06 14...
Page 5: ...W902 E2 03 book Seite vi Donnerstag 7 Oktober 2004 2 06 14...
Page 39: ...W902 E2 03 book Seite 24 Donnerstag 7 Oktober 2004 2 06 14...
Page 59: ...A 2 Section 2 3 W902 E2 03 book Seite 44 Donnerstag 7 Oktober 2004 2 06 14...
Page 155: ...4 Section 4 6 W902 E2 03 book Seite 140 Donnerstag 7 Oktober 2004 2 06 14...
Page 199: ...G W902 E2 03 book Seite 184 Donnerstag 7 Oktober 2004 2 06 14...