background image

DRC-4720

Bridge Input Signal Conditioner

INSTRUCTION

SHEET

M4739/0109

Shop online at: omega.com   e-mail: [email protected]
For latest product manuals: omegamanual.info

Description:

The DRC-4720 is a DIN Rail mount, self-contained DC 
powered module designed for load cell, strain gage, or 
single ended use. The DRC-4720 contains a precision 
instrumentation amplifier, filtered output and a built-
in 10V excitation supply capable of driving a 350 ohm 
bridge. The 0 to 30mV input range makes it compatible 

with most strain gage based load cell or pressure 
transducer outputs. The DRC-4720 provides an output of 
4 to 20mA. Connections are made via easily accessible 
screw clamp terminal blocks. Zero and Span adjustment 
potentiometers are located externally as well for easy 
access.

Amplifier

Gain
     Input for a 20mA Output

10mV to 30mV

Linearity: 4 to 20mA Out

±0.01

Temperature Coefficient

0.05% / ºC

Input Offset Voltage
     Temperature Coefficient

±70μV

0.7μV / ºC

Common Mode Voltage

0 to +5 Volts

Common Mode Rejection - DC

100 dB

Input Noise
     0.1Hz to 10Hz

0.3μV pp Typ

Output

Output Range

4 to 20mA

Compliance Voltage

5.5V Max

Loop Resistance

250Ω Max

Frequency Response
     2 Pole Filter

DC to 10Hz

Total RMS Gain
Temperature Coefficient

0.007% / ºC

Bridge Supply

Fixed Output

+10V ±1.5%

Temperature Coefficient

0.05% / ºC

Load Current

30mA Max

Power Requirements

Voltage

18 to 26 Volts

Input Current (1 - 350 Ohm Bridge)

55 mA

Environment

Operating Temperature

0ºC to +55ºC

Storage Temperature

-40ºC to +80ºC

Size

Size
(Not including Universal Foot for 
standard DIN EN Rails)

1.65”H x 1.06”W x 3.78”L

(42 x 27 x 96mm)

Weight

3 oz. (85g)

Agency Approval

UL, CE

UL508, UL1604, CE

Pending

Features:

Low Cost
Din Rail Mount
Load Cell or Single Ended Application
4-20mA

Reviews: