background image

1

 RYAN

  OMNIPOD

®

 WEARER

Caregiver Guide

WITH THE OMNIPOD

®

 

SYSTEM

Summary of Contents for PDM CAT45E

Page 1: ...1 RYAN OMNIPOD WEARER Caregiver Guide WITH THE OMNIPOD SYSTEM...

Page 2: ...s Diabetes Management Plan input from their caregivers and or healthcare provider and the OmniPod Insulin Management System User Guide PDM imagery is for illustrative purposes only and should not be...

Page 3: ...hat the OmniPod is trusted by tens of thousands of wearers worldwide along with caregivers like you And you can count on us to be there for you whenever you need us with 24 7 comprehensive customer su...

Page 4: ...2 The Pod TOP Viewing Window BOTTOM Adhesive Backing Needle Cap Fill port A small lightweight Pod that s easy to apply and wear...

Page 5: ...nsulin delivery for exercise or illness according to the individual s Diabetes Management Plan This menu item is present only if the Temp basal option is turned on My records Review insulin delivery b...

Page 6: ...ause an individual s food intake may be unpredictable consult the individual s Diabetes Management Plan or healthcare provider to determine the appropriate timing of insulin delivery Check the individ...

Page 7: ...w Cancel Yes No 3 00p 2 11 When blood glucose reading appears press Next to continue If eating now press Yes OR If not eating press No Wash the finger with soap and water or an alcohol wipe and dry it...

Page 8: ...troller button to enter the correct number of carbs then press Enter How to check blood glucose and deliver a bolus Suggested bolus 5 00U Carbs 60g BG 150mg dL Back Enter 5 00U 3 00p 2 11 Extend Sugge...

Page 9: ...not part of the individual s Diabetes Management Plan the Extend option will not appear on the screen 8 Start bolus Now Ext 0 0 hr Total Back Confirm 5 00U 0 00U 5 00U 3 00p 2 11 Cancel Delivering bo...

Page 10: ...eservoir is low or empty or the Pod is nearing expiration In response to an alarm If the Pod has become dislodged If the individual has a blood glucose reading of 13 9 mmol L or more and has moderate...

Page 11: ...dhesive Use soap and water to remove any adhesive that remains on the skin or if necessary use an adhesive remover Press Yes to activate a new Pod Follow the steps on pages 11 and 12 to fill a new Pod...

Page 12: ...Arm and Leg Position the Pod vertically or at a slight angle Back Abdomen and Buttocks Position the Pod horizontally or at a slight angle SITE SELECTION Change the site location each time you apply a...

Page 13: ...packaging Use the alcohol prep swab to clean the top of the insulin vial Assemble the fill syringe by twisting the needle onto the syringe Remove the protective cap If the PDM screen times out during...

Page 14: ...he Pod back in the original packaging tray and put it to the right of and touching the PDM Insert the needle straight down into the fill port on the underside of the Pod To ensure proper fill do not i...

Page 15: ...PDM If the PDM screen times out press and hold the Home power button to turn it back on Press Next The PDM establishes a one to one relationship with the Pod which will not allow it to communicate wi...

Page 16: ...n If you are unsure whether to use a specific site ask the individual s healthcare provider Run your finger around the adhesive to secure it Press Next on the PDM To facilitate insertion place one han...

Page 17: ...else into the fill port while the Pod is on the individual s body Doing so may result in unintended or interrupted insulin delivery If you observe blood in the cannula check the individual s blood gl...

Page 18: ...l rate prior to increased physical activity physical education or organized sports or in response to low blood sugar that does not respond to oral carbohydrates or other efforts The individual s Diabe...

Page 19: ...ains Home Pod exp 6 28a 2 14 50 U Enter the length of time the temp basal should be delivered in half hour increments then press Enter Press Confirm to start the temporary basal rate shown on the scre...

Page 20: ...s or lead to unconsciousness Symptoms of hypoglycemia Never ignore these symptoms Status Select 3 00p 2 11 Bolus More actions Temp basal My records Settings Suspend Suspend insulin delivery Enter dura...

Page 21: ...ard candy End of insulin suspend Press OK to resume basal rate delivery OK 3 00p 2 11 The Pod will beep every 15 minutes until the end of the suspension period At the end of the suspension period a Po...

Page 22: ...insulin to inject if delivery from the Pod is interrupted Blood glucose test strips Ketone test strips Lancing device and lancets Glucose tablets or another fast acting source of carbohydrate Alcohol...

Page 23: ...heir healthcare provider 3 TEMP BASAL SETTINGS Select Settings System setup Bolus basal calcs Temp basal Check the box below that matches the Temp basal setting U hr Off 1 MAX BASAL Select Settings Sy...

Page 24: ...factors targets Target BG Write down the settings for Target correct above 12 00a Segment Target correct above mmol L mmol L 6 BOLUS CALCS Select Settings System setup Bolus basal calcs Bolus calcs Ch...

Page 25: ...Ratios factors targets Reverse correction Check the box below that matches the Reverse correction setting On Off 12 INSULIN ACTION Select Settings System setup Bolus basal calcs Ratios factors target...

Page 26: ...sal calcs Extended Check the box below that matches the Extended setting Units Off 14 MAX BOLUS Select Settings System setup Bolus basal calcs Max bolus Write down the value for Max bolus setting U 16...

Page 27: ...25 NOTES I can feel confident knowing we re taking better care of my son s health for the long term with the OmniPod And I know he feels better about himself NANCY mother of 12 year old Ryan...

Page 28: ...ording to instructions Do not use the integrated FreeStyle Blood Glucose Monitoring System for Testing on newborns Testing arterial blood Diagnosing of or screening for diabetes mellitus Warnings The...

Reviews: