OS1592

Infrared Fiber Optic

Thermometer/Transmitter

MADE IN

omega.com  

e-mail: [email protected]

For latest product manuals:

omegamanual.info

Shop online at

User’s Guide

Summary of Contents for OS1592

Page 1: ...OS1592 Infrared Fiber Optic Thermometer Transmitter MADE IN omega com e mail info omega com For latest product manuals omegamanual info Shop online at User sGuide ...

Page 2: ...nce TEL 33 0 1 61 37 2900 FAX 33 0 1 30 57 5427 Toll Free in France 0800 466 342 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de United Kingdom One Omega Drive River Bend Technology Centre ISO 9002 Certified Northbank Irlam Manchester M44 5BD United Kingdom TEL 44...

Page 3: ...otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans...

Page 4: ...3 Operation 4 3 1 Changing the Temperature from F or C or vice versa 5 3 2 Turning on the Display Backlight 5 3 3 Using the Alarm Function 5 3 4 Analog Output vs Temperature 5 3 5 Resetting Temperature Values 6 Section 4 Specifications 9 Section 5 Maintenance 11 OS1592 Infrared Fiber Optic Thermometer Transmitter Table of Contents i ...

Page 5: ...e 6 5 Optical Lens Assembly L1 25 8 FOV 7 6 Optical Lens Assembly L1 19 20 FOV 7 7 Optical Lens Assembly L1 076 6 FOV 7 8 Ceramic Tip Assembly L2 7 9 Polymer Bolt Assembly L3 with 90 Angle Air Purge Fitting 8 10 Optical Head Mounting Bracket OS1592 MB 8 11 Air Purge Collar OS1592 AP 8 OS1592 Infrared Fiber Optic Thermometer Transmitter Table of Figures ii ...

Page 6: ...INSTALLATION 2 1 Unpacking Remove the packing list and verify that you have received all your equipment If you have any questions about the shipment please call Customer Service at 1 800 622 2378 or 203 359 1660 We can also be reached on the internet www omega com e mail info omega com When you receive the shipment inspect the container and equipment for any signs of damage Note any evidence of ro...

Page 7: ...60 538 C 500 to 1000 F Polymer Bolt 10 2 cm 4 Probe 1 52 m 5 OS1592 L1 R2 1 538 1093 C 1000 to 2000 F Lens Probe 6 3 mm 0 25 20 3 cm 8 1 52 m 5 OS1592 L1 R2 2 538 1093 C 1000 to 2000 F Lens Probe 4 8 mm 0 19 50 8 cm 20 1 52 m 5 OS1592 L1 R2 3 538 1093 C 1000 to 2000 F Lens Probe 1 9 mm 0 076 15 2 cm 6 1 52 m 5 OS1592 L2 R2 538 1093 C 1000 to 2000 F Ceramic Tip 15 2 cm 6 Probe 1 52 m 5 OS1592 L3 R2...

Page 8: ...ect the fiber optic assembly from the main electronic unit and connect to the light source The focused light through the fiber optic assembly provides the positioning of the optical assembly on the target After the positioning reconnect the fiber optic assembly back to the main unit Figure 1 OS1592 Main Unit Figure 2 Power Supply and Analog Output Connections OS1592 Infrared Fiber Optic Thermomete...

Page 9: ... MODE Press to Go to Go to Go to Go to Go to Press to Press or to Display shows Current temperature Emissivity Set emissivity Press to change between F C Press to turn LCD backlighting ON and OFF Activate Deactivate Reset Max Min Dif temperatures Set High alarm value __ __ __ Current temperature High alarm setpoint Current temperature Maximum temperature Current temperature Minimum temperature Cur...

Page 10: ... value 3 Press the key to enable the high alarm function The icon appears on the display If the temperature exceeds the high alarm set point the unit goes into an alarm condition The icon on the display flashes the alarm red LED turns on and the internal relay energizes The relay contacts are brought out to the terminal block J101 for ease of access 4 To disable the high alarm function press the k...

