Increasing the Output Power, Operating Modes
95
7.2.4 Single-Phase
Voltage
1 x 0 ... 300 V, 1 x 200 VA [100 ... 300 V] typical
Figure 7-4:
Single-phase operation of
the voltage system (L-N)
1 x 0 ... 600 V, 1 x 275 VA [200 ... 600 V] typical
Figure 7-5:
Single-phase operation of
the voltage system
(L-L phase opposition)
Refer to the output curves shown in the figures 6-8 through 6-9 in section
6.3.3, "Voltage Outputs" on page 48.
Note:
Never connect N’ or any other phase to GND (PE). This can cause
life-hazardous
situations to persons and damage to property.
Load
1’
N’
Load
1’
N’