185
Preparing and Mounting Flat Connectors on the Cables
Section E-4
E-4-2
Preparing Connectors for Flat Cable I
Preparing and
Mounting the DCN4-
TR4 Flat Connector
Sockets
Names of Flat Connecter Socket components
Cover
Housing
1.
Cutting the Cable (required only when the cable is extended or when a
Terminating Resistor is connected)
At the tip of the cable, cut the cable perpendicular to the cable length.
To prevent short-circuiting, use a sharp cutting tool such as a nipper. After
cutting, confirm that there is no remaining wire coming out.
2.
Setting the Cable Stopper (required only when the cable is extended or
when a Terminating Resistor is connected)
For extending cables or connecting a Terminating Resistor, the cable can end
within the Connector. Thus place a cable stopper in advance.
Close the cover of the Flat Connector I Socket. Secure the hook. Press down
the cable stopper until it clicks into place and does not return.
Cable confirmation slot
Black
Cable labels (Black,
blue/green, white, and red)
Cable stopper