iConverter
3-Port GM3 Network Interface Device
Quick Start Guide
PRODUCT OVERVIEW
This document describes the basic installation and configuration of the 3-Port GM3 standalone
modules.
The GM3 features a RS-232 Serial Console Port and UTP and/or SFP ports. The SFP
ports support SERDES 100/1000BASE-X SFP fiber and Omnitron approved SGMII
10/100/1000BASE-T copper transceivers.
NOTE: When using third party 100BASE-FX and unapproved SGMII SFPs, the port must
be manually configured using the Connectivity Fault Management (CFM) Command Line
Interface (CLI). Interface settings can be changed using the
portattribute
command. For
more information including the complete User Manual on the 3-Port GM3 modules, access
Omnitron’s registration page and register the product:
http://www.omnitron-systems.com/forms/product_registration.php
INSTALLATION PROCEDURE
1) Configure DIP-Switches
2) Install Standalone Module and Connect Cables
3) Configure Module via Command Line Interface
4) Verify Operation
1) CONFIGURE DIP-Switches
DIP-SWITCH BANK 1
The function of DIP-switch Bank 1 is outlined in Figure 1 below.
Switch Position
Legend
Down (Default)
Up
1
P1 AN/MAN
AN
MAN
2
P2 AN/MAN
AN
MAN
3
P3 AN/MAN
AN
MAN
4
Port Redundancy (See Figure 2)
5
6
Link Modes (See Figure 3)
7
8
Figure 1: DIP-switch Bank 1
The location of the DIP-switch is illustrated in Figure 2 on the next page.
SW1 - SW3: P1, P2 and P3 AUTO/MANUAL NEGOTIATION “AN/MAN”
When these DIP-switches are in the Down “AN” position (factory default), the corresponding
port automatically determines the duplex and pause modes of the connected device. If the
connecting device cannot provide the proper signal to indicate its own mode of operation,
Port to the COM port of a computer equipped with terminal emulation software such as
HyperTerminal. The Console Port (DCE) is a mini DIN-6 female connector which can be
changed to a DB-9 connector with the included adapter. The GM3 Console Port is a standard
RS-232 asynchronous serial interface.
Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:”
window. Set the serial port to the following:
Bits Per Second
57,600
Stop Bits
1
Data Bits
8
Parity
NONE
Hardware Flow Control
NONE
Once connected, press <ENTER> to bring up a command line prompt on the attached PC.
A new GM3 module does not have a password, and will skip the Password Entry screen and
go straight to the Management Options screen. If a password has been set, the Password
Entry screen will be displayed. Type the password and press <ENTER>, the GM3 will respond
with the Management Options screen:
The CLI interface enables detailed configuration of the module.
4) VERIFY OPERATION
Once the module has been installed and configured per steps 1 - 3, verify the module is
operational by viewing the LED indicators.
LED Function
“Legend”
Color
OFF State
ON/Blinking State
Power
“PWR”
Green
No power
ON: Module has power
P1 Link Activity
“100”
Green
Port not linked at 100M
ON: Port linked at 100M
Blinking: Data activity
P1 Link Activity
“1000”
Green
Port not linked at 1000M
ON: Port linked at 1000M
Blinking: Data activity
P1 Link Activity
“100” and “1000”
Green
Port not linked at 10M
ON: Port linked at 10M
Blinking: Data activity
P2 Link Activity
“100”
Green
Port not linked at 100M
ON: Port linked at 100M
Blinking: Data activity
P2 Link Activity
“1000”
Green
Port not linked at 1000M
ON: Port linked at 1000M
Blinking: Data activity
P2 Link Activity
“100” and “1000”
Green
Port not linked at 10M
ON: Port linked at 10M
Blinking: Data activity
Test/Alarm
“Tst/Alm”
Green
Reserved
Reserved
Management Mode
“Msr/Slv”
Green
N/A
ON: Master (normal)
5 Hz Blinking: Secure Slave
P3 Link Activity
“100”
Green
Port not linked at 100M
ON: Port linked at 100M
Blinking: Data activity
P3 Link Activity
“1000”
Green
Port not linked at 1000M
ON: Port linked at 1000M
Blinking: Data activity
P3 Link Activity
“100” and “1000”
Green
Port not linked at 10M
ON: Port linked at 10M
Blinking: Data activity
Figure 4: LED Indicators
040-8970P-001C 8/11
Page 1
Omnitron Systems Technology * 140 Technology Dr., #500 * Irvine, CA 92618