Digital Input / Output Descriptor 

The DIO Interface provides 2 digital inputs which are hardwired to the digital outputs. These may be used to detect the 

state of external switches (output off) or to monitor the state of the outputs. The DIO Input descriptor is at base addresses 

0x0068.

 

 

Offset

 

Name 

Value 

Description 

0x00 

Sensor Type 

0x18 

Digital Type (Bit mapped) 

0x01 

Data Type/Format 

0x46 

Configurable, Float type 

0x02 

Configuration 

0x23 

Scaling applied, Bits 0 and 1 enabled 

0x03 

Sensor Device 

0x0f 

DIN bits enabled / inverted 

0x04..0x08 

UOMR 

“DIN” 

Units of measure 

5.2.1

 

DIO Sensor Type 

The interface provides a bit mapped input of the 2 digital signal lines. 

 

Sensor Type

 

SI Derived Units 

Measurement 

0x18 

DIN 

Bit mapped digital inputs 

5.2.2

 

DIO Data Type/Format 

 

DIO Data Type 

7

 

Smart Sensor 

Sensor 

Writable 

Factory 

Calibrate 

reserved 

Data Type 

6 == Floating point 

 

Note: 

Please refer to the Smart Sensor Interface Technical Guide for more information regarding this descriptor.

 

5.2.2.1

 

Data Type 

The 4-bit Data Type field determines the type of date of the specific sensor. 

5.2.2.2

 

Factory Calibrate 

The Factory Calibrate bit is not used for DIO types. 

5.2.2.3

 

Sensor Writeable 

If the Sensor Writeable bit is set the sensor value may be overwritten with a preset value.  

5.2.2.4

 

Smart Sensor 

Refer to the 

Smart Sensor Device Interface

 documentation. 

5.2.3

 

DIO Input Configuration 

 

DIO Input Configuration 

Available  Assigned 

 

Apply 

Scaling 

Lock 

Sub Channel Selection 

0x03 == bits 0 and 1 

 

5.2.3.1

 

Lock 

If set, the user specified units of measure string (4-character maximum) will be used in place of the default 

DIN. 

 

 

Summary of Contents for SP-014

Page 1: ...1 P a g e TM User sGuide Shop online at omega com e mail info omega com For latest product manuals www omegamanual info SP 014 Process Monitoring Smart Probe...

Page 2: ...nly Customer Service 1 800 622 2378 USA Canada only Engineering Service 1 800 872 9436 USA Canada only U S A Headquarters Tel 203 359 1660 e mail info omega com Fax 203 359 7700 The information contai...

Page 3: ...5 1 2 4 Smart Sensor 12 5 1 3 Process Input Configuration 12 5 1 3 1 Sensor Type Range 12 5 1 3 2 Apply Scaling 12 5 1 3 3 Lock 12 5 1 3 4 Assigned 12 5 1 3 5 Available 12 5 1 4 Process Input Sensor D...

Page 4: ...4 P a g e 5 3 2 Active State 17 5 3 3 Output Drive 17 5 3 4 Output Type 17 6 Specifications 18 7 Errata 18...

Page 5: ...vice as it contains important information relating to safety and EMC Failure to follow all the safety precautions may result in injury and or damage to your equipment The following labels identify inf...

Page 6: ...onfigured as 0 24 mA or 0 1 0 VDC inputs The Layer N SP 014 features 2 configurable digital I O pins These can be used for a myriad of applications including driving relays physical alarms or sensing...

Page 7: ...process inputs through its M12 5 Pin connector If you are connecting wires directly to the SP 014 view the wiring diagrams provided below Pin Name Function Pin 1 DIO 0 Discrete I O Signal 0 Pin 2 INT...

Page 8: ...ly detect your device follow these instructions to manually connect it Step 1 Click on the icon located on the top left of the SYNC interface Step 2 Proceed through the Add Device Wizard and click End...

Page 9: ...rols bits per second DataBits The number of bits in each character sent Parity A means of checking correctness of character by adding an extra bit to the character and setting the value based on all t...

Page 10: ...Action section The alarm can be set to be latching or non latching in the Recovery section 4 5 ON OFF Control To configure ON OFF Control on a device navigate to the Output Configuration Tab in SYNC...

Page 11: ...extended measurement type precision and tracking of minimum maximum readings Each enumerated Sensor has a Descriptor Base address location and a Sensor IPSO Configuration structure address location b...

Page 12: ...Writeable The writable bit is cleared indicating that the sensor values may not be overwritten 5 1 2 4 Smart Sensor Refer to the Smart Sensor Device Interface documentation 5 1 3 Process Input Config...

Page 13: ...0 0x04 Sensor Trigger Write any value to force reset of min max 0x08 Min Measured Minimum reading since last reset 0x0c Max Measured Maximum reading since last reset 0x10 Min Range Range Minimum Maxi...

Page 14: ...ed digital inputs 5 2 2 DIO Data Type Format DIO Data Type 7 6 5 4 3 2 1 0 Smart Sensor Sensor Writable Factory Calibrate reserved Data Type 0 0 0 0 6 Floating point Note Please refer to the Smart Sen...

Page 15: ...ert Bit is set the signal will be Active Low DIO Device Configuration 7 6 5 4 3 2 1 0 Reserved DIN 1 DIN 0 0 0 0 0 ENABLE INVERT ENABLE INVERT 1 1 1 1 5 2 4 1 Invert If the Invert bit is set the input...

Page 16: ...uts and all bits should be written as 0 5 2 6 DIO Input Circuitry The DIO input circuitry shares the output circuitry The internal processor drives the Output Control signal to turn on the output driv...

Page 17: ...10 Hz PWM signal has constant 10 Hertz frequency 100 msec repetition rate with 0 100 duty cycle 2 1 Hz PWM signal has constant 1 Hertz frequency 1 second repetition rate with 0 100 duty cycle 3 0 1 H...

Page 18: ...ature 0 02 FS C ENVIRONMENTAL Operating Temperature 40 to 85 C 40 to 185 F Rating IP67 when mated MECHANICAL Dimensions 22 1 mm W x 96 7 mm L 0 87 x 3 80 not including mounting tabs GENERAL Agency App...

Page 19: ...A if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to m...

Page 20: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...

Reviews: