15
Specifications and Configurations
Section 1-2
is 32 (node addresses 1 to 32). The total number of words that can be
transmitted in a data link is 32,000 words max.
3.
CX-Net in CX-Programmer can be used in systems with up to 32 nodes
(node addresses 1 to 32). Use Controller Link Support Software (Ver. 2.00
or later) or CX-Net in CX-Programmer (Ver. 3 or later) for systems with up
to 62 nodes (node addresses 1 to 62). Refer to Appendix A Standard Mod-
els for information on CX-Net.
4.
CS-series, CVM1, and CV-series PLCs do not have an LR Area, and words
LR000 to LR199 are automatically converted to CIO 1000 to 1199 for use.
5.
Duplex operation of Communications Units is possible only for the CS1W-
CLK12-V1 or CS1W-CLK52-V1 mounted to a CS1D PLC in token-ring
mode.
1-2-5
Controller Link Unit Models and PLCs
Note
1.
When connecting an Optical Ring Controller Link Unit (CS1W-CLK12/12-
V1 or CVM1-CLK12/12-V1) to an Optical Bus Controller Link Unit/Board
(model number ending with CLK11), the Optical Ring Controller Link Unit
must be set to token-bus mode and the transmission path must be con-
nected by the daisy-chain method.
2.
The CS1W-CLK12-V1 and CS1W-CLK52-V1 can only be used in duplex
operation if they are mounted to a CS1D System. For details, refer to CS-
series Duplex System Operation Manual (W405).
Item
Specifications
Type
Optical Bus
Optical Ring (H-PCF)
Model
CS1W-CLK11
CS1W-CLK12-V1
CVM1-CLK12
External
appearance
Installation
devices
---
---
---
Applicable
PLC
CS-series PLCs
CS-series PLCs
CVM1 and CV-series PLCs
Duplex oper-
ation
Not supported
Supported (in CS1D System)
Not supported
Weight
199 g (Not including fittings.)
246 g (Not including fittings.)
437 g (Not including fittings.)
Current con-
sumption
470 mA
520 mA
520 mA
Summary of Contents for CS1W-CLK12-V1
Page 3: ...iv ...
Page 5: ...vi ...
Page 9: ...x TABLE OF CONTENTS ...
Page 11: ...xii ...
Page 59: ...42 Component Names and Functions Section 3 1 Dimensions Unit mm ...
Page 62: ...45 Component Names and Functions Section 3 1 Dimensions Unit mm ...
Page 91: ...74 CVM1 and CV series Optical Ring Controller Link Units Section 4 2 ...
Page 108: ...91 Setting Data Links Section 5 2 Device Information Setting Data Link Tables ...
Page 125: ...108 Checking Data Link Status Section 5 4 ...
Page 181: ...164 Setting Routing Tables Section 7 4 ...
Page 199: ...182 Memory Areas Related to Duplex Operation Section 8 6 ...
Page 275: ...258 Handling Precautions Section 10 7 ...
Page 298: ...281 CS series Optical Bus Controller Link Units Appendix C Dimensions Unit mm 101 35 130 ...
Page 299: ...282 CS series Optical Bus Controller Link Units Appendix C ...