Page 1: ...RuggedNet GPoE Mi 4 and 8 Port PoE PoE Fiber Switches USER MANUAL Firmware Release 2 1...

Page 2: ...l List ACL 23 6 1 3 Bandwidth Profile BWP 25 6 1 4 Cable Test CABLETEST 29 6 1 5 Contact CONTACT 30 6 1 6 Class of Service COS 32 6 1 7 File Directory DIR 35 6 1 8 Ethertype ETHERTYPE 36 6 1 9 Load Fi...

Page 3: ...n 96 7 1 2 3 Port Statistic Overview 97 7 1 2 4 Port Statistics Detailed 98 7 1 2 5 SFP Port Info 100 7 1 3 Hardware Configuration Screens 103 7 1 3 1 DIP Switch 103 7 1 3 2 Port Interface Overview 10...

Page 4: ...iew 165 9 2 Save Current Settings 165 9 3 Copy the Files to Your Hard Drive 165 9 5 Update the GPoE Mi 165 9 5 1 Updating the Firmware Using FTP 165 9 5 2 Updating the Firmware Using the Web Interface...

Page 5: ...er When negotiating to PoE IEEE 802 3af it delivers up to 15 4 Watts per RJ 45 port When negotiating to PoE IEEE 802 3at it delivers up to 30 Watts per RJ 45 port 1 1 NEW FEATURES Firmware release 2 1...

Page 6: ...ransceivers The SFP interfaces operate in auto negotiation and support full duplex operation Fixed fiber 1000BASE X connectors are available with multimode MM dual fiber single mode SM dual fiber and...

Page 7: ...ber Port 2 Fiber Ports Function LEFT LEFT Switch Mode factory default Switch Mode factory default LEFT RIGHT Directed Switch Mode Directed Switch Mode RIGHT LEFT Reserved Dual Device Mode Switch Mode...

Page 8: ...ort Two fiber ports models can be configured for Directed Switch Mode and Fiber Redundancy per DIP switches 3 and 4 Traffic is forwarded to both the primary F1 and secondary F2 fiber ports The seconda...

Page 9: ...s configured for Dual Device Mode and Directed Switch Mode the traffic from Ports 1 2 is only forwarded to fiber port F1 and Ports 3 4 are only forwarded to fiber port F2 On the 8 Port models configur...

Page 10: ...1 after the fiber link has been restored for 6 seconds 2 2 3 SW5 MAC Learning MAC Learning Off When this DIP switch is in the MAC Learning position factory default all ports on the module will learn t...

Page 11: ...rrent protection for connection with centralized DC shall be provided in the building installation and shall be a UL listed circuit breaker rated 20 Amps and installed per the National Electrical Code...

Page 12: ...MAY CAUSE SERIOUS INJURY OR DEATH THERE ARE NO USER REPLACEABLE OR SERVICEABLE PARTS IN THIS UNIT WARNING 4 0 CONNECT CABLES a When using SFP models insert the SFP fiber transceiver into the SFP rece...

Page 13: ...Power LED Indicators Fiber Ports LED Indicators Fixed Fiber Models Legend Indicator Description 1000 OFF No link Green ON Port linked at 1000Mbps Green Blinking at 10Hz Port data activity at 1000Mbps...

Page 14: ...at 10Hz Port data activity at 1000Mbps Half duplex 10 100 1000 OFF No link Green ON Port linked at 10Mbps Green Blinking at 10Hz Port data activity at 10Mbps Amber ON Port linked at 10Mbps Half duplex...

Page 15: ...Serial public username admin FTP public username admin Telnet public username admin SNMPv1 v2c Read public Write private SNMPv1 v2c agent enabled User 1 type admin User 1 name admin User 1 password p...

Page 16: ...Mi Copyright 2017 2018 OST Inc Omnitron Systems Technology Technical Support 949 250 6510 38 Tesla Sales Products 800 675 8410 Irvine CA 92618 On the web at www omnitron systems com IP address 192 16...

Page 17: ...ndancy configuration mactable mac table status module module global configuration ping ping configuration port port attribute configuration portaccess port access configuration portstat port statistic...

Page 18: ...Port Based Network Access Control 802 1X AAA is a framework for controlling access to computer resources enforcing policies auditing usage and providing the information necessary to bill for services...

Page 19: ...retry the login sequence depending upon how the TACACS server is configured ERROR An error occurred at some time during the authentication If an ERROR response is received the module will typically t...

Page 20: ...pHostList host1 hostn key server key aKey dflt not defined l4 layer 4 port number list a1 a3 a1 authentication authorization port number 1 65535 a3 accounting port number 1 65535 meth authentication m...

Page 21: ...rt on the module that is associated with the AAA protocol The default is all ports The ptype switch selects the port authentication mode auto configures 802 1X authentication on the port mac configure...

Page 22: ...ed server s authentication Port 1812 accounting Port 1813 key timeout sec 60s number of retries 2 802 1X disabled guest VLAN disabled port F1 tunnel on port F2 tunnel on port 1 tunnel on port 2 tunnel...

Page 23: ...ddrEnd proto arp icmp ip tcp udp ty deny permit dst port Switches a add ACL d delete ACL idx 1 200 dall delete all ACLs dflt default for items not found in ACL list deny permit dflt permit dis disable...

Page 24: ...e configured ACL filters The ty switch selects the ACL access type permit or deny NOTES When an ACL type ty is configured as deny with a protocol proto of IP and the IP range ipsrc is specified the AC...

Page 25: ...wed into the provider s network Bandwidth profiles consist of the following parameters Committed Information Rate CIR CIR specifies the maximum rate Ethernet frames are delivered per service performan...

Page 26: ...F2 1 4 pol policing count type polType l1 l2 l3 dflt is l2 que type of egress queue qType fairweight starving qlist where qlist is q7 q6 q5 q4 q3 q2 q1 q0 where qx is sp or fw sp indicates strict prio...

Page 27: ...e set up individually q7 q6 q5 q4 q3 q2 q1 q0 where qx can be one of two values sp or fw sp Queue is set to strict priority The listing of strict priority queues starts at highest priority queue queue...

Page 28: ...olicing egress cir 1000000kbps L2 policing queue type fairweight egress queue rate kbps q7 q6 q5 q4 q3 q2 q1 q0 1000000 1000000 1000000 1000000 1000000 1000000 1000000 1000000 PCP classification over...

Page 29: ...per port Syntax cabletest h cabletest p pNum Switches h display help information p port number pNum 1 n The options available using the cabletest command are shown below The h switch displays the help...

Page 30: ...selects the name of the normally open relay dflt s show current status The options available using the contact command are shown below The h switch displays the help screen presented above It is stati...

Page 31: ...contact s Digital input status open door alarm open Contact closure output alarm state not activated Contact closure normally open Contact closure normally closed Contact closure output mode none Digi...

Page 32: ...n m modify CoS profile mode mode classification mode cMode ip ipoverl2 l2 l2overip none ip ip only classification ipoverl2 ip classification priority over layer 2 PCP l2 layer 2 PCP classification onl...

Page 33: ...the default CoS classification value of 1 The pcp switch defines the profile based on the PCP bit of the ingress frame The s switch displays the current class of service profiles Class of Service CoS...

Page 34: ...red CoS profiles the ingress traffic will use the default class classification In the example below class of service profile is created cos a cn data pcp 0 1 class 0 cos m cn data pcp 2 3 class 2 cos...

Page 35: ...dir d fileName dir s Switches d delete file fileName h display help information s show available files The options available using the dir command are shown below The d switch deletes a specific file...

Page 36: ...therTypeVal dflt 8100 etherTypeVal selects the EtherType that is used for the selected network type value is entered in hex typical selection for customer networks is 8100 for provider networks 88a8 s...

Page 37: ...dflt app The options available using the fwload command are shown below The d switch deletes a firmware file on the module The f switch selects the firmware file to activate The h switch displays the...

Page 38: ...nable disable dflt enabled gw gateway address gateway h display help information net subnet mask subnet rserv DHCP Relay Server ipAddr rtype DHCP Relay client type tsel drop keep replace dflt replace...

Page 39: ...request 2 The DHCPrelay agent receives the broadcast DHCPrequest packet and inserts the relay agent information option option 82 into the packet The relay agent information option contains related sub...

Page 40: ...F2 1 4 proto protocol configuration pMode discard peer tunnel discard LLDP is disabled LLDP frames are discarded peer LLDP is enabled and protocol is operating tunnel LLDP is disabled LLDP frames are...

Page 41: ...er valid The range is 1 to 10 and the default is 4 The txrt switch configures the transmission frequency of LLDP updates in seconds The range is 5 to 65 534 seconds and the default is 30 seconds NOTES...

Page 42: ...13 f0 Port ID component 1 Time to Live 120 Port Description Port 1 System Name XM5 System Description 9600 40 B1 v5 3 6 s n 00713365 Capabilities Bridge Capabilities enabled Bridge Management Address...

Page 43: ...rded 0 LLDP Port TLVs discarded 0 LLDP Port TLVs unrecognized received 0 LLDP Port Age Outs 0 To tunnel LLDP on all ports use the lldp proto tunnel p all lldp proto tunnel p all lldp s LLDP configurat...

Page 44: ...000000 90 000000 dflt blank long longitude mLong 180 000000 180 000000 dflt blank post postal code zipcode mPost 1 16 ASCII characters dflt blank s shows current configuration state state provide mSta...

Page 45: ...Address 38 Tesla City Irvine State province California Postal zipcode 92618 Latitude Longitude Altitude NOTE When configuring text based names such as 38 Tesla the text name much be in for the comman...

Page 46: ...ndancy dflt ena enable link redundancy h display help information noret no return to working port ret return to working port dflt s show current configuration The options available using the lr comman...

Page 47: ...and display the MAC addresses learned by the module and configure the MAC aging time To display the MAC addresses use the mactable command from the CLI prompt A list of options is displayed when the...

Page 48: ...d clearing the MAC table when the link is down learning global enables or disables MAC learning port enables or disables the clearing of the MAC table when any port link down The h switch displays the...

Page 49: ...ompt string pName 0 to 32 ASCII characters s show current configuration all led env mfg mod The options available using the module command are shown below The bau switch configures the baud rate of th...

Page 50: ...2 Port 2 PSE Act Grn 13 Port 3 100 10 Grn 14 Port 3 1000 10 Off 15 Port 3 PSE Act Grn 16 Port 4 100 10 Off 17 Port 4 1000 10 Grn 18 Port 4 PSE Act Off NOTE The module s led display will vary depending...

Page 51: ...10 Port 2 100 10 Grn 11 Port 2 1000 10 Off 12 Port 2 PSE Act Grn 13 Port 3 100 10 Grn 14 Port 3 1000 10 Off 15 Port 3 PSE Act Grn 16 Port 4 100 10 Off 17 Port 4 1000 10 Grn 18 Port 4 PSE Act Off Mode...

Page 52: ...using the ping command are shown below The h switch displays the help screen presented above It is static and provides help information for the specific command The l switch defines the size of the pi...

Page 53: ...port name portName 1 45 ASCII characters p port list pList F1 F2 1 4 mgt1 all s shows current configuration NOTE Port number selection will vary depending on the model The options available using the...

Page 54: ...port is set to auto negotiation with the following modes advertised 1000FDX When set to 1000 the port is always in AN mode 1000 man hdx Based on the link partner The RJ 45 port is set to auto negotiat...

Page 55: ...ecurity is disabled Port 2 is named Port 2 MTU 10240 bytes Port mode is UTP 1000 AN FDX Linked 1000 FDX no flow Port flow control is disabled Port output is enabled MAC learning is enabled active Port...

Page 56: ...s ena enable port access h display help information p port list pList F1 F2 1 4 all s shows the port access configuration NOTE Port number selection will vary depending on the model The options availa...

Page 57: ...fic command The p switch selects which port statistic is displayed The s switch displays the selected port statistics To display the port statistics for Fiber Port 1 use the portstat s p f1 command po...

Page 58: ...age dflt enabled ip IP protocol dflt enabled serial serial console port dflt enabled telnet Telnet protocol dflt enabled h display help information s show current configuration The options available u...

Page 59: ...e function heartbeat ena enable function heartbeat heartbeat selects heartbeat ping dflt disabled h display help information hdfr heartbeat restart defer in sec iTime 10 300 dflt 60 i heartbeat interv...

Page 60: ...pderr switch configures the number of consecutive lost heartbeats before an error condition is declared The default value is 3 lost heartbeat signals The pdint switch configures the number of times a...

Page 61: ...rt mode auto PD mode status 802 3af Class 2 7W Voltage supplied 56 88V Current supplied 33 20mA Heartbeat disabled Heartbeat IP address 0 0 0 0 Heartbeat interval 1s Heartbeat detection 3 lost respons...

Page 62: ...LI prompt to configure or restart the module Alist of options is displayed when the restart h command is entered restart h Description restart restart module Syntax restart h restart boot back Switche...

Page 63: ...on files The options available using the restore command are shown below The a switch creates a new local configuration file The d switch deletes the current local configuration file The h switch disp...

Page 64: ...t 20000 ppri port priority pPri 0 240 dflt 128 proto protocol configuration pMode discard peer tunnel discard RSTP is disabled BPDU frames are discarded peer RSTP is enabled and protocol is operating...

Page 65: ...d The default Forward Delay is 15 seconds MAC Address Aging bage The time before the MAC address is removed from the MAC table A value from 10 630 seconds is valid The default MAC Aging Time is 300 se...

Page 66: ...Priority 128 Path Cost 20000 Port F2 Configuration Rapid Spanning Tree Tunnel RSTP Port State N A Port Priority 128 Path Cost 20000 Port 1 Configuration Rapid Spanning Tree Tunnel RSTP Port State N A...

Page 67: ...ow The h switch displays the help screen presented above It is static and provides help information for the specific command The s switch displays the current state of the changes made to the module U...

Page 68: ...mation open open script file scriptName osf run execute script file scriptName osf s show current script file list type type the selected file scriptName osf The options available using the script com...

Page 69: ...transfer the selected file The options available using the serupdate command are shown below The h switch displays the help screen presented above It is static and provides help information for the sp...

Page 70: ...age 70 Select the location of the firmware file Updating the firmware using the serial console port can take a very long time Please be patient when updating the firmware using the serial console port...

Page 71: ...t numbers installed p port number pNum F1 F2 s show current status NOTE Port number selection will vary depending on the model The options available using the sfp command are shown below The h switch...

Page 72: ...FF FF FF FF FF FF FF FF FF FF Address A2 Page Contents 00 5A 00 F6 00 55 00 FB 00 92 7C 6B 6C 8A AC 72 10 Z U kl r 10 2A 91 02 8E 25 8F 02 C1 12 54 01 A2 0E 8F 02 0E 0 T 20 94 C7 01 7E 76 2E 02 F9 00...

Page 73: ...fig h Description showconfig show basic configuration information status Syntax showconfig h showconfig s ver Switches h display help information s show current configuration ver verbose show The opti...

Page 74: ...le using the snmp command are shown below The dis switch disables SNMPv1 The ena switch enables SNMPv1 The h switch displays the help screen presented above It is static and provides help information...

Page 75: ...on i time server request interval in minutes iTime 1 60 dflt 8 ip1 time server IP address 1 serverIP ip2 time server IP address 2 serverIP s show current configuration z time zone selection zoneVal To...

Page 76: ...tered splash Description splash splash screen warning message configuration Syntax splash h splash s splash warn wMsg Switches h display help information s show current status warn warning message wMs...

Page 77: ...e the remote devices and allows the remote devices to authenticate the user The module supports SSH Version 2 To configure SSH use the ssh command from the CLI prompt A list of options is displayed wh...

Page 78: ...password plain text and public key authentication methods Password is plain text entered in the client application RSA is a public key generated via the Rivest Shamir and Adleman algorithm and DSA is...

Page 79: ...mber The h switch displays the help screen presented above It is static and provides help information for the specific command The s switch displays the configuration of the DIP switches To enable DIP...

Page 80: ...on p port number pNum F1 F2 1 4 mgt1 rem trunk port remove VLAN ID vlanList 1 4095 all s show current configuration vid vlan id assignment for access tunnel port vlanId 1 4095 NOTE Port number selecti...

Page 81: ...e use the switchport s command switchport s Port F1 is an access port type associated with VLAN ID 1 Port F2 is an access port type associated with VLAN ID 1 Port 1 is an access port type associated w...

Page 82: ...est syslog entry sLevel message sLevel syslog level message 1 to 127 characters The options available using the syslog command are shown below The erase switch erases all the entries in the current sy...

Page 83: ...Status enabled Server IP address 192 168 1 100 Severity logging level Info Facility code 23 Number of local entries 6 Number of entries Debug 0 Info 0 Notice 0 Warning 4 Error 2 Critical 0 Alert 0 Eme...

Page 84: ...ample 12 01 2015 13 10 00 h display help information s show current configuration z time zone zoneVal The options available using the time command are shown below The a switch sets the time of day The...

Page 85: ...he traphost command are shown below The dall switch deletes configured trap hosts and resets the setting to factory default The default setting is 255 255 255 255 The h switch displays the help screen...

Page 86: ...uration ver verbose show The options available using the traps command are shown below The clr switch clears the current trap log entries The dall switch restores all traps to default settings The dis...

Page 87: ...25 PoE status error Enabled Warning 26 PoE status normal Enabled Info 27 ACL access denied Enabled Warning 28 Telnet authentication failure Enabled Warning 29 Telnet session started Enabled Info 30 T...

Page 88: ...er h Description user user configuration Syntax user h user s user lto timeout ato timeout artry count fsto timeout user d name uName dall user a name uName pw uPw sto timeout user m name uName nname...

Page 89: ...r a new user This password is used for Serial FTP Telnet and SSH The s switch displays the user configuration The sto switch configures the session timeout value for a specific user The default timeou...

Page 90: ...ation s show current status The options available using the ver command are shown below The h switch displays the help screen presented above It is static and provides help information for the specifi...

Page 91: ...LAN name vlanName 1 64 ASCII characters The options available using the vlan command are shown below The add switch adds a new VLAN instance The h switch displays the help screen presented above It is...

Page 92: ...st N America UTC 04 hours HNA Heure Normale de l Atlantique N America UTC 04 hours Q Quebec Time Zone Military UTC 04 hours EST Eastern Standard Time N America UTC 05 hours CDT Central Daylight Time N...

Page 93: ...n monitoring of each port The factory default IP address is 192 168 1 220 The web management software provides intuitive and easy to navigate menu options NOTE The Web Interface is compatible with Mic...

Page 94: ...ending on the model Port Status Port Indicates the port designation Port Type Indicates if the port is a fixed fiber SFP or copper port Port Function Indicates if the port is configured as a standard...

Page 95: ...ed Power Supply Status Pwr A Displays a green indication if the power is applied and displays the detected voltage Pwr is displayed on modules with one power input Pwr B Displays a green indication if...

Page 96: ...ature as well as information on uptime and system utilization A Refresh button and Auto Refresh check box is also located at the bottom left corner of the screen Click the Refresh button to update the...

Page 97: ...is located at the bottom left corner of the screen to clear the statistic on the module Click on the Clear Counters button to clear the statistics A Refresh button and Auto Refresh check box is also...

Page 98: ...ed screen displays the number of packets in each queue Receive Rx and Transmit Tx Counters Octets The total number of good bytes of data transmitted received by a port Packets The total number of good...

Page 99: ...that were between 256 and 511 octets in length 512 1023 bytes The total number of packets including bad packets received that were between 512 and 1023 octets in length 1024 max size bytes The total...

Page 100: ...d Use the Page Selection pull down to select the A0 A2 Hexadecimal or A0 A2 Decoded pages to be displayed A Refresh button and Auto Refresh check box is also located at the bottom left corner of the s...

Page 101: ...Vendor Name Vendor OUI Vendor Part Number Vendor Revision Number Vendor Serial Number Vendor Date Code Wavelength nm Options Diagnostic Monitoring Type Enhanced Options SFF 8472 Compliance A Refresh...

Page 102: ...h Low Alarm Vcc High Low Warning Bias High Low Alarm Bias High Low Warning Tx Power High Low Alarm Tx Power High Low Warning Rx Power High Low Alarm Rx Power High Low Warning A Refresh button and Auto...

Page 103: ...led software override active option Click on the Apply button to activate the changes Once the Global Setting has been changed to DIP switches disabled software override active the soft switch DIP swi...

Page 104: ...4 Protection mode models with 2 fiber ports only No redundant fiber factory default Redundant fiber no return to primary Redundant fiber return to primary 5 MAC Learning MAC learning enabled factory d...

Page 105: ...ber ports will vary depending on the model Port Indicates the port designation Port Type Indicates if the port is a fixed fiber SFP or copper port Link Displays the state of the link green or amber Gr...

Page 106: ...en disabled on a RJ 45 port the connected PD will remain powered but data access is disabled PoE State Use the PoE State pull down menu to configure the PoE PSE for the selected port The options are P...

Page 107: ...h the attribute to change the parameter General Port State Use the Port State pull down menu to configure the port for negotiation speed and duplex Port Name Use the text box to enter a name for the p...

Page 108: ...run the cable test on the selected port Once completed the results of the cable test is displayed Click on the Apply button to activate the changes Click the Save button to permanently save the chang...

Page 109: ...the Heartbeat Lost Before Error text box to enter a new value for the number of lost heartbeats A value of 1 to 100 is a valid entry The Heartbeat Lost Before Error configures the number of consecutiv...

Page 110: ...in Input Name Enter a name for the alarm input in the text box Input Pin Displays the status of the alarm input input open or input closed An alarm input is available for detecting external events suc...

Page 111: ...en either an alarm input or input power alarm is detected Temperature An error condition is declared when a temperature violation is detected Input Temperature An error condition is declared when eith...

Page 112: ...r the module FTP Use the FTP pull down menu to enable or disable FTP FTP will need to be enabled for any firmware updates FTP is disabled by default Telnet Use the Telnet pull down menu to enable or d...

Page 113: ...text box to enter the file name of the SSL TLS certificate Location Location Name Use the Location Name text box to enter a name of the location of the installation Address City State Province Postal...

Page 114: ...the x x x x format x represents a decimal number between 0 and 255 Class A subnet mask is 255 0 0 0 Class B subnet mask is 255 255 0 0 and Class C subnet mask is 255 255 255 0 IPv4 Gateway Enter the...

Page 115: ...ys DHCP messages between DHCP clients and DHCP servers A DHCP relay agent receives any DHCP broadcasts and forwards them to the specified DHCP server IP address 1 The DHCP client generates a DHCP requ...

Page 116: ...2c is enabled Trap Host 1 8 Enter the IP Address of the Trap Host in the text box in the x x x x format SNMP traps are used to report events that occur during the operation of a network and may requir...

Page 117: ...Page 117 Use the Instance Selection pull down menu to select the global or port settings Select SNMPv1 v2c Settings Click the Modify button to change the Read or Write Community Names...

Page 118: ...e text box again Write Community The SNMP Write Community Name is necessary for writing SNMP set data to the module The name can be a combination of 1 32 alphanumeric character string private is the d...

Page 119: ...g the web interface Use the pull down menus associated with each item to make changes to the Time of Day Date and Time Zone Click the Copy Local Time button to use the time and date of the local works...

Page 120: ...me between server requests A value of 1 to 60 minutes is a valid entry The default is 8 minutes Time Server 1 IPAddress Enter the IP Address of the time server in x x x x format in the text box Time S...

Page 121: ...ngs Select Global Global Configuration Normal Transmission Interval s Sets the transmission frequency of LLDP updates in seconds The range is 5 to 32 768 seconds and the default is 30 seconds Enter th...

Page 122: ...nserted Indicates the number of times the information advertised has been inserted into tables Number of Times Table Data Deleted Indicates the number of times the information advertised has been dele...

Page 123: ...rent status of the system LLDP does not have a mechanism for soliciting specific information from other LLDP agents Use the LLDPMode pull down menu to select the operating mode as Transmit Only Receiv...

Page 124: ...tion is Included or Not Included in the LLDPDU System Capabilities TLV Provides the system capabilities of the module i e Bridge Switch SVLAN CVLAN Use the System Capabilities pull down menu to select...

Page 125: ...the text box Delete Check the box and click the Delete button to delete the VLANs Use the text boxes on the NEW entry row to add a new VLAN ID Click in the VLAN ID text box and enter a VLAN number Cli...

Page 126: ...Page 126 Click the Save button to permanently save the changes...

Page 127: ...nfigured as a trunk Port Indicates the port designation Port Type Use the Port Type pull down menu to configure the port as a trunk tunnel or access port Trunk When configured as a trunk port Ingress...

Page 128: ...on a trunk port is untagged Untagged traffic received on a trunk port is assigned to the VLAN associated with the native VLAN When the port is configured as a trunk port use the Native VLAN text box...

Page 129: ...rvice performance objectives These frames are referred to as being in profile green Use the CIR text box to enter a new value in kb sec A value of 64 to 1 000 000 is a valid entry The default is 1 000...

Page 130: ...a valid entry The default is 1 000 000 Policing Use Policing pull down menu to select whether bandwidth profiles are counted based upon L1 frame interframe gap preamble L2 only or L3 only Queue Type...

Page 131: ...Egress Ingress Egress or Egress Queues Select Ingress Ingress Rate Port Indicates the port designation CIR Committed Information Rate Use the CIR text box to enter a new value in kb sec A value of 64...

Page 132: ...he changes Click the Save button to permanently save the changes Use the Selection pull down menu to select Ingress Egress Ingress Egress or Egress Queues Select Egress Egress Rate Shaping Port Indica...

Page 133: ...st priority queue queue 7 and can only be selected from the highest queue sequentially without mixtures of weighted values between strict priority queues fw The queue is set to fairweight priority The...

Page 134: ...ss Queues Egress Queue Rates Port Indicates the port designation Q7 Q0 Enter the CIR rate for each egress priority queue in the text boxes Click the Cancel button to revert back to the previous Apply...

Page 135: ...ass 0 1 2 3 4 5 6 7 Egress Queue vs Frame Priority Default Mapping Class of Service profiles can use DSCP or PCP fields to reclassify and prioritize the ingress frames Differentiated Services Code Poi...

Page 136: ...over layer 2 when both are present On an access port only untagged frames are accepted with the following format Data On a tunnel port zero or one tag is allowed for DSCP selection with the following...

Page 137: ...or Port P4 Select Global Link Redundancy Configuration Link Redundancy is only supported on modules with 2 fiber ports Use the Link Redundancy Configuration pull down menu to select No Redundant fiber...

Page 138: ...e lowest priority is elected as the Root Bridge for the domain The Bridge Priority can be modified in increments of 4096 from 0 to 61 440 The default Bridge Priority is 32 768 Enter a new value in the...

Page 139: ...u to select how BPDUs frames are handled Discard Peer or Tunnel Discard RSTP protocol is disabled on the module Peer RSTP protocol is enabled and RSTP BPDUs frames are processed Tunnel RSTPprotocol is...

Page 140: ...0 being the highest priority is a valid entry The default Port Priority is 128 Enter a new value in the text box RSTP Path Cost The cost of a port is typically based on port speed The faster the port...

Page 141: ...ecessary to bill for services Remote Authentication Dial In User Service RADIUS is a client server system that secures networks against unauthorized access When a user tries to access a specific modul...

Page 142: ...ethods can be configured Click the Cancel button to revert back to the previous Apply state Click on the Apply button to activate the changes Click the Save button to permanently save the changes Use...

Page 143: ...the text box The default value is 60 seconds Click the Cancel button to revert back to the previous Apply state Click on the Apply button to activate the changes Click the Save button to permanently s...

Page 144: ...Server Timeout s Enter the server timeout value in seconds in the text box The default value is 60 seconds Number of Server Retries Enter a value in seconds between 0 and 10 in the text box The defaul...

Page 145: ...ac Bypass On or Off Automatic Standard 802 1X authentication on a port Mac Bypass 802 1X MAC bypass authentication on a port On Port is always authorized 802 1X disabled Off Port is always unauthorize...

Page 146: ...ecified the ACL is added to the list but is not properly applied Changing the protocol to TCP or adding the IP addresses individually will properly add the ACL to the list If an error is returned when...

Page 147: ...ct the access type as Permit or Deny Destination Port When TCP or UDP is selected under Protocol enter the destination port number in the text box Click the Delete button to delete all ACL entries Cli...

Page 148: ...ncryption key Select DSA Key Only RSA Key Only or DSA RSA Key DSA RSA Key is the default RSA Public key generated via the Rivest Shamir and Adleman algorithm DSA Public key generated via the Digital S...

Page 149: ...to log into the Serial web Telnet FTP and SSH interfaces User Username Displays the user name Password Displays associated with the password User Type Displays the type of user Session Timeout s Disp...

Page 150: ...Session Lockout s Displays the value in seconds for the session lockout FTP Session Timeout s Displays the value in seconds of the FTP session timeout Click the Modify button to change the User parame...

Page 151: ...A Z 0 9 and the special characters and space When changing the session timeout value using the Session Timeout s text box the new value will not take effect until the user logs out and logs back in U...

Page 152: ...out Use the Authentication Timeout text box to configure the authentication timeout in seconds A value of 0 to 300 seconds is a valid entry Session Lockout s Enter a new value for the session lockout...

Page 153: ...installed on the module and the current update status Current firmware revision Displays the current firmware Upgrade Firmware To upgrade the firmware or bootloader click the Browse button A file sele...

Page 154: ...o the latest version repeat the upgrade procedure as indicated above Current image version The details of the current firmware is displayed Next swap image version The details of the backup firmware i...

Page 155: ...le to factory defaults but retain the current IPsettings click the Restore Factory Default Retaining IP button A dialog box is displayed Click Yes or No to continue with defaulting the module to facto...

Page 156: ...Settings The Browser Settings screen provides the ability to change the auto refresh session timeouts and menu display options Auto Refresh Rate To change the Auto Refresh Rate use the pull down menu...

Page 157: ...the method of accessing the side menu Always Expanded Auto Expand or Click to Expand Always Expanded When selected all side menu options are displayed Auto Expand When selected the menu option will e...

Page 158: ...guration Syslog Protocol Use the Syslog Protocol pull down menu to select enable or disable syslog functionality Syslog Server IP Enter the IP address of the syslog service in the text box Severity Lo...

Page 159: ...Log Entries Severity Entries The number of the different entries are displayed Click the Cancel button to revert back to the previous Apply state Click on the Apply button to activate the changes Cli...

Page 160: ...ex number is assigned to each trap entry Date Time Displays the date and time of the trap entry Trap Displays the identifying number for the trap NOTE Selecting the SNMP Trap Filtering option for the...

Page 161: ...aps that can be generated by the module Each individual trap can be enabled or disabled and a severity level can be assigned Trap Identifies the trap by number Description Provides a short description...

Page 162: ...1 7 6 Splash Screen The Splash screen provides the ability to configure a message that is displayed after the module has been restarted or rebooted The message is displayed after the Entry screen is...

Page 163: ...he Input Data text box The message is visible in the Review Data text box Click the Cancel button to revert back to the previous Apply state Click on the Apply button to activate the changes Click the...

Page 164: ...45 Cable Types Copper Fiber Serial EIA TIA 568A B Cat 5 UTP and higher Multimode 50 125 62 5 125 m Single mode 9 125 m Category 3 and higher DC Power Requirements 4 RJ 45 Ports 46 to 57VDC 2 7A 48VDC...

Page 165: ...of the files may need to be renamed to the DOS 8 3 Format Rename the vx_x_xx_PoE_Prod dat to PoE dat and store the files in the root or c directory Renaming the file will allow the new file to overwr...

Page 166: ...directory is rwdata swctl updates ftp put location and filename of the application firmware enter firmware filename 200 OK 200 PORT command successful 150 Connecting to port 64533 226 File successful...

Page 167: ...erface The IP based web management can be accessed through any of the Ethernet RJ 45 or fiber ports and facilitates the configuration and real time operation monitoring of each port The factory defaul...

Page 168: ...d button to start the upgrade process NOTE Do not remove power during the upgrade procedure until the module has rebooted with the new firmware After the firmware has been upgraded it may be desirable...

Page 169: ...been upgraded by accessing the Firmware Upgrade screen The Current firmware revision will indicate the upgraded version If the firmware was upgraded a second time the Next swap image revision will al...

Page 170: ...oduct malfunctions resulting from improper or inadequate use and or maintenance of the equipment by Buyer Buyer supplied equipment Buyer supplied interfacing unauthorized modifications or tampering wi...

Page 171: ...roblems while installing this product contact Omnitron Technical Support Phone 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 38 Tesla Irvine CA 92618 USA Email support omnitron...