Preface

1 Preface

The purpose of this manual is to familiarize users with the 

CMC 850

 test set and to show how to 

properly use it in various application areas. The manual contains important tips on how to use 

CMC 850

 safely, properly, and efficiently. Its purpose is to help you avoid danger, repair costs, and 

down time as well as to help maintain the reliability and life of 

CMC 850

.

This manual is to be supplemented by existing national safety standards for accident prevention and 
environmental protection. Keep it available at the site where 

CMC 850

 is used. It should be read by all 

personnel operating the test set. In addition to the manual and the applicable safety regulations in the 
country and at the site of operation, heed the usual technical procedures for safe and competent work.

This manual describes the 

CMC 850

 hardware - that is, the physical test set. In order to get 

familiar with the software for controlling and configuring 

CMC 850

, please refer to the  

Test Universe

RelaySimTest

 and/or the Web Interface Help and their accompanying software 

manuals.

2 Safety Instructions

Before operating the 

CMC 850

 test set, carefully read the following safety instructions. Only operate 

(or even turn on) 

CMC 850

 after you have read this manual and fully understood the instructions 

herein.

CMC 850

 may only be operated by trained personnel. Any maloperation can result in damage to 

property or persons.

2.1 Rules for Use

CMC 850

 should only be used when in a technically sound condition. Its use should be in 

accordance with the safety regulations for the specific job site and application. Always be aware of 
the dangers of the high voltages and currents associated with this equipment. Pay attention to the 
information provided in the manual and the software documentation.

CMC 850

 is exclusively intended for the application areas specified in section 3 "Designated Use". 

The manufacturer/distributors are not liable for damage resulting from unintended usage. The user 
alone assumes all responsibility and risk.

• The instructions provided in this manual and the associated software manuals are considered part 

of the rules governing proper usage.

• Do not open 

CMC 850

 or remove any of its housing components.

2.2 Orderly Practices and Procedures

• Keep this manual available on site where 

CMC 850

 is used, either in electronic form as PDF or 

printed-out.

• Personnel assigned to using 

CMC 850

 must have read this manual and fully understood the 

instructions herein.

• Do not carry out any modifications, extensions or adaptations at 

CMC 850

.

Summary of Contents for CMC 850

Page 1: ...CMC 850 User Manual...

Page 2: ...is not permitted The product information specifications and technical data embodied in this manual represent the technical status at the time of writing Subject to change without notice OMICRON elect...

Page 3: ...esignated Use 8 4 Functionality 8 4 1 Interfaces to the Test Environment 8 4 2 Operating CMC 850 with a controlling test software 8 4 3 Time Synchronization 9 4 4 Web Interface 9 5 Connections and Int...

Page 4: ...w Level Outputs LL out 1 6 and LL out 7 12 18 7 3 Low Level Binary Outputs ext Interf 19 7 4 Technical Data of the Communication Ports 20 7 4 1 The NET 2 Board 20 7 4 2 The NET 1C Board 21 7 4 3 The N...

Page 5: ...instructions Only operate or even turn on CMC 850 after you have read this manual and fully understood the instructions herein CMC 850 may only be operated by trained personnel Any maloperation can re...

Page 6: ...eed free and quick access Before connecting and disconnecting test objects verify that all outputs have been turned off Never connect or disconnect a test object while the outputs are active When disc...

Page 7: ...a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes or modifications not expressly approved by the...

Page 8: ...ontrolling test software Test Universe As long as the interaction with devices under test utilizes GOOSE and Sampled Values the CMC 850 test set supports all test modules of the Test Universe software...

Page 9: ...ting with CMC test sets and the Test Universe software It serves as the clearing house for IRIG B and PPS signals regardless whether they come from an external clock or from the CMC itself CMIRIG B fa...

Page 10: ...s enables direct remote control of CMC 850 e g for end to end testing The Ethernet ports also provide the basis for the processing of substation protocols according to the IEC 61850 standard They allo...

