START HERE
2
3
4
Using This Quick Start Manual
Use this Quick Start Manual to set up your meter and
begin operation. Information is provided on how to:
¥
Connect ac power
¥
Connect the RTD
¥
Set basic options for operation
For complete information on all setup options, please
see the OperatorÕs Manual.
Before You Begin
In addition to the meter and the related parts, you will
need the following items to set up your unit:
¥
ac power, as listed on meterÕs ID/Power Label
¥
RTD
¥
1
Ú
8
Ó flat blade screwdriver
Mount the Unit
1.
Cut a panel opening using
the dimensions shown
below.
2.
Position the meter in the
opening, making sure the
front bezel is flush with the panel.
Connect ac Power
Warning: Do not connect ac power to your meter
until you have completed all input and output
connections. Failure to do so may result in injury!
1.
Remove the panel at the back of the meter.
2.
Locate the TB1 connector.
3.
Insert the correct wire in each terminal as shown
in the following figure and tighten the lockdown
screws. Tug gently on the wires to verify
connections.
Main ac Power Connections
To Set the RTD Type:
1.
Press
MENU
until the meter
displays:
2.
Press
䊳
/DEV
. The meter
displays:
3.
Press
䊱
/T1/T2/
until the RTD for your
installation is shown. The choices are:
¥
385.2 - 2-wire DIN
¥
385.3 - 3-wire DIN (default)
¥
385.4 - 4-wire DIN
¥
392.2 - 2-wire NIST
¥
392.3 - 3-wire NIST
¥
392.4 - 4-wire NIST.
4.
Press
MENU
to select the RTD shown. The meter
displays:
Turn on the Meter
1.
Apply ac power to the unit.
The unit initializes, flashing the following
messages on the front panel:
RST
,
D.RTD
. Then
the temperature should display.
2.
Verify that a temperature is displayed. If not:
¥
Remove ac power from the unit.
¥
Verify the TB1 power connections.
¥
Check your power source.
¥
Apply ac power again.
Configure the Unit
To configure the meter, use the buttons on the front
panel.
To:
Take This Action
Display the
Press the
MENU
button.
Configuration
The first function on the
Menu.
menu,
INPT
, displays.
Select the
1. Press
MENU
until the
submenu
function you want is shown.
function
2. Press
䊳
/DEV
.
The information you can change
begins to flash.
Select a value
1. Press
䊱
/T1/T2/
to display
for that
the option you want.
submenu
2. Press
MENU
to select it.
function
The message
STRD
quickly
flashes, indicating that the
selection has been stored in
memory. Then the next
menu function displays.
on
Go back to the
Press
RESET
once.
previous menu
function.
Exit the
¥ Press
RESET
twice. The
Configuration
meter reinitializes (displays
Menu.
RST
, then
D.RTD
). When the
temperature displays, the
meter is in run mode.
¥ Optionally, you can press
MENU
to move through all
the menu functions until the
meter reinitializes.
Connecting the RTD
1.
Locate the TB4 (or TB2, depending on your unit)
connector on the rear of the unit (see the figure
above).
2.
Attach the RTD wires, referring to the appropriate
diagram below and tighten down lockdown
screws.
3.
Tug gently on the wires to verify the connections.
4.
Replace the panel at the back of the unit.
2-Wire RTD Input Connection
3-Wire RTD Input Connection
4-Wire RTD Input Connection
1
2
3
8
4
5
7
6
RTD
RTD
4
3
1
2
+S1
+E1
5
-S1 -E1
6
7
RTD
+E2 +S2
-S2 -E2
RTD
Channel 1
Channel 2
Version #1-TB4
Version #2-TB2
8
Channel 2
Channel 1
+E1
+S1 MGND +R1 +R2 MGND +S2 +E2
+S1
2
1
1
2
3
8
4
5
7
6
RTD
RTD
+E1
5
+E2 +S2
3
4
-E1
-S1
7
6
RTD
-S2 -E2
RTD
Channel 1
Channel 2
Version #1-TB4
Version #2-TB2
8
Channel 2
Channel 1
+E1 +S1 MGND +R1 +R2 MGND +S2 +E2
1
3
2
4
5
6
7
8
RTD
Channel 1
Channel 2
RTD
Version #2-TB2
6
5
1
2
7
3
4
+S2
-E2
+E1 +S1
-S1 -E1
+E2
-S2
RTD
Version #1-TB4
RTD
8
Channel 2
Channel 1
+E1 +S1 MGND +R1 +R2 MGND +S2 +E2
45,00 + 0,61/-0,00
(1.772 + .024/Ð.000)
92,00 + 0,81/Ð0,00
(3.622 + .032/Ð.000)
PANEL THICKNESS
1,5
R(.06)
4 PLCS
6,4 (.25) MAX
0,8 (.03) MIN
NOTE: Dimensions in Millimeters (Inches)
䊳
SETPTS
/DEV
MENU
RESET
䊱
/T1/T2
䊳
SETPTS
/DEV
MENU
RESET
䊱
/T1/T2
䊱
䊳
SETPTS
/DEV
MENU
RESET
/T1/T2
䊳
SETPTS
/DEV
MENU
RESET
䊱
/T1/T2
12502ML-98A_DP26RTD_OMG.qxd 8/16/99 9:36 AM Page 1