background image

7 series

Blood Pressure Monitor

with ComFit

TM

Cuff

Model

BP760

INSTRUCTION MANUAL

ESP

AÑOL

ENGLISH 

Summary of Contents for 7 series BP760

Page 1: ...7 series Blood Pressure Monitor with ComFitTM Cuff Model BP760 INSTRUCTION MANUAL ESPAÑOL ENGLISH ...

Page 2: ...tions Know Your Unit 9 Unit Display 11 Display Symbols 12 Irregular Heartbeat Symbol 12 Movement Error Symbol 12 Morning Hypertension Symbol 13 Heartbeat Symbol 14 Average Value Symbol 14 Morning Average Symbol 14 Evening Average Symbol 14 Cuff Wrap Guide Symbol 14 Using the AC Adapter 15 Battery Installation 17 Setting the Date and Time 19 Applying the Arm Cuff 23 TABLE OF CONTENTS ...

Page 3: ...2 Morning and Evening Averages 33 Morning Averages 33 Evening Averages 33 To Display Morning and Evening Averages 34 Display Combinations 35 To Delete All Values Stored in the Memory 36 Care and Maintenance Care and Maintenance 37 Error Indicators and Troubleshooting Tips 39 FCC Statement 41 Limited Warranties 42 Specifications 43 TABLE OF CONTENTS 3 ...

Page 4: ...ood s movement through your brachial artery and converts the movements into a digital reading An oscillometric monitor does not need a stethoscope so the monitor is simple to use The BP760 comes with the following components Monitor ComFitTM Cuff AC Adapter Storage Case Instruction Manual printed in English and Spanish Quick Start Guide The BP760 IntelliSense Automatic Blood Pressure Monitor is in...

Page 5: ...tact your physician for specific information about your blood pressure Self diagnosis and treatment using measured results may be dangerous Follow the instructions of your physician or licensed healthcare provider DO NOT adjust medication based on measurement results from this blood pressure monitor Take medication as prescribed by your physician Only a physician is qualified to diagnose and treat...

Page 6: ...ising where the cuff is applied Operate the device only as intended Do not use the device for any other purpose Dispose of the device components and optional accessories according to applicable local regulations Unlawful disposal may cause environmental pollution Do not use a cellular phone near the device It may result in an operational failure Use only Omron authorized parts and accessories Part...

Page 7: ...E AND MAINTENANCE Do not subject the monitor to strong shocks such as dropping the unit on the floor Do not submerge the device or any of the components in water Store the device and the components in a clean safe location Changes or modification not approved by Omron Healthcare will void the user warranty Do not disassemble or attempt to repair the unit or components SAFETY INFORMATION 7 ...

Page 8: ... your arm on a table so that the cuff is at the same level as your heart 6 Remain still and do not talk during the measurement 7 Wait 2 3 minutes between measurements The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement You may need to increase the wait time depending on your individual physiological characteristics 8 Keep a record of your blo...

Page 9: ...9 KNOW YOUR UNIT Main Unit Air Jack Battery Compartment Start Stop Button Morning Evening Average Button Memory Button Display AC Adapter Jack Operating Instructions Up Down Buttons SET Button ...

Page 10: ...nents Arm Cuff Air Tube Air Plug Connects to Air Jack AC Adapter Storage Case Housing Cord 7 series Blood Pressure Monitor with ComFitTM Cuff Model BP760 INSTRUCTION MANUAL ESPAÑOL ENGLISH Quick Start Guide Instruction Manual ...

Page 11: ...isplay Memory Number Date Time Display Low Battery Indicator Deflation Symbol Morning Average Symbol Heartbeat Symbol Irregular Heartbeat Symbol Evening Average Symbol Average Value Symbol Memory Symbol Morning Hypertension Symbol Week Display Blood Pressure Level Indicator Cuff Wrap Guide ...

Page 12: ...etected while the monitor is measuring the systolic and diastolic blood pressure If the irregular heartbeat symbol displays with your measurement results we recommend you consult your physician Follow the directions of your doctor MOVEMENT ERROR SYMBOL The Movement Error Symbol is displayed if you move your body during the measurement Please remove the arm cuff and wait 2 3 minutes Take another me...

Page 13: ...ant women and patients with renal failure1 The monitor is not intended to be a diagnostic device MORNING HYPERTENSION SYMBOL The Morning Hypertension Symbol is displayed if the morning average reading for a week is above 135 for the Systolic Blood Pressure value and or 85 for the Diastolic Blood Pressure value when viewing the Morning Averages and the Evening Averages in the memory Omron Healthcar...

Page 14: ...reading appears on the display screen MORNING AVERAGE SYMBOL The Morning Average symbol is displayed when viewing Morning Averages using the Memory Function EVENING AVERAGE SYMBOL The Evening Average symbol is displayed when viewing Evening Averages using the Memory Function CUFF WRAP GUIDE SYMBOL When the cuff is applied correctly is displayed while taking a measurement or using the memory functi...

