Software Installation

Insert the OS100-Soft CD into your computer’s CD-Rom 

drive. The installation program should start up 

automatically. If it does not start automatically locate 

and run the Setup.exe file on the CD.

Microsoft .NET framework 2.0 is a pre-requisite for 

this application and will be automatically installed 

from the CD if missing. This will require you to accept 

the license agreement prior to proceeding.

Navigate through the step-by-step screens until you 

have successfully installed the OS100 software.

The default directory for the executable is: \Programs\

OS100-Soft\OS100-Soft.exe

Please review the software online guide.

RS232 Communication

PC Interface Connection

All commands sent to the OS100E series must be 

terminated by a carriage return or carriage return and 

linefeed, and is shown in this document as “CR” and 

“LF”. Any parameters shown in square brackets “[ ]” are 

optional. Parameters are separated from commands and 

from each other by a space “ “. Spaces within commands 

are shown in this document as “SP”.

ARTWORK/PRODUCT ART/

 DWGS/START HERE ARROW

5

ARTWORK/PRODUCT ART/

 DWGS/START HERE ARROW

6

OS100 SERIES

Mini-Infrared Transmitters

omega.com   [email protected]

®

Servicing North America:

U.S.A.:

 

OMEGA Engineering, Inc., One Omega Dr. 

 

P.O. Box 4047, Stamford, CT 06907-0047 USA 

 

 Toll-Free: 1-800-826-6342 (USA & Canada Only) 

Customer Service: 1-800-622-2378 (USA & Canada Only)  

Engineering Service: 1-800-872-9436 (USA & Canada Only) 

Tel: (203) 359-1660 

Fax: (203) 359-7700 

 

e-mail: [email protected]

For Other Locations Visit omega.com/worldwide

The information contained in this document is believed to be correct, but 

OMEGA accepts no liability for any errors it contains, and reserves the right to 

alter specifications without notice. 

WARNING: These products are not designed for use in, and should not be used  

for, human applications.

RS232 Commands

C Command:

Description: Transmit target temperature in Celsius 

Syntax: C CR [LF]
F Command:

Description: Transmit target temperature in Fahrenheit

Syntax: F CR [LF]
ALARM Command:

Description: Transmit alarm setpoint

Syntax: ALARM CR [LF]
VERSION Command:

Description: Transmit model number, firmware version, 

and output model.

Syntax: VERSION CR [LF]
AMODE Command:

Description: Set/Transmit alarm activation mode 

rising/falling.

Syntax: AMODE [SP MODE] CR [LF]

(Optional) MODE: Specifies whether the alarm will 

activate at the setpoint with rising temperature, or 

falling temperature. The valid range for this parameter 

is 0 to 1. A value of 1 will cause the alarm to activate on 

rising temperature, and 0 will cause activation on falling 

temperature. 

Examples:

Typing “AMODE” and pressing “Enter” does not 

change the activation mode but it is reported.

Typing “AMODE 0” and pressing “Enter” changes the 

activation mode to falling and is reported as such.
EMS Command:

Description: Transmit emissivity setting

Syntax: EMS CR [LF]
CABLE Command:

Description:

Syntax: CABLE [SP LENGTH] CR [LF]

(Optional) LENGTH: Specifies the total length (in feet) 

of cable attached between the sensor head and the 

transmitter box. The valid range for this parameter is 

6 to 56. If this parameter is not specified, the length 

currently set will be transmitted.

Examples:

Typing “CABLE” and then pressing “Enter” does not 

change the current cable length compensation value but 

is reported.

Typing “CABLE 200” and then pressing “Enter” changes 

the current cable length compensation value to 56 

because 200 is above the max length.

For complete product manual:  

www.omega.com/manuals/manualpdf/M3572.pdf

OS101E

OS102E

NOTE:

NOTE:

1

1

3

2

Tx

Tx

Rx

Rx

GND

5

5

6

4

7

9

8

PC SERIAL PORT

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects 

in materials and workmanship for a period of 

13 months

 from 

date of purchase. OMEGA’s WARRANTY adds an additional one (1) 

month grace period to the normal 

one (1) year product warranty

 

to cover handling and shipping time. This ensures that OMEGA’s 

customers receive maximum coverage on each product. 
If the unit malfunctions, it must be returned to the factory for evalua-

tion. OMEGA’s Customer Service Department will issue an Authorized 

Return (AR) number immediately upon phone or written request. 

Upon examination by OMEGA, if the unit is found to be defective, it 

will be repaired or replaced at no charge. OMEGA’s WARRANTY does 

not apply to defects resulting from any action of the purchaser, includ-

ing but not limited to mishandling, improper interfacing, operation 

outside of design limits, improper repair, or unauthorized modifica-

tion. This WARRANTY is VOID if the unit shows evidence of having 

been tampered with or shows evidence of having been damaged as a 

result of excessive corrosion; or current, heat, moisture or vibration; 

improper specification; misapplication; misuse or other operating 

conditions outside of OMEGA’s control. Components in which wear 

is not warranted, include but are not limited to contact points, fuses, 

and triacs.

OMEGA is pleased to offer suggestions on the use of its vari-

ous products. However, OMEGA neither assumes responsibil-

ity for any omissions or errors nor assumes liability for any 

damages that result from the use if its products in accordance 

with information provided by OMEGA, either verbal or writ-

ten. OMEGA warrants only that the parts manufactured by 

the company will be as specified and free of defects. OMEGA 

MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF 

ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT 

THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING 

ANY WARRANTY OF MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. 

LIMITATION OF LIABILITY: The remedies of purchaser set 

forth herein are exclusive, and the total liability of OMEGA 

with respect to this order, whether based on contract, warran-

ty, negligence, indemnification, strict liability or otherwise, 

shall not exceed the purchase price of the component upon 

which liability is based. In no event shall OMEGA be liable for 

consequential, incidental or special damages. 

CONDITIONS: Equipment sold by OMEGA is not intended to be used, 

nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), 

used in or with any nuclear installation or activity; or (2) in medical appli-

cations or used on humans. Should any Product(s) be used in or with 

any nuclear installation or activity, medical application, used on humans, 

or misused in any way, OMEGA assumes no responsibility as set forth 

in our basic WARRANTY/DISCLAIMER language, and, additionally, 

purchaser will indemnify OMEGA and hold OMEGA harmless from any 

liability or damage whatsoever arising out of the use of the Product(s) 

in such a manner.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA 

Customer Service Department.  BEFORE RETURNING ANY 

PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN 

AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER 

SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING 

DELAYS). The assigned AR number should then be marked on the 

outside of the return package and on any correspondence.

OMEGA’s policy is to make running changes, not model changes, 

whenever an improvement is possible. This affords our customers 

the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2014 OMEGA ENGINEERING, INC. All rights reserved.  

This document may not be copied, photocopied, reproduced, 

translated, or reduced to any electronic medium or machine-readable 

form, in whole or in part, without the prior written consent of OMEGA 

ENGINEERING, INC.

MQS357/0314

FOR 

WARRANTY

 RETURNS, 

please have the following 

information available BEFORE 

contacting OMEGA:
1. Purchase Order number 

  under which the product 

  was PURCHASED, 

2. Model and serial number of the 

  product under warranty, and 

3. Repair instructions and/or 

  specific problems relative  

  to the product.

FOR 

NON-WARRANTY

 REPAIRS, 

consult OMEGA for current repair 

charges. Have the following 

information available BEFORE 

contacting OMEGA:
1.  Purchase Order number to cover 

the COST of the repair or 

calibration,

2. Model and serial number of the 

  product, and 

3.  Repair instructions and/or specific 

problems relative to the product.