background image

OS136A SERIES

Miniature Low-Cost  

Non-Contact Infrared  

Temperature Sensor/Transmitter

TM

e-mail: [email protected] 

For latest product manuals: 

www.omegamanual.info

Shop online at 

omega.com

User’s Guide

CAUTION! - This product

is not intended for medical

use or use on humans

!

CAUTION! - This product

is not intended for medical

use or use on humans

!

NORWALK, CT

Summary of Contents for OS136A Series

Page 1: ... Transmitter TM e mail info omega com For latest product manuals www omegamanual info Shop online at omega com User sGuide CAUTION This product is not intended for medical use or use on humans CAUTION This product is not intended for medical use or use on humans NORWALK CT ...

Page 2: ...specifications without notice omega com info omega com Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Canada only Engineering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide ...

Page 3: ...Symbols iii Section 1 Introduction 1 Section 2 Installation 1 2 1 Unpacking 1 2 2 Electrical Connection 2 Section 3 Operation 3 3 1 Measuring Temperature 3 3 2 Ambient Temperature 3 3 3 Atmospheric Quality 4 Section 4 Laser Sight Accessory 6 4 1 Warnings and Caution 6 4 2 Operating the Laser Sight Accessory 6 Section 5 Specifications 8 5 1 General 8 5 2 Laser Sight Accessory 9 ...

Page 4: ...re Description Page 2 1 General Wiring Diagram 2 3 1 Optical Field of View 3 3 2 Mounting Bracket OS100 MB 4 3 3 Air Purge Collar OS100 AP 4 3 4 Stainless Steel Housing 5 3 5 Water Air Cool Jacket OS136 WC 5 3 6 Water Air Cool Jacket Assembly 5 4 1 Laser Sighting Accessory OS100 LS 7 4 2 Laser Warning Label 7 ...

Page 5: ...ons The cable is a multi conductor 24 AWG stranded wire with the rating of 600 VDC 205ºC 401 F PTFE insulation Power must be disconnected before making any electrical connections The recommended power supply should be VDE or UL approved Rating 12 24 VDC 50 mA min power with overload protection The supply voltage to the transmitter should not exceed 24 VDC SAFETY WARNINGS AND IEC SYMBOLS This devic...

Page 6: ...A 4 rated The unit comes with a 1 82 m 6 shielded cable as standard SECTION 2 INSTALLATION 2 1 Unpacking Remove the packing list and verify that you have received all your equipment If you have any questions about the shipment please call the Customer Service at 1 800 622 2378 or 203 359 2208 We can also be reached on the internet at omega com email cservice omega com When you receive the shipment...

Page 7: ...wer and output connections Fig 2 1 shows the wiring diagram for different analog outputs Figure 2 1 General Wiring Diagram Accessories Model No Description OS100 MB Mounting Bracket OS136 WC Water Air Cooling Jacket OS100 AP Air Purge Collar OS100 LS Laser Sighting PSU 93 Unregulated 16 24 VDC Power Supply CAL 3 IR NIST Traceable Calibration Installation RED WHITE YELLOW THERMOCOUPLE METER RECORDE...

Page 8: ...ransmitter can operate in an ambient temperature of 0 to 70 C 32 to 158 F without any water cool jacket It can operate from 0 to 200 C 32 to 392 F with the water cool jacket accessory OS136 WC Fig 3 5 3 6 It can operate up to 110 C 230 F with air cooling There is a warm up period of 1 to 2 minutes after power up After the warm up period temperature measurement can be made When the ambient temperat...

Page 9: ... following figures show the Mounting Bracket OS136 MB Air Purge Collar OS136 AP Stainless Steel Housing Water Air Cool Jacket OS136 WC and the Water Air Cool Jacket Assembly Figure 3 2 Mounting Bracket OS100 MB Figure 3 3 Air Purge Collar OS100 AP 23 3 0 919 Ø 19 0 755 Ø 4 0 156 31 8 1 25 90ϒ 3 2 1 8 12 7 0 5 12 7 0 5 50 0 1 97 3 2 1 8 25 4 1 42 9 1 69 Dimensions mm in Dimensions mm in 28 6 1 125 ...

Page 10: ... HEX KNURL 4 76 3 16 WIDE DIMENSIONS mm in 3 4 16 UNF 88 9 3 5 1 83m 6ft 33 27 1 31 19 05 0 75 1 8 NPT COMPRESSION FITTING 2 PLCS 34 80 1 37 85 09 3 35 7 62 0 30 3 4 16 UNF 2B 3 4 16 UNF INLET OUTLET Dimensions mm in MOUNTING BRACKET OUTLET INTLET OS136A UP TO 200C 392F AMBIENT TEMPERATURE WITH WATER COOLING MOUNTING NUT Dimensions mm in ...

Page 11: ...ide 4 2 Operating the Laser Sight Accessory The Laser sight accessory screws onto the front of the transmitter sensor head This accessory is only used for alignment of the transmitter head to the target area After the alignment process the accessory has to be removed from the front of the transmitter head before temperature measurement is made The laser sight accessory is powered from a small comp...

Page 12: ...y OS100 LS Figure 4 2 Laser Warning Label Laser Sight Accessory 4 LASER WARNING LABEL DC POWER JACK LED LASER POWER INDICATOR LASER BEAM 19 0 75 50 8 2 0 38 1 1 5 POWER CABLE ON OFF SWITCH BATTERY PACK POWER SUPPLY OS136A Dimensions mm in ...

Page 13: ...ents Min Load 0 to 5 Vdc 1 K Ohms Min Load 0 to 10 Vdc 2 K Ohms Max Load 4 to 20 mA Power Supply 4 20 mA Min Load 10 mV Deg 10 K Ohms Min Load K T C 100 K Ohms Operating Ambient Temperature No Water Cooling 0 to 70ºC 32 to 158ºF With Water Cooling OS136 WC 0 to 200ºC 32 to 392ºF With Air Cooling OS136 WC 0 to 110 C 32 to 230 F Operating Relative Humidity Less than 95 RH non condensing Water Flow R...

Page 14: ...ser Beam Diameter Less than 5 mm Beam Divergence Less than 2 mrad Operating Temperature 0 to 50 C 32 to 122 F Operating Relative Humidity Less than 95 RH non condensing Power Switch ON OFF Slide switch on the Battery Pack Power Indicator Red LED Power Battery Pack 3 VDC Caution Certification Label Located on the head sight circumference Identification Label Located on the head sight circumference ...

Page 15: ...GA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows ...

Page 16: ...rs M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industrial pH Conductivity Equipment DATA ACQUISITION M U Communications Based Acquisition Systems M U Data Logging Systems M U Wireless Sensors Transmitters Receivers M U Signal Conditioners M U Da...

Reviews: