Knob-type Selector Switch

 

A165S/W

G-59

Push

bu

tto

n

Switch

es

Knob-type Selector Switch

A165S/W

Mounting Aperture of 16 mm

• Modular construction

• Oil-resistant IP65 models

• UL and cUL approved.

• Conforms to EN60947-5-1, IEC947-5-1

• Short mounting depth, less than 28.5 mm below panel

• Wide range of switching capacity from standard to microload

• Lighted and non-lighted models

• 2 and 3-notch models

• Manual and automatic reset models

Model Number Structure

Model Number Legend

Completely Assembled

The model numbers used to order sets of Units are illustrated below. One set comprises the Selector, Lamp (lighted models only), and Switch.

(1)

(2)

(3)

(4)

S

W

(5)

(6)

J

A

T

BA

2M

2A

3M

3A

3MA

3AM

R

G

Y

1

2

1P   

2P

2S

24D

A 1 6 5 W - A 2A R - 24D - 1

(1)   Lighted/Non-lighted

Symbol    

Type

Non-lighted

Lighted

(2)   Shape of Selector

Symbol    

Shape

Rectangular

Square

Round

(3)   Number of Notches/Resetting Method

Symbol

Manual

Automatic

Manual

Automatic

CCW-manual,

CW-automatic

CCW-automatic,

CW-manual

2 notches

3 notches

(4)   Color of Selector

Symbol    

Color

Red

Green

Yellow

(6)   Contact Configuration

Symbol Type 

Terminal

SPDT   

DPDT   

SPDT   

DPDT   

DPDT

(5)   Light Source

Symbol Type

24-V LED

Reset method

No. of notches

Voltage Reduction Unit (24-V Built-in LED)

LED

Symbol

Type

No symbol

No symbol

Non-lighted

Square

  

(24-mm square)

Black  
(non-lighted 
models only)

Screw-Less 
Clamp

PCB 
terminal

Solder 
terminal

Note: 1. 

Only DPDT contacts are availa-
ble with 3-notch models and 
Screw-Less Clamp models.

2.

 PCB terminals are available 

only with 2-notch models.

Note: 1. 

Solder terminals are only available with 100-V 
models.

2.

 The Voltage Reduction Unit is not available for 

models with PCB terminals.

T1 

90 to 121 VAC/VDC 

110 VAC/VDC

T2 

180 to 242 VAC/VDC 

220 VAC/VDC

Rated 
voltage

Operating voltage

Summary of Contents for A165S -

Page 1: ...ighted 2 Shape of Selector Symbol Shape Rectangular Square Round 3 Number of Notches Resetting Method Symbol Manual Automatic Manual Automatic CCW manual CW automatic CCW automatic CW manual 2 notches 3 notches 4 Color of Selector Symbol Color Red Green Yellow 6 Contact Configuration Symbol Type Terminal SPDT DPDT SPDT DPDT DPDT 5 Light Source Symbol Type 24 V LED Reset method No of notches Voltag...

Page 2: ... notches 3AM 3 notches 4 Illumination Color None Black Non lighted models only R Red G Green Y Yellow 2 Switch Same as for Key type Selector Switches 1 Number of Notches 2N 2 notches 3N 3 notches 2 Contacts 1 SPDT 2 DPDT 3 Lighted Non lighted None Non lighted L Lighted 4 Terminals None Solder terminals tab terminals 110 3 Lamp 1 Operating Voltage Rated Voltage LED 5DS 5 VDC 5 VDC 12DS 12 VDC 12 VD...

Page 3: ... No of notches Output Reset method Lighting method Operating voltage Model 2 notches SPDT LED 24 VDC A165W J2M 24D 1 Non lighted A165S J2M 1 LED 24 VDC A165W J2A 24D 1 Non lighted A165S J2A 1 DPDT LED 24 VDC A165W J2M 24D 2 Non lighted A165S J2M 2 LED 24 VDC A165W J2A 24D 2 Non lighted A165S J2A 2 3 notches DPDT LED 24 VDC A165W J3M 24D 2 Non lighted A165S J3M 2 Manual Automatic Manual Automatic M...

Page 4: ...No of notches Output Reset method Lighting method Operating voltage Model 2 notches SPDT LED 24 VDC A165W T2M 24D 1 Non lighted A165S T2M 1 LED 24 VDC A165W T2A 24D 1 Non lighted A165S T2A 1 DPDT LED 24 VDC A165W T2M 24D 2 Non lighted A165S T2M 2 LED 24 VDC A165W T2A 24D 2 Non lighted A165S T2A 2 3 notches DPDT LED 24 VDC A165W T3M 24D 2 Non lighted A165S T3M 2 Manual Automatic Manual Automatic Ma...

Page 5: ...s can be created using individual Units Also store the parts as spares for maintenance and repairs Lamp Lighted Models Non lighted Models Selector Switch LED only Solder terminals no transformer Lighted non lighted Lighted non lighted PCB terminals Selectors with Knobs Rectangular Models Square Models Round Models Note Temperature rises in incandescent lamps can cause heat deformation ...