Page 11: ...he network This may lead to dangerous situations where a user accidentally connects to a device located on a desk of somebody else emitting unsafe voltages and endangering the person working there To...

Page 12: ...aiting for an emergency software image download This is the case when pressing the button while powering up the CMC test set B green LED If the yellow LED A is off the green LED B signals the followin...

Page 13: ...n Protocol and AutoIP APIPA Automatic Private IP Addressing If the IP settings conflict with IP settings of other devices in the network it is possible to reset the test set to factory defaults DHCP a...

Page 14: ...e the OMICRON supplied CMIRIG B interface unit as reference for the a time synchronization of the IEC 61850 bus system connect the CMIRIG B s front side connector CMC to the CMC 850 s external Interfa...

Page 15: ...cal data Low Level Outputs LL out 1 6 and LL out 7 12 on page 18 Overload Warning in the Test Software When a low level output is overloaded the test software issues an appropriate warning Refer to th...

Page 16: ...1 Install the test software on your computer The test software can either be the Test Universe or the RelaySimTest software Both software packages also install the OMICRON Device Link Use OMICRON Devi...

Page 17: ...ccessible via its Web Interface Any common Web browser can be used to access CMC 850 and to make use of the embedded functions Alternative method to invoking the Web browser by the procedures describe...

Page 18: ...connector Standard DC barrel jack 2 1 mm x 5 5 mm x 11 mm center pin is positive Output voltage 10 V 10 V Max output current 1 mA Accuracy Typical error 0 025 guaranteed 0 07 at 1 V 10 V Resolution 2...

Page 19: ...pull up resistor Switching voltage Max 15 V Max input voltage 16 V Switch current Max 5 mA current limited min 100 A Actualization time 100 s Rise time 3 s Vextern 5 V Rpullup 4 7 k Insulation Reinfor...

Page 20: ...Mbit s USB 1 1 compatible USB connector USB type B connect to computer USB cable USB 2 0 high speed type A B 2 m 6 ft ETH type 10 100 1000Base TX1 twisted pair auto MDI MDIX or auto crossover 1 10Bas...

Page 21: ...ablished port active green LED ON Traffic via ETH port yellow LED is blinking ETH Power over Ethernet PoE IEEE 802 3af compliant Port capability limited to one Class 1 3 84 W and one Class 2 6 49 W po...

Page 22: ...ransformers Using IEC 61850 9 2LE of the UCA International Users Group and to the IEC 61869 9 2016 Instrument transformers Part 9 Digital interface for instrument transformers with fixed DataSets Samp...

Page 23: ...E 37 238 2011 Power Profile IEC PAS 61850 9 3 Communication Networks and Systems for Power Utility Automation Part 9 3 Precision Time Protocol Profile for Power Utility Automation Utility Profile Typi...

Page 24: ...EU and the low voltage Directive 2014 35 EU Electromagnetic Compatibility EMC Emission Europe International USA EN 61326 1 EN 61000 6 4 EN 61000 3 2 3 IEC 61326 1 IEC 61000 6 4 IEC 61000 3 2 3 FCC Sub...

Page 25: ...ICRON Open Source Download Area at www omicronenergy com opensource Open this address in your Internet browser click the Download Software button and navigate to the CMC Embedded Image directory Look...

Page 26: ...26 CMC 850 User Manual...

Page 27: ...a 43 59495 4444 Additionally you can find our Service Center or Sales Partner closest to you at www omicronenergy com Customer Portal Stay Informed www omicronenergy com customer The Customer Portal o...

Page 28: ...OSE technical data 22 GPS time synchronization 8 I IP address of CMC 850 17 IP configuration 13 IP parameters 13 IRIG B time synchronization 8 L LED A B Status LED 12 LL out low level outputs 15 techn...

Page 29: ...tware 8 communication with CMC 850 13 time synchronization technical data 23 time synchronization with IRIG B 14 U USB Port 11 USB port on NET 1C board technical data 20 21 on NET 2 board technical da...

Page 30: ...CMC 850 User Manual 30...

Page 31: ...ENU 1015 05 03...

Reviews: