English

Eespañol

10 series Blood Pressure Monitor

Model BP786CANN

Instruction Manual

Product includes:

HEM-7321T-CA_A_M.pdf

10 series Blood Pressure Monitor

Model BP786CANN

Instruction Manual

Quick Start Guide

Guide de démarrage rapide

BP786CANN

Battery Set

Juego de Pilas

Summary of Contents for BP786CANN

Page 1: ...English Fran ais 2298848 9B 10 series Blood Pressure Monitor Model BP786CANN Instruction Manual...

Page 2: ...Tensiom tre Adaptateur CA Guide de l utilisateur Brassard ComFit English Eespa ol 10 series Blood Pressure Monitor Model BP786CANN Instruction Manual Product includes HEM 7321T CA_A_M pdf Quick Start...

Page 3: ...1 2 b c d b a A L M H...

Page 4: ...lay Symbols 5 1 2 Before Taking a Measurement 6 2 Preparation 7 2 1 Battery Installation 7 2 2 Using the AC adapter 8 2 3 Setting the TruReadTM Mode 10 2 4 Setting the Date and Time 11 3 Using the Dev...

Page 5: ...using the device on the arm with an arterio venous A V shunt Do not use the device with other medical electrical ME equipment simultaneously Do not use the device in the area of HF surgical equipment...

Page 6: ...result in incorrect measurement results Do not use a mobile phone or other devices that emit electromagnetic fields near the device except when in use for wireless communications This may result in in...

Page 7: ...er Remove the batteries if the device will not be used for three months or more General Precautions Do not forcibly crease the arm cuff or the air tube excessively Do not press the air tube while taki...

Page 8: ...mbol Systolic blood pressure Diastolic blood pressure Connection symbol Memory full symbol OK symbol Heartbeat symbol Flashes during measurement Date Time display TruReadTM symbol Movement error symbo...

Page 9: ...e irregular heartbeat symbol displays with your measurement results we recommend you consult your physician Follow the directions of your physician Movement Error Symbol The movement error symbol is d...

Page 10: ...king exercising and eating for 30 minutes before taking a measurement Rest for at least 15 minutes before taking the measurement 2 Stress raises blood pressure Avoid taking measurements during stressf...

Page 11: ...ry symbol appears on the display turn the monitor off then replace all batteries at the same time Long life alkaline batteries are recommended The measurement values continue to be stored in memory ev...

Page 12: ...The power unit AC Adapter is intended to be correctly oriented in a vertical or floor mount position NOTES Use only the authorized OMRON AC Adapter that came with this monitor We recommend you install...

Page 13: ...ug into the AC adapter jack on the rear side of the monitor 2 Plug the AC adapter into an electrical outlet To disconnect the AC adapter unplug the AC adapter from the electrical outlet first and then...

Page 14: ...ult 1 Select your USER ID 1 or 2 2 Press the button The TruReadTM symbol appears on the display 3 To set the date and time proceed to section 2 4 If the date and time are correct press the START STOP...

Page 15: ...and if the device is paired with a smartphone 2 Push or button to change the year Push button to confirm the year and then the month flashes Repeat the same steps to change the month day hour and min...

Page 16: ...with the fabric fastener Notes When you take a measurement on the right arm the air tube will be at the side of your elbow Be careful not to rest your arm on the air tube The blood pressure can differ...

Page 17: ...room temperature Avoid bathing drinking alcohol or caffeine smoking exercising or eating 30 minutes before taking a measurement Sit on a chair with your feet flat on the floor Sit upright with your b...

Page 18: ...2 Using the Single Mode 1 Select your USER ID 1 or 2 2 Press the START STOP button The arm cuff starts to inflate automatically If your systolic pressure is more than 210 mmHg After the arm cuff start...

Page 19: ...lt in its memory It will automatically turn off after 2 minutes Note Wait 2 3 minutes before taking another measurement Waiting between measurements allows the arteries to return to the condition prio...

Page 20: ...terval will appear on the display The second measurement is complete waiting to start the next measurement The interval will appear on the display The third measurement is complete the average for the...

Page 21: ...e display turns off The arm cuff will start to inflate automatically DO NOT adjust medication based on measurement results from this blood pressure monitor Take medication as prescribed by your physic...

Page 22: ...he average will be based on these 2 values If there is 1 measurement value in the memory for that period this is displayed as the average If the memory is full the monitor will delete the oldest value...

Page 23: ...es stored in the memory To view the older values To view the more recent values Note The value with the TruReadTM symbol is the average for the consecutive 3 measurements To display the individual mea...

Page 24: ...D 1 or 2 2 Press and hold the button for more than 3 seconds Notes If the previous measurement was taken without setting the date and time the average value is not calculated If there are no measureme...

Page 25: ...tphone and follow set up and pairing instructions Note Please make sure that you do not currently have an active reading screen on If your reading screen is on press the START STOP button to clear the...

Page 26: ...monitor will automatically turn off without any operations The date and time settings of your smartphone will automatically sync with the device when paired When Err appears refer to Connection failur...

Page 27: ...more than 10 minutes 1 Open the app on your smartphone 2 Clear your reading screen by pressing the START STOP button on your monitor Next tap the transfer icon in the Omron Wellness app to start the t...

Page 28: ...ore than 5 seconds 2 Release the button and START STOP button when CLr appears on the display The CLr will appear on the display when your monitor has been initial setting 3 Press the START STOP butto...

Page 29: ...eleted by USER ID 1 Select your USER ID 1 or 2 2 Press the Memory button while the memory symbol appears 3 While holding the button down press the START STOP button for more than 3 seconds Note You ca...

Page 30: ...bited On aircraft In hospitals While abroad Make sure that the power has been off before starting the instructions below 1 Press and hold the connection button for more than 10 seconds 2 Release the b...

Page 31: ...been off before starting the instructions below 1 Press and hold the connection button for more than 10 seconds 2 Release the button when ON appears on the display 3 Press the START STOP button to tur...

Page 32: ...n 3 3 If this error continues to appear contact your physician Movement during measurement Carefully read and repeat the steps in section 3 3 The batteries are low You should replace the batteries wit...

Page 33: ...te the arm cuff manually until it is 30 to 40 mmHg above your previous measurement result Refer to section 3 3 The arm cuff was inflated exceeding the maximum allowable pressure and then deflated auto...

Page 34: ...thin 16 ft 5 m of the monitor The Bluetooth function on the destination device is turned off Turn the on the Bluetooth function and try sending the data again The Bluetooth function on the monitor is...

Page 35: ...not wash the device and any components or immerse them in water Do not use gasoline thinners or similar solvents to clean the device Use a soft and dry cloth or a soft and moistened cloth and neutral...

Page 36: ...he arm cuff Note Do not bend or crease the air tube excessively Do not store the device in the following situations If the device is wet Locations exposed to extreme temperatures humidity direct sunli...

Page 37: ...33 5 Maintenance and Storage EN 5 3 Optional Medical Accessories Arm Cuff Arm circumference 9 17 22 42 cm AC Adapter ComFitTM Cuff CFX WR17 Model HEM FL31 HEM ADPTW5...

Page 38: ...INPUT AC100 240V 50 60Hz 0 12A Battery life Approximately 1000 measurements using new alkaline batteries Operating temperature humidity 50 F to 104 F 10 C to 40 C 15 to 90 RH Storage temperature humi...

Page 39: ...pment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or m...

Page 40: ...e operation of other devices or relocate this Product before using this Product or do not use this Product around the other wireless devices The Bluetooth Smart word mark and logos are registered trad...

Page 41: ...and handling fee Enclose the original printed receipt Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in trans...

Page 42: ...essary the medical device should be observed to verify normal operation in the configuration in which it will be used Refer to further guidance below regarding the EMC environment in which the device...

Page 43: ...5 1 kV line s to line s 2 kV line s to earth 1 kV line s to line s 2 kV line s to earth Mains power quality should be that of a typical commercial and or hospital environment Voltage dips short inter...

Page 44: ...gths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment...

Page 45: ...communications equipment Output Power of Transmitter in Watt Separation distance according to frequency of transmitter in meter 150 kHz to 80 MHz d 1 2 80 MHz to 800 MHz d 1 2 800 MHz to 2 5GHz d 2 3...

Page 46: ...N Q P O R W K L G I H J AD M Y X V AA AB AC Z T U S E H G A D B F C...

Page 47: ......

Page 48: ...LTHCARE Co Ltd 53 Kunotsubo Terado cho Muko Kyoto 617 0002 JAPAN Distributed by Distribu par OMRON HEALTHCARE INC 1925 West Field Court Lake Forest IL 60045 U S A omronhealthcare ca 2015 OMRON HEALTHC...