![Omega ORU50XL Instruction Manual Download Page 7](http://html1.mh-extra.com/html/omega/oru50xl/oru50xl_instruction-manual_4086470007.webp)
7
If your range hood does not function correctly when attempting any of the above, please ensure that your
power is on and is functioning correctly. If the power seems to be functioning correctly in the house, there
may be a problem with the range hood. Please call your authorized Omega service centre in this case to
organize a service call.
Lamp Replacement
1.
Switch the unit off and disconnect from mains power first.
2.
Remove filter and read labels regarding maximum lamp ratings.
3.
Press the light face and remove by turning in anti-clockwise
direction.
4.
Pull out the LED lamp carefully and replace with the same type
and same rated LED LAMP (240V 1.5W MAX).
a. ILCOS-D Code for the lamp is: DBR-1.5/65-H-64
b. Max Wattage: 2 x 1.5W
Cleaning
SAFETY PRECAUTION
Before cleaning your rangehood or performing any maintenance, please ensure that the rangehood is
turned off at the power point.
Do not use abrasive cleaners to clean the rangehood. The use of warm soapy water and a cloth are
recommended.
Ensure that the rangehood is cleaned regularly, as a build-up of grease and fat may occur otherwise.
The filters on the rangehood must be cleaned regularly to maintain efficiency, and prevent grease build up.
The filter mesh is made of a high density Stainless Steel. It is recommended that this is undertaken every 4
– 6 weeks, depending on frequency of use. The filters can be cleaned with warm soapy water or a cloth.
Cleaning of the rangehood must be performed as described above; otherwise there is a possibility of a fire
hazard due to grease and fat build up.
Troubleshooting
Fault
Possible Cause
Solution
Light on, but motor
does not work
Fan switch turned off
Select a fan switch position.
Fan switch failed
Contact Everdure Service.
Motor failed
Contact Everdure Service.
Light does not work,
motor does not work
House fuses blown
Reset/Replace fuses.
Power cord loose or disconnected
Refit cord to power outlet.
Switch power outlet on.
Oil leakage
One-way valve and the air ventilation
entrance are not tightly sealed
Take down the one-way valve and seal with
sealant.
Leakage from the connection of U-shaped
section and cover
Take U-shaped section down and seal.
Lights not working
Broken/Faulty LED lamp
Contact Everdure Service.
Insufficient suction
The distance between the rangehood and
the gas top is too far
Refit the rangehood to the correct distance.
The Rangehood
inclines
The fixing screw not tight enough
Tighten the hanging screw and make it
horizontal.