background image

USA:

One Omega Drive, Box 4047

ISO 9001 Certified

Stamford CT 06907-0047
Tel: (203) 359-1660
FAX: (203) 359-7700
e-mail: [email protected]

Canada: 

976 Bergar
Laval (Quebec) H7L 5A1
Tel: (514) 856-6928 
FAX: (514) 856-6886
e-mail: [email protected]

For immediate technical or application assistance:

USA and Canada:

Sales Service: 1-800-826-6342 
/ 1-800-TC-OMEGA®
Customer Service: 1-800-622- 2378 / 
1-800-622-BEST®
Engineering Service: 1-800-872-9436 / 
1-800-USA- WHEN®
TELEX: 996404 EASYLINK: 62968934 
CABLE: OMEGA

Mexico: 

En Espanol: (001) 203-359-7803 
e-mail: [email protected]
FAX:(001)203-359-7807
[email protected]

Servicing Europe:

Benelux:

Postbus 8034, 1180 LA Amstelveen, The
Netherlands
Tel: +31 (0)20 3472121 
FAX: +31 (0)20 6434643
Toll Free in Benelux: 0800 0993344
e-mail: [email protected]

omega.com®

OMEGAnet® Online Service

www.omega.com

Internet e-mail

[email protected]

Servicing North America:

˜

ɖ

OMEGA®

Czech Republic:

Rudé armády 1868, 733 01 Karviná 8

Tel: +420 (0)59 6311899 
FAX: +420 (0)59 6311114
Toll Free: 0800-1-66342 
e-mail: [email protected]

France:

11, rue Jacques Cartier, 78280 Guyancourt,
France
Tel: +33 (0)1 61 37 29 00
FAX: +33 (0)1 30 57 54 27
Toll Free in France: 0800 466 342
e-mail: [email protected]

Germany/Austria: 

Daimlerstrasse 26, D-75392 Deckenpfronn,
Germany
Tel: +49 (0)7056 9398-0 
FAX: +49 (0)7056 9398-29
Toll Free in Germany: 0800 639 7678
e-mail: [email protected]

United Kingdom:

One Omega Drive, River Bend Technology

ISO 9002 Certified

Centre
Northbank, Irlam, Manchester
M44 5BD United Kingdom
Tel: +44 (0)161 777 6611 
FAX: +44 (0)161 777 6622
Toll Free in United Kingdom: 
0800-488-488
e-mail: [email protected]

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI
regulations that apply. OMEGA is constantly pursuing certification of its products
to the European New Approach Directives. OMEGA will add the CE mark to every
appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA
Engineering, Inc. accepts no liability for any errors it contains, and reserves the
right to alter specifications without notice.

WARNING:

These products are not designed for use in, and should not be used

for, patient-connected applications.

button again to exit the set up screen. For information relating to
the emissivity of specific materials, please contact the nearest
retailer. Note: non- contact infrared thermometers are not
recommended for use in measuring the temperature of shiny or
polished metals.

LCD ERROR MESSAGES

The OS-SF incorporates visual diagnostic messages as follows:
Hi or  Lo  is displayed when the temperature being measured
is outside of the range of the instrument,  Hi when higher than
+110

ƨ

(230

Ʃ

) and  Lo  when lower than -22

ƨ

(-8

Ʃ

).

Er2  is displayed when the OS-SF is
exposed to rapid changes in the ambient
temperature.  Er3 is displayed when the
ambient temperature of the OS-SF
exceeds -10 or +50

ƨ

(14 or 122

Ʃ

). In

both cases you should allow plenty of
time (minimum 30 minutes) for the OS-
SF to stabilize to the working/room
temperature (0 to +40

ƨ

, 32 to 104

Ʃ

).

For all other error messages it is necessary to reset the OS-SF. To
reset the OS-SF, turn the instrument off remove the battery and
wait for a minimum of one minute, reinsert the battery and turn
on. if the error message remains please contact the Service
Department for further assistance.

BATTERIES

The OS-SF incorporates visual low battery indication as follows:

"Battery OK"
measurements are
possible

"Battery Low" battery
needs to be replaced,
measurements are
possible

"Battery Exhaused"
measurements are  not
possible

OS-SF Thermometer Operating Instructions

The OS-FS thermometer is a non-contact infrared thermometer.
Simply aim the thermometer at the target and press the
measurement button to display the surface temperature. The
distance to target ratio is 1:1 therefore the thermometer should be
positioned as close to the target as possible.

ƨ

OR 

Ʃ

MODE

To change the OS-SF from 

ƨ

to  

Ʃ

or from  

ƨ

to  

Ʃ

, first turn

the instrument on by pressing the measurement button, then press
the mode button four times, the 

ƨ

or 

Ʃ

symbol will flash, press

the measurement key to change to scale, then press the
measurement button to confirm the mode.

MINIMUM OR MAXIMUM MODE

To  utilize the OS-SF's minimum or maximum mode, firstly turn
the instrument on by pressing the measurement button, then press
the mode button once for minimum or twice for maximum
function. The MIN or MAX icon will flash, then press the
measurement button to confirm the minimum or maximum mode.
The OS-SF will display the minimum or maximum reading only.

LOCK MODE

The lock mode is particularly useful for continuous monitoring of
temperatures. To utilize the OS-SF's lock mode, firstly turn the
instrument on by pressing the measurement button, then press the
mode button three times for the lock mode function. The lock icon
will flash, then press the measurement button to confirm the lock
measurement mode. The OS-SF will continuously display the
temperature for up to 60 minutes or until the measurement button
is pressed.

EMISSIVITY

The OS-SF infrared thermometer is supplied with a default
emissivity of 0.95. The emissivity of the OS-SF can be changed
from 0.01 (1E) to 1 (100E). Changes should only be carried out by
experienced personnel. To change the OS-SF's emissivity firstly
turn the instrument on by pressing the measurement button, then
press the mode button five times for emissivity function.
The 95E Will flash on the LCD screen, then press the
measurement button to adjust the emissivity value, press the mode