Page 15: ...urement results will not be deleted CAUTION Use only Omron authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit USING THE AC ADAPTER 15 DANGER TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK CAREFULLY FOLLOW THESE INSTRUCTIONS For connection to a power supply not in the U S A use an attachment plug adapter of the proper configuration for the ...

Page 16: ...t 60 cycles TO DISCONNECT THE AC ADAPTER Hold the Housing to remove the AC Adapter from the electrical outlet Remove the AC Adapter plug from the monitor WARNING Do not plug or unplug the power cord into the electrical outlet with wet hands CAUTION Do not overload power outlets Plug the device into the appropriate voltage outlet USING THE AC ADAPTER 16 Housing Cord ...

Page 17: ...k up while pushing it in the direction of the arrow 2 Install 4 AA size batteries so the positive and negative polarities match the polarities of the battery compartment as indicated 3 Replace the battery cover BATTERY INSTALLATION 17 Battery Cover ...

Page 18: ... replacing the batteries If the batteries are removed while the unit is still on the date and time will be reset to that of the previous use However the measurement results are not deleted When the batteries are replaced you may need to reset the date and time If appears on the display refer to page 19 Setting the Date and Time The supplied batteries may have a shorter life CAUTION Dispose of the ...

Page 19: ...e dates and times The monitor also calculates weekly averages for measurements in the morning and in the evening Morning and Evening averages are stored for this week and the last seven weeks The monitor can also calculate an average reading based on the three most recent measurements taken within 10 minutes of the last reading NOTE If only two readings are stored in the memory for the 10 minute p...

Page 20: ...ay reaches 2040 it will return to 2010 Press the Up button to advance by increments of one year Press the SET button to set the current year The month flashes on the display NOTES Press the Down button to decrease the date and time values by decrements of one Press and hold the Up or Down button to increase or decrease the date and time values faster SETTING THE DATE AND TIME 20 ...

Page 21: ...on to advance by increments of one month Press the SET button to set the current month The day flashes on the display 4 SETTING THE DAY Press the Up button to advance by increments of one day Press the SET button to set the current day The hour flashes on the display ...

Page 22: ... of one hour Press the SET button to set the current hour The minute flashes on the display 6 SETTING THE MINUTE Press the Up button to advance by increments of one minute Press the SET button to set the minute setting 7 TO TURN THE MONITOR OFF Press the START STOP button SETTING THE DATE AND TIME ...

Page 23: ...is intended for use in measuring blood pressure and pulse rate in the adult population Do not use this device on infants or persons who cannot express their intentions APPLYING THE CUFF ON THE LEFT ARM 1 Make sure the air plug is securely inserted in the main unit 2 Remove tight fitting clothing from your upper left arm APPLYING THE ARM CUFF 23 ...

Page 24: ...lat on the floor Place your left arm on a table so the cuff is level with your heart 4 Hold the thumb grip on the cuff securely with your right hand 5 Turn the palm of your left hand upward APPLYING THE ARM CUFF Thumb Grip Cloth Fastener ...

Page 25: ...r arm and aligned with your middle finger The air tube runs down the inside of your arm The bottom of the cuff should be approximately 1 2 above your elbow 7 Wrap the cuff firmly in place around your arm using the cloth fastener APPLYING THE ARM CUFF 1 2 inch 1 2 cm Air Tube Blue Stripe ...

Page 26: ...on page 25 Apply the cuff to your right upper arm so the thumb grip is centered on the inside of your inner arm The bottom of the cuff should be approximately 1 2 above your elbow NOTE Be careful not to rest your arm on the air tube This will restrict the flow of air to the cuff APPLYING THE ARM CUFF 26 Thumb Grip ...

Page 27: ...ured results may be dangerous Follow the instructions of your physician or licensed healthcare provider CAUTION Operate the device only as intended Do not use the device for any other purpose CUFF WRAP GUIDE This monitor checks whether the arm cuff is applied correctly during the inflation When the cuff is applied correctly is displayed while taking a measurement or using the memory function If th...

Page 28: ...inflation Do not move your arm and remain still until the entire measurement process is completed NOTE To stop the inflation or measurement press the START STOP button The monitor will stop inflating start deflating and will turn off 2 Inflation stops automatically and the measurement is started As the cuff deflates decreasing numbers appear on the display The Heartbeat Symbol flashes at every hea...

Page 29: ...nformation about your blood pressure Self diagnosis and treatment using measured results may be dangerous Follow the instructions of your physician or licensed healthcare provider WARNING DO NOT adjust medication based on measurement results from this blood pressure monitor Take medication as prescribed by your physician Only a physician is qualified to diagnose and treat High Blood Pressure WARNI...

