![Omron CJ1W- ECT21 Operation Manual Download Page 99](http://html1.mh-extra.com/html/omron/cj1w-ect21/cj1w-ect21_operation-manual_742071099.webp)
5 - 7
5 Troubleshooting
CJ-series EtherCAT Slave Units Operation Manual (W541)
5-2 T
ro
uble
sho
otin
g w
ith
Ind
icato
rs
5
5-
2-1 C
hecking for Er
rors and T
rou
bleshooting with the In
dicators
Errors Related to CPU Unit Data Exchange During Init State or Pre-Opera-
tional State
Error Descriptions
Indicator
Error
Cause
Unit operation
Error
log
(hex)
CIO
area
Countermea-
sures
ECAT
RUN
ECAT
ERR
ERC ERH RUN
Not
Lit
Not
Lit
Not
Lit
Lit
Not
Lit
Unit Num-
ber Dupli-
cation
The same unit
number is set on
another Unit.
Operation
stops and error
is recorded in
the error log.
0006
---
Set the unit num-
bers correctly
and restart the
EtherCAT Slave
Unit.
CPU Unit
Faulty
---
000F
Replace the CPU
Unit if the error
recurs after
restarting the
CPU Unit.
I/O Table
Not Regis-
tered
The CPU Unit’s
I/O table is not
registered.
0006
Create the I/O
table.
Not
Lit
Not
Lit
Lit
Lit
CPU Unit
Faulty
---
Operation
stops
---
Replace the CPU
Unit if the error
recurs when the
CPU Unit is
restarted.
FS
Not
Lit
EtherCAT
Slave Unit
Faulty
Replace the
EtherCAT Slave
Unit if the same
error recurs
when the Unit is
mounted to
another CPU
Unit.
Summary of Contents for CJ1W- ECT21
Page 1: ...Cat No W541 E1 02 OPERATION MANUAL SYSMAC CJ Series CJ1W ECT21 EtherCAT Slave Unit ...
Page 8: ...CONTENTS 6 CJ series EtherCAT Slave Units Operation Manual W541 ...
Page 30: ...Revision History 28 CJ series EtherCAT Slave Units Operation Manual W541 ...
Page 32: ...Sections in this Manual 30 CJ series EtherCAT Slave Units Operation Manual W541 ...
Page 148: ...Appendices A 34 CJ series EtherCAT Slave Units Operation Manual W541 ...
Page 149: ...I 1 I CJ series EtherCAT Slave Units Operation Manual W541 Index ...
Page 152: ...I 4 CJ series EtherCAT Slave Units Operation Manual W541 Index ...
Page 153: ......