E3NW-CRT
User’s Manual
Section 3
Part Names
■
Indicators
The following table describes the indicators.
●
Normal Indicator Status
■
Switches
●
Rotary Switches
The E3NW-CRT automatically uses the same baud rate as the CompoNet master. There is no need
to set the baud rate on a rotary switch.
Indicator
Name
Indicator
color
Status
Description
MS
Module status
Green
Lit
Normal operation
Flashing
Not set up.
Red
Lit
Fatal error
Flashing
Non-fatal error
---
OFF
Power OFF
NS
Network status
Green
Lit
CompoNet online and communications connected.
Flashing
CompoNet online but not-connected.
Red
Lit
CompoNet fatal communications error
Flashing
CompoNet non-fatal communications error
---
OFF
CompoNet offline and power OFF.
SS
Sensor
communications
status
Green
Lit
Communications with Sensor Amplifier Unit are
normal.
Red
Lit
Number of Sensor Amplifier Units is inconsistent.
---
OFF
Waiting for communications with the Sensor
Amplifier Units and power OFF.
MS
Lit green when the Unit is normal.
NS
Lit green when network is normal (online and connected).
SS
Lit green when communicating with a Sensor Amplifier Unit.
CompoNet node address setting
Sets the CompoNet node address.
Range: 00 to 62 in I/O Mode 1, or 00 to 58 in I/O Mode 2 (Cannot be set to between 63 and 99.)
Operating Mode Setting
Sets the operating mode. The data that is allocated in the master I/O
area depends on the operating mode. Refer to CompoNet Remote I/O
Communications on page 42 for details.
I/O mode
Operating mode setting
Number of connectable Sensors
1
Mode for using explicit communications to monitor the
detection levels and make settings.
15 max.
2
Mode for using the I/O command area to monitor detection
levels and make settings.
16 max.