Page 30: ...ssure is known to be more than 220 mmHg press and hold the START STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure NOTES Do not apply more pressure than necessary The monitor will not inflate above 299 mmHg When the measurement is complete the arm cuff completely deflates Your blood pressure and pulse rate are displayed ...

Page 31: ...Averages and 8 weeks of Evening Averages AVERAGING FUNCTION The monitor calculates the average reading based on the three most recent sets of measurement values taken within 10 minutes of the most recent reading NOTES If two sets of measurement values are stored in the memory for the 10 minutes period the average is based on the two sets of measurement values If one set of measurement values is st...

Page 32: ...surement values on the screen The values are displayed from the most recent to the oldest NOTE The date and time are alternately displayed with the measurement values Press the Up or Down button to display the next set of values To the older readings To the more recent readings NOTE Press and hold the Up or Down button to display the values faster USING THE MEMORY FUNCTION 32 Alternating display ...

Page 33: ...s of Morning Averages and 8 weeks of Evening Averages NOTE The week begins Sunday at 4 00 AM MORNING AVERAGES Morning averages are based on the first reading Measurement times must be between 4 00 AM and 9 59 AM EVENING AVERAGES Evening averages are based on the last reading Measurement times must be between 7 00 PM and 1 59 AM USING THE MEMORY FUNCTION 33 ...

Page 34: ...ess the Down button to display the previous weeks With each press of the Down button the values are displayed from 1 week ago to the older With each press of the Up button the values are displayed from 7 week ago to the recent NOTE If no measurement is taken in a given week the display will appear as illustrated 3 Press the START STOP button to turn the monitor off USING THE MEMORY FUNCTION 34 ...

Page 35: ...surement results these may be displayed in the following combinations Display Average above AHA guidelines Morning Hypertension Average within AHA guidelines Morning Average Evening Average Morning average from This Week with Morning Average Symbol Morning average from 7 weeks ago with Morning Average Symbol Morning Hypertension Symbol Evening average from This Week with Evening Average Symbol Eve...

Page 36: ... when the Evening Average is displayed regardless of the values for the Evening Average TO DELETE ALL VALUES STORED IN THE MEMORY You cannot partially delete values stored in the memory All values will be deleted 1 While holding the Memory button and the START STOP button simultaneously for more than 2 seconds all values will be deleted USING THE MEMORY FUNCTION ...

Page 37: ...he monitor with a soft dry cloth Do not use any abrasive or volatile cleaners Do not attempt to clean the cuff CAUTION Do not submerge the device or any of the components in water Do not subject the monitor to extreme hot or cold temperatures humidity or direct sunlight CAUTION Store the device and the components in a clean safe location CAUTION Do not subject the monitor to strong shocks such as ...

Page 38: ...ification not approved by Omron Healthcare will void the user warranty Do not disassemble or attempt to repair the unit or components CAUTION Use only Omron authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit CARE AND MAINTENANCE 38 ...

Page 39: ...main still and do not talk during measurement Refer to Taking a Measurement If E2 appears repeatedly inflate the cuff manually until it is 30 to 40 mmHg above your previous measurement result Refer to Taking a Measurement The arm cuff was inflated above 299 mmHg when inflating the cuff manually Do not inflate the cuff above 299 mmHg Refer to Taking a Measurement Movement during measurement Repeat ...

Page 40: ...es Check the battery installation for proper placement of the battery polarities Measurement values appear too high or too low Blood pressure varies constantly Many factors including stress time of day and how you wrap the cuff may affect your blood pressure Review the sections Before Taking a Measurement and Taking a Measurement TROUBLESHOOTING TIPS ...

Page 41: ...y one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the product and the receiver Connect the product into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does...

Page 42: ...urn shipping and handling fee Enclose the Proof of Purchase Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit Because of possible loss in transit we recommend insuring the product with return receipt requested THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN CONNECTION WITH THIS PRODUCT AND OM...

Page 43: ... with 4 new alkaline batteries Operating Temperature 50ºF to 104ºF 10ºC to 40ºC 15 to 90 RH Humidity Storage Temperature 4ºF to 140ºF 20ºC to 60ºC 10 to 95 RH Humidity Air Pressure 700 1060 hPa Main Unit Weight Approximately 15 1 8 oz 430 g not including batteries Main Unit Dimensions Approx 6 1 4 l 4 7 8 w 3 5 16 h 158 mm 124 mm 86 mm Cuff Size Approximately 6 w 152 mm Cuff tube 23 5 8 l 600 mm C...

Page 44: ...Manufactured by OMRON HEALTHCARE Co Ltd Made in China Distributed by Omron Healthcare Inc 1200 Lakeside Drive Bannockburn IL 60015 www omronhealthcare com Copyright 2010 Omron Healthcare Inc ...