Page 11: ...ed temperatures as follows MAX Current Temperature MIN Current Temperature DIF 0 After the reset the unit starts to keep track of the Maximum Minimum and Differential temperatures The following figures show the Main Housing Optical Assemblies Mounting Bracket and Air purge Collar Figure 4 NEMA 4 Aluminum Enclosure OS1592 Infrared Fiber Optic Thermometer Transmitter 3 6 77 90 3 067 71 93 2 832 89 9...

Page 12: ...mic Tip Assembly L2 OS1592 Infrared Fiber Optic Thermometer Transmitter 3 7 111 4 38 159 6 25 Dimensions mm in FIBER 19 75 DIA 25 4 1 00 DIA 111 4 38 149 5 87 19 75 DIA FIBER 25 4 1 00 DIA Dimensions mm in 183 7 22 264 10 38 FIBER 19 75 DIA 25 4 1 00 DIA Dimensions mm in 12 7 50 152 6 00 46 1 812 6 35 250 DIA FIBER 4 8 190 DIA Dimensions mm in ...

Page 13: ...8 0 307 7 7 0 305 11 0 414 10 0 412 5 3 0 209 5 6 0 219 45 15 7 0 62 ACROSS FLATS 1 2 20 UNF 2A 12 7 0 50 6 35 0 25 AIR PURGE FITTING Dimensions mm in Dimensions mm in 24 6 0 97 44 5 0 75 30 R 17 0 0 67 6 35 0 25 3 3 0 13 7 62 0 30 25 4 1 00 44 5 1 75 17 5 0 69 4 8 0 19 19 0 75 44 5 1 75 44 5 1 75 6 35 0 25 15 7 0 62 35 1 38 o 25 4 1 00 o 156 TOP LIP 6 32 UNC 12 7 1 2 DEEP FROM 3 3 0 13 SLOT Dimen...

Page 14: ... S 1 9 mm 152 mm 0 076 6 79 1 Fiber Bundle 1 8 mm 0 070 Dimensions 25 4 mm 1 OD x 264 mm 10 38 L 3 Lens Probe L1 2 Spot Size D S 4 8 mm 508 mm 0 19 20 105 1 Fiber Bundle 0 5 mm 0 020 Dimensions 25 4 mm 1 OD x 149 mm 5 87 L 4 Ceramic Tip L2 152 4 mm 6 Probe Fiber Bundle 1 8 mm 0 070 Dimensions 48 mm 0 190 OD x 152 4 mm 6 L 5 Polymer Bolt L3 101 6 mm 4 Probe with air purge fitting Fiber Bundle 1 8 m...

Page 15: ...cale Max Load 350 Ohms 3 0 5 VDC Optional V1 Accuracy 0 25 of Full Scale Min Load 250 Ohms 4 0 10 VDC Optional V2 Accuracy 0 25 of Full Scale Min Load 750 Ohms 5 J type Thermocouple Optional J 500 to 1000 F Range R1 Accuracy 7 F Cold Junction compensated 6 K type Thermocouple Optional K 500 to 1000 F Range R1 1000 to 2000 F range R2 Accuracy 7 F Cold Junction compensated Air Purge Collar OS1592 AP...

Page 16: ... by use of an air jet or a soft brush Dirt films and other accumulations should be removed by the use of soft cotton or a Q tip moistened with Windex triple distilled alcohol or other grease free and solids free solvent A final wiping with dry cotton is recommended If the fiber bundles are to be removed from the detector head assemblies for extended periods the fiber bundle receptacles in the head...

Page 17: ... equipment may be impaired The installation category is one 1 There are no user replaceable fuses in this product The output terminals of this product are for use with equipment digital meters chart recorders etc which have no accessible live parts Such equipment should comply with all the applicable safety requirements Do not operate the equipment in flammable or explosive environments All connec...

Page 18: ...ors 䡺 Turbine Paddlewheel Systems 䡺 Totalizers Batch Controllers pH CONDUCTIVITY 䡺 pH Electrodes Testers Accessories 䡺 Benchtop Laboratory Meters 䡺 Controllers Calibrators Simulators Pumps 䡺 Industrial pH Conductivity Equipment DATA ACQUISITION 䡺 Data Acquisition Engineering Software 䡺 Communications Based Acquisition Systems 䡺 Plug in Cards for Apple IBM Compatibles 䡺 Datalogging Systems 䡺 Record...