background image

Environment Sensor 

Environment Sensor

User’s Manual 

A278-E1-01

2JCIE-BL01

Summary of Contents for 2JCIE-BL01

Page 1: ...Environment Sensor Environment Sensor User s Manual A278 E1 01 2JCIE BL01...

Page 2: ...20 2 2 7 Sound Noise Characteristics UUID 0x3018 21 2 2 8 Discomfort index Characteristics UUID 0x3019 22 2 2 9 Heat stroke Characteristics UUID 0x301A 23 Control Service Service UUID 0x3030 24 2 3 2...

Page 3: ...ual A278 2 3 Advertise format 35 A Beacon 36 3 1 B Connection Advertise 1 37 3 2 3 2 1 Advertise ADV_IND 37 3 2 2 Scan Response SCAN_RSP 38 C Connection Advertise 2 ADV_IND 39 3 3 D Sensor ADV 1 ADV_I...

Page 4: ...s Communication I F Manual applies to Environment Sensor type 2JCIE BL01 Communication Interface 1 2 Environment sensor communicates with a smartphone tablet etc via Bluetooth low energy Table 1 GAP R...

Page 5: ...ther they are connected or disconnected to from the Central device Further details of Beacon Mode are described in 3 Advertise format Initialize Time information Timer Sensor Measurement Data Recordin...

Page 6: ...ding Table 2 List of Beacon Mode with Data Recording Beacon Mode Name Shortened Device Name Device Name 0x00 Event Beacon SCAN RSP Env EnvSensor BL01 0x01 Standard Beacon Env EnvSensor BL01 0x07 Alter...

Page 7: ...TIME When data is stored 13 times from Row 0 to Row 12 in single page a new page is created for the next measurement Table 4 Example of Memory contents Page 1 Items Contents Remarks UNIX TIME 0x5685C1...

Page 8: ...cs are based on the same Base UUID as follows Base UUID 0C4CXXXX 7700 46F4 AA96D5E974E32A54 Table 6 List of supported GATT Services Service UUID Service name Number of Characteristics 0x3000 Sensor Se...

Page 9: ...for the sensor data acquisition Table 7 List of Characteristics in Sensor Service Characteristics UUID Characteristics Properties Byte R W N I 0x3001 Latest data 19 0x3002 Latest page 9 0x3003 Request...

Page 10: ...t 1 In the operation with data recording mode the value is always zero unless Time information is set 2 Discomfort Index Heatstroke risk factor WBGT approximation are calculated only by temperature an...

Page 11: ...past memory data by referring to the difference between the page information at the previous data retrieving and this latest page information Table 9 Latest page format Byte Field Format Contents 0 UN...

Page 12: ...g Row No UInt8 Range 0 12 2 1 4 Response flag Characteristics UUID 0x3004 When requesting page and row number is set in 2 1 3 Request page 2 1 5 Response Data will be updated with retrieved measured d...

Page 13: ...of this Characteristic However since automatic retrieving across pages is not performed when moving to the next page it is necessary to specify the page number again to 2 1 3 Request page and confirm...

Page 14: ...Response flag until updating is completed 3 If the result of reading Response flag is 0x02 Fail and updating is not completed after 3 times of retry the data in the flash memory may be corrupted In t...

Page 15: ...se previous 1 Relative Humidity UInt8 2 Light UInt8 3 UV Index UInt8 4 Barometric Pressure UInt8 5 Sound noise UInt8 6 Discomfort Index UInt8 7 Heatstroke risk factor UInt8 8 Other events UInt8 Bit 7...

Page 16: ...ify measurement interval in seconds Common to all sensors Time information is cleared to zero 0 when changing the measurement interval so it is necessary to set the time again to start data recording...

Page 17: ...fault 0x00 1 Changing trend threshold rise previous L SInt16 Unit 0 01 degC Range 0 01 30 00 degC Default 0x00C8 2 00 degC 2 H 3 Changing trend threshold decline previous L 4 H 5 Changing trend thresh...

