![Omron CP1L-EL20DR-D Operation Manual Download Page 705](http://html1.mh-extra.com/html/omron/cp1l-el20dr-d/cp1l-el20dr-d_operation-manual_743755705.webp)
671
Appendix C
Auxiliary Area Allocations by Function
Initial Settings
CPU Unit Settings
DM Initial Value Settings
Name
Address
Description
Access
Updated
IOM Hold Bit
A500.12
Turn this bit ON to retain the status of the I/O Memory when shift-
ing from PROGRAM to RUN or MONITOR mode or vice versa or
when turning ON the power supply.
ON: I/O memory retained
OFF: I/O memory not retained
Read/write
Forced Status Hold
Bit
A500.13
Turn this bit ON to preserve the status of bits that have been
force-set or force-reset when shifting from PROGRAM to MONI-
TOR mode or vice versa or when turning ON the power supply.
Read/write
Name
Address
Description
Access
Updated
Status of DIP
Switch Pin 3
A395.12
The status of pin 3 on the DIP switch on the front of the CPU Unit
is written to this flag every cycle.
Read-only
Manufacturing Lot
Number
A310 and
A311
The manufacturing lot number is stored in 5 digits hexadecimal.
X, Y, and Z in the lot number are converted to 10, 11, and 12,
respectively.
Examples:
Lot number 23805
A310 = 0823, A311 = 0005
Lot number 15X05
A310 =1015, A311 = 0005
Read-only
Name
Address
Description
Access
Updated
DM Initial Values
Flag
A345.04
ON when DM initial values are stored in the flash memory.
Read-only
DM Initial Values
Read Error Flag
A751.11
ON when an error occurred in transferring DM initial values from
the DM initial value area in flash memory to the DM Area.
Read-only
DM Initial Values
Save Execution
Error Flag
A751.12
ON when the DM Initial Values Transfer Password (A752) is
incorrect or when the DM Initial values area was not specified
when starting to transfer DM initial values from the DM Area to
the DM initial value area in flash memory.
Read-only
DM Initial Values
Save Error Flag
A751.13
ON when an error occurred in transferring DM initial values from
the DM Area to the DM initial value area in flash memory.
Read-only
DM Initial Values
Save Flag
A751.14
ON while DM initial values are being transferred from the DM
Area to the DM initial value area in flash memory.
OFF when the transfer has been completed.
Read-only
DM Initial Values
Save Start Bit
A751.15
Turn ON this bit to start transferring DM initial values. This bit is
valid only when a correct password is stored in A752 and the DM
Area Initial Value Area is specified (i.e., when A753.00 is ON).
The system will turn this bit OFF automatically when the transfer
has been completed.
Read/Write
DM Initial Values
Transfer Password
A752
Set the passwords here to transfer DM initial values between the
DM area and the DM initial value area in flash memory. The
transfer will not be started unless the correct password is set.
The transfer is started when A751.15 is turned ON.
The password will be cleared by the system when the transfer
has been completed.
A5A5 hex: Save initial values from DM to flash
Read/Write
DM Initial Values
Save Area Specifi-
cations
A753.00
Specifies the area to be transferred to flash memory.
Read/Write
Summary of Contents for CP1L-EL20DR-D
Page 3: ...CP1L EL20D CP1L EM30D CP1L EM40D CP1L EL EM CPU Unit Operation Manual Produced July 2017...
Page 4: ...iv...
Page 10: ...x...
Page 22: ...xxii...
Page 34: ...xxxiv Software Licenses and Copyrights 7...
Page 192: ...158 Trial Operation and Debugging Section 5 3...
Page 250: ...216 Automatic Clock Adjustment and Specifying Servers by Host Name Section 6 7...
Page 666: ...632 Trouble Shooting Section 11 7...
Page 696: ...662 Standard Models Appendix A...
Page 805: ...771 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 806: ...772 Connections to Serial Communications Option Boards Appendix F...
Page 836: ...802 PLC Setup Appendix G...
Page 838: ...804 TCP Status Transitions Appendix H...
Page 840: ...806 Ethernet Network Parameters Appendix I...
Page 842: ...808 Buffer Configuration CP1L EL EM Appendix J...
Page 844: ...810 Ethernet Specifications Appendix K...
Page 851: ...Index 817 work words 118 write protection 447...
Page 852: ...818 Index...
Page 854: ...820 Revision History...
Page 855: ......