146
SE
C
T
ION 7
Ind
ic
a
to
rs an
d Er
ror Chec
k Fl
owc
h
art
s
RFID System
User's Manual
SECTION 7
Troubleshooting Alarms and Errors
Indicators and Error Check Flowcharts
Status Indicators
If an alarm or error occurs in the ID Sensor Unit, the ERC indicator or ERH indicator will light on the
Unit's front panel.
Indicator
Name
Color
Meaning
RUN
RUN
Green
Lit
The ID Sensor Unit is operating normally.
Not lit
The ID Sensor Unit is stopped.
ERC
(Error in Controller)
Unit error
Red
Lit
An error has occurred in the ID Sensor Unit.
Not lit
No error has occurred in the ID Sensor Unit.
ERH
(Error at CPU Unit)
CPU Unit error
Red
Lit
An error has occurred in the CPU Unit.
Not lit
No error has occurred in the CPU Unit.
ERP
(Antenna Power Error)
Antenna power
error
Red
Lit
An error has occurred in the power supply to the Antenna.
Not lit
The power supply to the Antenna is normal.
HEAD1
(Antenna
1)
T/R
Communicating
Yellow
Lit
Communications are active.
Not lit
Communications not being performed with the RF Tag.
NORM/ERR
Normal end
Green
Lit
Communications with the RF Tag ended normally.
Not lit
The indicator is not Iit in all other cases.
Error end
Red
Lit
Communications with the RF Tag ended in an error.
Not lit
The indicator is not Iit in all other cases.
HEAD2
(Antenna
2)
T/R
Communicating
Yellow
Lit
Communications are active.
Not lit
Communications not being performed with the RF Tag.
NORM/ERR
Normal end
Green
Lit
Communications with the RF Tag ended normally.
Not lit
The indicator is not Iit in all other cases.
Error end
Red
Lit
Communications with the RF Tag ended in an error.
Not lit
The indicator is not Iit in all other cases.
V680C11
RUN
ERC
T/R
NORM/ERR
ERP
ERH
V680C12
RUN
ERC
HEAD1
T/R
NORM/ERR
ERP
ERH
HEAD2
T/R
NORM/ERR
V680C11
RUN ERC
ERP ERH
T/R
NORM/ERR
V680C12
RUN ERC
ERP ERH
HEAD1
HEAD2
T/R
NORM/ERR
T/R
NORM/ERR
CS1W-V680C11
CJ1W-V680C11
CS1W-V680C12
CJ1W-V680C12
Summary of Contents for CJ1W-V680C11