Page 18: ...1 Disable 0 Default 0x00 1 Changing trend threshold rise previous L SInt16 Unit 0 01 RH Range 0 01 50 00 RH Default 0x01F4 5 00 RH 2 H 3 Changing trend threshold decline previous L 4 H 5 Changing tren...

Page 19: ...Enable 1 Disable 0 Default 0x00 1 Changing trend threshold rise previous L SInt16 Unit 1 lx Range 1 2000 lx Default 0x00C8 200 lx 2 H 3 Changing trend threshold decline previous L 4 H 5 Changing trend...

Page 20: ...ble 0 Default 0x00 1 Changing trend threshold rise previous L SInt16 Unit 0 01 Range Index 0 00 11 00 Default 0x012C 3 00 2 H 3 Changing trend threshold decline previous L 4 H 5 Changing trend thresho...

Page 21: ...x00 1 Changing trend threshold rise previous L SInt16 Unit 0 1 hPa Range 0 1 200 0 hPa Default 0x0032 5 0 hPa 2 H 3 Changing trend threshold decline previous L SInt16 4 H 5 Changing trend threshold ri...

Page 22: ...0 1 Changing trend threshold rise previous L SInt16 Unit 0 01 dB Range 0 01 50 00 dB Default 0x07D0 20 00 dB 2 H 3 Changing trend threshold decline previous L SInt16 4 H 5 Changing trend threshold ris...

Page 23: ...Disable 0 Default 0x00 1 Changing trend threshold rise previous L SInt16 Unit 0 01 Range 0 01 50 00 Default 0x03E8 10 00 2 H 3 Changing trend threshold decline previous L SInt16 4 H 5 Changing trend t...

Page 24: ...0x00 1 Changing trend threshold rise previous L SInt16 Unit 0 01 degC Range 0 01 30 00 degC Default 0x012C 3 00 degC 2 H 3 Changing trend threshold decline previous L SInt16 4 H 5 Changing trend thres...

Page 25: ...ash memory Time information based on this setting is recorded for each page of the flash memory Note Memory recording of measured data is not started unless time set to this Characteristic Table 26 Ti...

Page 26: ...ensor Bit 3 Error UV sensor Bit 2 Error Light sensor Bit 1 Error Humidity sensor Bit 0 Error Temperature sensor valid only with built in Accelerometer type 1 CPU Status UInt8 Bit 7 2 RFU Bit 1 Boot de...

Page 27: ...cs Contents Properties Byte R W N I 0x3041 UUIDs UUID Major Minor 20 0x3042 ADV setting Advertise setting 10 2 4 1 UUIDs Characteristics UUID 0x3041 Specify UUID to be sent in Beacon Mode Beacon Adver...

Page 28: ...ertise interval L UInt16 Advertise interval Unit 0 625ms Range 0x0320 500ms 0x4000 10 24s Default 0x0808 1285ms 1 H 2 ADV_NONCON_IND Advertise interval L UInt16 Unit 0 625ms Range 0x00A0 100ms 0x4000...

Page 29: ...v EnvSensor BL01 B A B Alternate 0x01 Standard Beacon Env EnvSensor BL01 B 0x02 General Broadcaster 1 IM IM BL01 D 0x03 Limited Broadcaster 1 IM IM BL01 D 0x04 General Broadcaster 2 EP EP BL01 E 0x05...

Page 30: ...UID 0x3050 2 5 Perform Firmware update via BLE communication Table 34 List of Characteristic in DFU Service Attribute UUID Characteristics Properties Byte R W N I 0x3051 DFU Control Point 0x3052 DFU P...

Page 31: ...6E 2 v 0x76 3 S 0x53 4 e 0x65 5 n 0x6E 6 s 0x73 7 o 0x6F 8 r 0x72 9 0x2D 10 B 0x42 11 L 0x4C 12 0 0x30 13 1 0x31 When in Beacon Mode 0x02 0x03 IM BL01 7 Byte When in Beacon Mode 0x04 0x05 EP BL01 7 By...

Page 32: ...04 Connection parameter update is performed 5 seconds after Connection and thereafter 3 times with 30 seconds interval Table 38 Peripheral Preferred Connection Parameters format Byte Field Format Cont...

Page 33: ...String Model Number 10 0x2A25 Serial Number String Serial Number 10 0x2A26 Firmware Revision String Firmware Revision 5 0x2A27 Hardware Revision String Hardware Revision 5 0x2A29 Manufacturer Name St...

Page 34: ...x30 0x39 7 0 9 0x30 0x39 8 0 9 0x30 0x39 9 0 9 0x30 0x39 2 7 3 Firmware Revision String Characteristics UUID 0x2A26 Table 42 Firmware Revision String format Byte Field Format Contents 0 Firmware Revis...

Page 35: ...ensor User s Manual A278 34 2 7 5 Manufacturer Name String Characteristics UUID 0x2A29 Table 44 Manufacturer Name String format Byte Field Format Contents 0 Manufacturer Name Utf8s O 0x4F 1 M 0x4D 2 R...

Page 36: ...ing ADV_IND C Connection Advertise 2 This format contains Flag Local Name Latest page information and event flag There is no SCAN_RSP and sensor data is not included D Sensor ADV 1 This format contain...

Page 37: ...23 18 16 10 0x4C 24 19 17 11 0x30 25 20 18 12 0x00 26 21 19 13 0x77 27 22 20 14 0x00 28 23 21 15 0x46 29 24 22 16 0xF4 30 25 23 17 0xAA 31 26 24 18 0x96 32 27 25 19 0xD5 33 28 26 20 0xE9 34 29 27 21...

Page 38: ...9 7 1 AD Type 0x01 15 10 8 2 Flags 0x06 16 11 9 3 Length 0x03 17 12 10 4 AD Type 0x02 18 13 11 5 0x0A 19 14 12 6 0x18 20 15 13 7 Length 0x04 21 16 14 8 AD Type 0x08 22 17 15 9 E 23 18 16 10 n 24 19 17...

Page 39: ...9 13 Ambient light Evt 27 22 20 14 UV index Evt 28 23 21 15 Pressure Evt 29 24 22 16 Sound noise Evt 30 25 23 17 Discomfort index Evt 31 26 24 18 Heat stroke Evt 32 27 25 19 Misc Evt 33 28 26 20 34 29...

Page 40: ...1 19 13 27 22 20 14 28 23 21 15 29 24 22 16 30 25 23 17 Temperature Evt 31 26 24 18 Relative humidity Evt 32 27 25 19 Ambient light Evt 33 28 26 20 UV index Evt 34 29 27 21 Pressure Evt 35 30 28 22 So...

Page 41: ...8 22 17 15 9 23 18 16 10 24 19 17 11 25 20 18 12 26 21 19 13 27 22 20 14 28 23 21 15 29 24 22 16 30 25 23 17 31 26 24 18 32 27 25 19 33 28 26 20 34 29 27 21 35 30 28 22 36 31 29 23 37 32 30 24 38 33 3...

Page 42: ...18 12 26 21 19 13 27 22 20 14 28 23 21 15 29 24 22 16 30 25 23 17 31 26 24 18 32 27 25 19 33 28 26 20 34 29 27 21 35 30 28 22 36 31 29 23 37 32 30 24 38 33 31 25 39 34 32 26 Battery voltage 40 35 33...

Page 43: ...ters 3 1 2 01 07 2017 Added annotation on Accelerometer 4 1 3 02 03 2017 Corrected a typo 5 1 4 09 12 2017 Added description on event data in Advertise Format Added annotation on Transmission period i...

Page 44: ...1 01 0618 0618 O Americas Europe https www components omron com http components omron eu Asia Pacific China https ecb omron com sg https www ecb omron com cn Korea Japan https www omron ecb co kr http...