Page 6: ...165W A3A Non lighted A165S A3A 3 notches LED 24 VDC A165W A3MA Non lighted A165S A3MA LED 24 VDC A165W A3AM Non lighted A165S A3AM 2 notches Manual LED 24 VDC A165W T2M R red Y yellow G green Non lighted A165S T2M LED 24 VDC A165W T2A Non lighted A165S T2A 3 notches Manual LED 24 VDC A165W T3M Non lighted A165S T3M LED 24 VDC A165W T3A Non lighted A165S T3A 3 notches LED 24 VDC A165W T3MA Non ligh...

Page 7: ...s Panel Plugs Rectangular A16ZJ 3003 Used for covering the panel cutouts for future panel expansion Degree of protection IP40 Square A16ZA 3003 Round A16ZT 3003 Name Appearance Model Applicable types Remarks Pushbutton Switch Knob type Selector Switch Key type Selector Switch Emergency Stop Switch Indicator Screw Fit ting A16Z 3004 Yes Yes Yes Yes Yes Convenient for ganged installation Tighten to ...

Page 8: ...esistor 5 VDC 30 mA 15 mA 5 VDC 5 33 Ω 68 Ω 12 VDC 15 mA 12 VDC 5 270 Ω 560 Ω 24 VDC 10 mA 24 VDC 5 1600 Ω 2 000 Ω Item Knob type Selector Switch Allowable operating frequency Mechanical 20 operations minute max Electrical 10 operations minute max Insulation resistance 100 MΩ min at 500 VDC Dielectric strength 1 000 VAC 50 60 Hz for 1 min between terminals of same polarity 2 000 VAC 50 60 Hz for 1...

Page 9: ...0 5 mm2 0 75 mm2 1 25 mm2 Solid wire 0 5 mm dia 0 8 mm dia 1 0 mm dia Tensile strength 10 N 20 N 30 N 40 N Length of exposed wire 10 1 mm Type Features Knob type Selector Switch 2 notches 3 notches Operating force OF max 9 8 N m Set position SP 90 5 45 10 0 Two notches Three notches 2 FP Free Position Note 1 The angle used for automatic reset is shown in parentheses Name Contact SPDT COM NC NO SW2...

Page 10: ...5 T Rectangular A165 J Terminal Type Protective Structure Oil resistant IP65 Lighting Method Selector Switch Lamp PCB terminals Solder terminals tab terminals 110 Standard Loads 5 A at 125 VAC 5 A at 250 VAC 3 A at 30 VDC Minimum applicable load 1 mA at 5 VDC 3 Notches Manual reset Automatic reset 2 Notches Manual reset Automatic reset Non lighted models Lighted LED models The upper face of the kn...

Page 11: ...nals 110 Solder terminals tab terminals 110 Note See page 14 for panel cutouts Note See page 14 for panel cutouts Note See page 14 for panel cutouts Lamp terminal Packing t0 5 Lock ring Mounting nut Model standard lot No serial number Lamp terminal Model standard lot No serial number Packing t0 5 Lock ring Mounting nut Lamp terminal Model standard lot No serial number Lock ring Mounting nut Packin...

Page 12: ...Note See page 14 for panel cutouts Lamp terminal Packing t0 5 Lock ring Mounting ring Direction indication arrow Selector Lock ring Mounting ring Switch Case Switch dismounting lever Lock ring Mounting ring Rectangular A165 J Rectangular A165W T Reduced voltage light ing solder terminals tab terminals 110 Packing t0 5 for oil resistant IP65 only Rectangular A165 2S Packing t0 5 for oil resistant I...

Page 13: ...ngement Bottom View Note The L is not shown on the Switch Dimensions of Terminal Holes Terminal Arrangement Bottom View Note The L is not shown on the Switch Dimensions of Terminal Holes Side with TOP indicated Terminal Arrangement Bottom View Dimensions of Terminal Holes Side with TOP indicated Terminal Arrangement Bottom View Lighted SPDT Switches Lighted DPDT Switches Lamp terminal t 0 5 Side w...

Page 14: ...ted Three 1 dia Two 5 dia Side with TOP indicated Six 1 dia Two 5 dia Dimensions of PCB Terminals Model rating and lot number indication Terminal Arrangement Bottom View PCB Cutouts Bottom View Dimensions of PCB Terminals PCB Cutouts Bottom View Top View Top View Note 1 Make sure the thickness of the mounting panel is 0 5 to 3 2 mm 2 If the panel is to be finished with coating etc make sure that t...

Page 15: ...cautions section for the A16 Top View Top View 24 min 24 min 16 0 2 dia 0 24 min 25 min Recommended panel thickness 0 5 to 3 2 mm 25 min Recommended panel thickness 0 5 to 3 2 mm Rectangular A165 J Square A165 A Round A165 T Rectangular A165W T Rectangular A165 2S 16 0 2 dia 0 16 0 2 dia 0 33 min Dimension A 16 0 2 dia 0 23 min Dimension A Note 1 Ensure that the variation in the distance between t...

Page 16: ... interest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No A125 E1 02 ...

Reviews: