background image

HH12C 

DIGITAL THERMOMETER

Servicing North America: 

U.S.A. Omega Engineering, Inc. 

Headquarters: Toll-Free: 1-800-826-6342 (USA & Canada only) 

Customer Service: 1-800-622-2378 (USA & Canada only) 

Engineering Service: 1-800-872-9436 (USA & Canada only) 

Tel: (203) 359-1660 Fax: (203) 359-7700 

e-mail: [email protected]

For Other Locations Visit omega.com/worldwide

It is the policy of OMEGA Engineering, Inc. to comply with all 
worldwide safety and EMC/EMI regulations that apply. OMEGA is 
constantly pursuing certification of its products to the 
European New Approach Directives. OMEGA will add the CE 
mark to every appropriate device upon certification. 
The information contained in this document is believed to be 

correct, but OMEGA accepts no liability for any errors it 
contains, and reserves the right to alter specifications without 
notice. 
WARNING: These products are not designed for use in, and 
should not be used for, human applications. 

INTRODUCTION

This  instrument  is  a  portable  4½  digit,  compact-sized 

digital thermometer  designed to use  external K-type 

thermocouples as temperature  sensor.  Temperature 

indication  follows  National  Bureau  of  Standards  and 

IEC  584  temperature/voltage  tables  for  K-type 

thermocouples. 

Two  K-type  thermocouple  are 

supplied with the thermometer.

SAFETY INFORMATION 

It is recommended that you read the safety and 

operation instructions before using this thermometer. 

WARNING 

To avoid electrical shock, do not use this 

instrument when working voltages at the 

measurement surface over 24V AC or 60V DC.

WARNING 

To avoid damage or burns, do not make temperature 

measurement in microwave ovens.

CAUTION 

Repeated sharp flexing can break the thermocouple 

leads. To prolong lead life, avoid sharp bends in the 

leads, especially near the connector.

The 

  symbol  on  the  instrument  indicates  that  the 

operator must refer to an explanation in this manual. 

SPECIFICATIONS 

ELECTRICAL

Temperature Scale:

 Celsius or Fahrenheit user-selectable 

Measurement Range: 

-200°C to 1372°C, -328°F to 2501°F

Auto range: 

0.1°C/1°C, 0.1°F/1°F 

Accuracy:

Accuracy  is  specified  for  operating  tempera-

tures over the range of 18°C to 28°C (64°F to 82°F), for 

1 year, not including thermocouple error. 

±(0.1%rdg+0.5°C) on -50°C to 1372°C 

±(0.1%rdg+2°C) on -50°C to -200°C 

±(0.1%rdg+1°F) on -58°F to 2501°F 

±(0.1%rdg+4°F) on -58°F to -328°F 

Temperature Coefficient: 

0.1  times  the  applicable  accuracy  specification  per  °C 

from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 

82°F to122°F). 

Input Protection: 

60V dc or 24V ac rms maximum input voltage on any 

combination of input pins. 

Input Connector:   

Accepts  standard  miniature  thermocouple  connectors 

(flat blades spaced 7.9mm, center to center). 

ENVIRONMENTAL 

Ambient Operating Ranges: 

0°C to 50°C (32°F to 122°F) <80% R.H. 

Storage Temperature: 

-20°C to 60°C (-4°F to 140°F) <70% R.H.

GENERAL 

Display:

 4½ digit liquid crystal display (LCD) with max-

imum reading of 19999. 

Low battery indication:

 The “

” is displayed when the 

battery voltage drops below the operating level. 

Measurement rate:

 1 time/second. 

Operating environment:

 0°C to 50°C at<70% R.H. 

Storage temperature:

 -20°C to 60°C, 0 to 80% R.H. with 

battery removed from meter. 

Accuracy:

 Stated accuracy at 23°C±5°C, <75% R.H. 

Battery:

 Standard 9V battery (NEDA 1604, IEC 6F22). 

Battery Life:

 100 hours typical with carbon zinc battery. 

Dimensions:

 210mm(H) x 65mm(W) x 35mm(D). 

Weight:

 approx. 292g including battery. 

Supplied Wire: 

4 feet type “K” thermocouple bead wire 

(

PTFE

  tape  insulated).  Maximum  insulation  tempera-

ture  260°C  (500°F).  Wire  accuracy  ±2.2°C  or  ±0.75% 

of reading (whichever is greater) from 0°C to 800°C. 

OPERATING INSTRUCTIONS

1.

“°C/°F” Button: Selecting the Temperature Scale

Reading are  displayed in either  degrees  Celsius(°C)

 

or 

degrees Fahrenheit(°F).  When the thermometer is

turned on, it is set to the temperature scale that was in

use when the thermometer was last turned off. 

2.

Single-Thermocouple Temperature

 

Measure-

ment 

The  thermometer  displays  the  temperature  of  the 

thermocouple  that  is  connected  to  the  selected  input. 

Press  the  “T2”  key  to  display  the  temperature  of  the 

thermocouple connected to the T2 input. Press the “T1” 

key  to  display  the  temperature  of  the  thermocouple 

connected  to  the  T1  input.  The  input  selection  cursor 

indicates which input is selected. 

3.

T2 or Differential Temperature Measurement

T2  thermocouple or  Differential temperature 

measurement is  selected by  pressing the “T2/T1-T2”

key.

 

This causes the thermometer to display the

temperature

 

difference between the two thermocouples

(the temperature  of thermocouple T1  minus the

temperature  of

 

thermocouple T2). The selection is

indicated by the input selection cursor. 

4.

“HOLD” Button

Press the “HOLD” key to enter the Data Hold mode,

the  “HOLD”  annunciator  is  displayed.  When  HOLD

mode is  selected,  the thermometer  held the present

readings and stops all further measurements. Press  the

“HOLD”  key  again  cancels  HOLD  mode,  causing  the

thermometer to resume taking measurements.

5.

“REL” Button

Press “REL”  key to enter Relative  mode,  zero the

display,  and store  the displayed  reading  as  a  reference

value and annunciator  REL  is  displayed.  Pressing

“REL” key over 2 seconds to exit the relative mode.

 