background image

New Product

1

Single-phase Overvoltage/Undervoltage Relay

K8AK-VW

Ideal for Voltage Monitoring for 
Industrial Facilities and Equipment.

• Monitor for overvoltages and undervoltages simultaneously.

Separate settings and outputs supported for overvoltages and 
undervoltages.

• Manual resetting and automatically resetting supported by one 

Relay.

• Pre-alarm Monitoring Mode.
• Two SPDT output relays, 5 A at 250 VAC (resistive load).
• Process control signal (0 to 10 V) and current splitter input 

supported.

• Output status can be monitored using LED indicator.
• Input frequency of 40 to 500 Hz supported.
• Inputs are isolated from the power supply.

Ordering Information

List of Models

Ratings and Specifications

Input Range

* The range is selected using connected terminals.

Refer to 

Safety Precautions

 on page 9.

Refer to page 8 for commonly asked questions.

For the most recent information on models that have been certified for 
safety standards, refer to your OMRON website.

Setting range

Power supply voltage

Model

1 to 10 V AC/DC

3 to 30 V AC/DC

15 to 150 V AC/DC

24 VAC/DC

K8AK-VW2 24 VAC/DC

100 to 240 VAC

K8AK-VW2 100-240 VAC

20 to 200 V AC/DC

30 to 300 V AC/DC

60 to 600 V AC/DC

24 VAC/DC

K8AK-VW3 24 VAC/DC

100 to 240 VAC

K8AK-VW3 100-240 VAC

Model

Range*

Connection terminal

Setting range

Input impedance

Overload capacity

K8AK-VW2

0 to 10 V AC/DC

V1-COM

1 to 10 V AC/DC

3 to 30 V AC/DC

15 to 150 V AC/DC

Approx. 120 k

Ω 

Continuous input at 115% of 
maximum input.

10 s at 125%

(up to 600 VAC)

0 to 30 V AC/DC

V2-COM

Approx. 320 k

Ω

 

0 to 150 V AC/DC

V3-COM

Approx. 1.6 M

Ω

K8AK-VW3

0 to 200 V AC/DC

V1-COM

20 to 200 V AC/DC

30 to 300 V AC/DC

60 to 600 V AC/DC

Approx. 1.2 M

Ω

0 to 300 V AC/DC

V2-COM

Approx. 1.7 M

Ω

0 to 600 V AC/DC

V3-COM

Approx. 3.1 M

Ω

Summary of Contents for 378174

Page 1: ...afety Precautions on page 9 Refer to page 8 for commonly asked questions For the most recent information on models that have been certified for safety standards refer to your OMRON website Setting ran...

Page 2: ...stive load 5 A at 250 VAC 5 A at 30 VDC Maximum switching capacity 1 250 VA 150 W Minimum load 5 VDC 10 mA reference values Mechanical life 10 million operations min Electrical life 5 A at 250 VAC or...

Page 3: ...4 CCC GB T 14048 5 Insulation resistance 20 M min Between all external terminals and the case Between all power supply terminals and all input terminals Between all power supply terminals and all outp...

Page 4: ...is no relay output during timer operation V1 21 V2 V3 24 22 11 12 14 A1 A2 C A1 A2 Single phase power supply Load Power supply voltage Power supply AC DC t t1 t Delay 250 ms reference value Delay 250...

Page 5: ...tes 1 and 2 Terminal block See notes 1 and 2 Item Meaning Power indicator PWR Green Lit when power is being supplied Relay status indicator RY Yellow Lit when relay operates Not light when both AL1 an...

Page 6: ...perating mode are set using the DIP switch located on the bottom of the Unit Model Setting range Wiring connection K8AK VW2 1 to 10 V AC DC V1 COM 3 to 30 V AC DC V2 COM 15 to 150 V AC DC V3 COM K8AK...

Page 7: ...sing Input Terminal V3 COM The maximum setting range will be 600 VAC VDC and the setting range will be 60 to 600 V Operating Time The operating time is set using the operating time knob T The operatin...

Page 8: ...nnection Diagram How to Measure the Operating Time Overvoltage Change the input suddenly from 0 to 120 of the set value and measure the time until the Unit operates Undervoltage Change the input sudde...

Page 9: ...9 N m Use of the product beyond its life may result in contact welding or burning Make sure to consider the actual operating conditions and use the product within its rated load and electrical life co...

Page 10: ...rely and become difficult to see 15 Do not use the product if it is accidentally dropped The internal components may be damaged 16 Be sure you understand the contents of this catalog and handle the pr...

Page 11: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Page 12: ...A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Tokyo JA...

Reviews: