![Omron CJ1W-CTL41-E Operation Manuals Download Page 111](http://html1.mh-extra.com/html/omron/cj1w-ctl41-e/cj1w-ctl41-e_operation-manuals_741969111.webp)
Error codes
Section 5-2
94
Error History Log File
Up to a maximum of 30 errors can be logged in chronological order inside the
Counter Unit, constituting the Error History Log File. If multiple errors are active at
the same time every error (-code) can be read sequentially into CIO (n+15, n+16)
by using the Read Next Error bit. Every next error is read from the Error History
Log File at the rising edge of the Read Next Error bit. If you attempt to read an
error after the last error in the list has been read, the value of zero will be returned.
Now you can scroll through the same error list again from the next rising edge of
the Read Next Error bit.
5-2-1
DM-configuration errors
DM-configuration errors are detected during initialisation after the Unit has been
powered up or restarted. DM-configuration errors can also be detected after the
IOWR-instruction “(Re) Configure Unit” has been issued (refer to section 4-5-3-4
“(Re) Configure Unit”
). In case a DM-configuration error is detected the Unit will
report the error and stop operating. The error(s) can be read in CIO using the “Read
Next Error” bit.
General Setting:
n+1
Read Next Error
0
→
1 = Read Next Error
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Error Code 1
Error Code 2
Error
Description
0300
Offset (BCD)
Out of Range
The DM-setting located at
(Nx100) + Offset
is
Out of Range (N = Machine Number).
0310
Offset (BCD)
Invalid BCD-code
The DM-setting located at
(Nx100) + Offset
is
an invalid BCD-code (N = Machine Number).
(The range of a valid BCD-code for a digit is
0-9. If one or more digits is within range A-F an invalid
BCD-code is specified).
0311
Offset (BCD)
Invalid Initial Counter
Value
The Initial Counter Value located at
(Nx100) +
Offset
is outside the counting range that is set for that
Counter (N = Machine Number).
0320
Counter
No.
Range
No.
(BCD)
Invalid
Range Limits
Upper Range Limit < Lower Range Limit.
Counter No.
indicates the Linear Counter number and
Range No.
indicates the Range number.
0330
Counter
No.
Range
No.
(BCD) /
CV No.
(BCD)
Invalid
Range Limit(s) /
Comparison Value
If the Unit is in Range Mode: Lower and/or Upper Range
Limit is/are outside Counting Range.
Counter No.
indicates the Counter number and
Range No.
indicates
the Range number.
If the Unit is in Comparison Mode: Comparison value is
outside Counting Range.
Counter No.
indicates the
Counter number and
CV No.
indicates the Comparison
Value number.
(The counting range of Circular and Linear Counters can
be specified, refer to section 3-2-1
and
for more information).
0331
Counter
No.
CV No.
(BCD)
Comparison Values
are equal
For the Counter, with the
Counter Number
as reported in
Error Code 2, one or more Comparison Values are equal.
CV No.
indicates the Comparison Value number.