User’s Guide

HH147AU

THERMOMETER

TM

Summary of Contents for HH147AU

Page 1: ...e mail info omega com For latest product manuals www omegamanual info Shop online at omega com User sGuide HH147AU THERMOMETER TM ...

Page 2: ...erves the right to alter specifications without notice Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Canada only Engineering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide ...

Page 3: ...5 4 Manual Record Rec 4 5 5 Data Hold 5 5 6 Auto Power Off 5 5 7 Relative Value Measurement 6 5 8 Offset Setting OFFSET 7 5 9 T1 T2 Display 8 5 10 Maximum Minimum Average Value 9 5 11 FunctionSettings Step1 Step5 10 6 Software Installation 14 7 General Specifications 16 8 Electrical Specifications 17 9 Maintenance and Repair 18 10 Battery Replacement 18 11 Product disposal 18 ...

Page 4: ... the meter and its components Complies with European Directive Do not operate in environments with flammable gas or humid environments Operating altitude up to 2000M Operating environment Indoor use Pollution degree 2 Clean with soft cloth when dirty such as glasses cloth Do not clean with chemicals and other solvents EMC EN61326 1 CISPR 11 Group 1 Class B Class B Equipment for use in all establis...

Page 5: ...y 4 Unit C F K alarm switch button 5 Maximum value Minimum value Average value elapsed time Setup button 6 K J T E R S N type switching record single data button 7 Hold auto power off button 8 Relative value offset value button 9 Power backlight button 10 T1 T2 T1 and T2 top and bottom switch button 11 Battery installation 12 Battery cover 13 DC 9V input 14 Data output socket ...

Page 6: ...he LCD 5 1 Backlight While under ON status Press and hold the button for over 2 seconds to turn on the backlight press and hold the button for over 2 seconds again to turn off the backlight function The backlight will automatically turn off after being lit for 15 seconds 5 2 Alarm Function Press and hold the button for 2 seconds and the LCD will display whether the alarm function is ON or OFF A ma...

Page 7: ...le type will switch in the order of K J E T R S N 5 4 Manual Record Rec Press and hold the button for over 2 seconds to save 1 temperature data 00001 will be displayed on the LCD and will increase by 1 every time it is pressed Repeat this process the manual record will continue to add 1 0002 will be displayed ...

Page 8: ...ata and stop updating When HOLD is enabled all buttons will stop working except for the power button 5 6 Auto Power Off The device is preset to automatically shut down after 15 minutes of inactivity Press button more than 1 second to turn on or turn off auto power off ...

Page 9: ...w and the LCD will display 0 C then a second temperature was measured to be 30 C and the LCD will display 5 C 30 25 5 C Press the button again to turn off this function The main display shows the REL value and the secondary display shows the temperature value currently being measured To display the relative value of another channel please press and hold the button to switch between T1 and T2 displ...

Page 10: ... the offset value 2 Press the top and bottom buttons to increase or decrease the offset value the unit for every time it is pressed is 0 1 C F K The setting range is between 5 C 5K and 9 F 3 Press the Setup button to save the setting and exit the setting mode To set the offset for another channel please press the button to switch The device will automatically save the offset value set as the defau...

Page 11: ...s the button again to turn off this function The main display will display the T1 T2 value and the secondary display will display the temperature value currently measured To display the temperature measured on another channel on the secondary display please press and hold the button to switch Every time the button is pressed and held the main secondary display position of T1 and T2 will be switche...

Page 12: ... as shown in the figure below Press and hold the button for over 1 second to turn off this function The main display will display the MAX MIN or AVG value of the current channel and elapsed time for the measurement the secondary display will display the current temperature value To display the maximum value minimum value and mean value of another channel please press and hold the button to switch ...

Page 13: ... Lo 2 Press the button to select T1 or T2 and Hi or Lo symbol and the button to select the digit 3 Press the button or bottom button to set the temperature and positive negative symbol 4 The setting of the High and Low bottom limit is based on the measurement range and it will automatically determine whether the temperature exceeded the limits 5 Press the Setup button to save the settings and go t...

Page 14: ...tton to select ON OFF or adjust the hour minute and second 2 Press the Setup button to save the settings and go to Step 3 Time Setting STEP 3 1 Press the left or buttons to select hour minute second year month and day 2 Press the top or button to adjust the time 3 Press the Setup button to save the settings and go to Step 4 ...

Page 15: ... 4 USB ON OFF Setting 1 Press the or buttons to select USB ON OFF 2 Press the Setup button to save the settings and go to Step 5 PS Please turn off the USB when not in use in order to save battery consumption ...

Page 16: ...the previous or next record Press the button to view the time and temperature for this record Please press the button to switch the display of T1 and T2 between the main and secondary displays Clear record Press the button and CLR will start flashing on the screen press the button to confirm clearing all records ...

Page 17: ...tware Installation OS Windows XP 7 8 10 operating systems Install the CD into the PC to install the software first Connect the USB cable to connect the meter and the computer according to the drawing USB CABLE ...

Page 18: ...15 Select the desktop icon and click twice on left key of the mouse to run the procedure ...

Page 19: ... records Save interval 1 second 24 hours Low battery display Battery 9V alkaline battery NEDA 1604 IEC 6F22 or JIS 006P AC to DC Adaptor External AC 100 240V to DC 9V 0 5A power supply Plug The pin in the center connects to the positive electrode and the outer case is negative electrode Diameter 5 5mm internal diameter 2 1mm Battery life Approximately 100 hours Operation temperature and humidity 0...

Page 20: ...C to 1300 C 238 F to 2372 F Resolution 0 1 K J T E N 1 R S Accuracy K J E T N Type 0 05 rdg 0 7 C 1 4 F 250 C to 100 C 418 F to 148 F 0 05 rdg 0 7 C 1 F 100 to 1372 C 148 to 2501 F R S Type 0 05 rdg 2 C 4 F 0 C to 1767 C 32 F to 3212 F Temperature coefficient 0 01 0 03 C of read value C 0 06 F F outside 18 C to 28 C 64 F to 82 F specified range Under 100 C 148 F 0 04 of read value added to K J T E...

Page 21: ...y if not used for a long period of time in order to prevent battery leakage and causing damages to internal components 4 When the instrument failure only by the authorized service provider or return the original repair 10 Battery Replacement 1 Turn off the power 2 Open the battery cover at the back of the meter remove the battery 3 Please insert a new 9V battery according to the polarities 4 Put t...

Page 22: ...1 9 ...

Page 23: ...pecification misapplication misuse or other operating conditions outside of OMEGA s control Components in which wear is not warranted include but are not limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from th...

Page 24: ...M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industrial pH Conductivity Equipment DATA ACQUISITION M U Communications Based Acquisition Systems M U Data Logging Systems M U Wireless Sensors Transmitters Receivers M U Signal Conditioners M U Data Acquisition Software HEATERS M U Heating Cable M U Cartridge Strip Heaters M U Immersion Band Heaters M U Flexible Heat...