Using This Quick Start Manual

Use this Quick Start Manual to set up your meter and
begin operation.  Information is provided on how to:
¥

Connect ac power

¥

Connect the RTD

¥

Set basic options for operation

For complete information on all setup options, please
see the OperatorÕs Manual.

Before You Begin

In addition to the meter and the related parts, you will
need the following items to set up your unit:
¥

ac power, as listed on meterÕs ID/Power Label

¥

RTD 

¥

1

Ú

8

Ó flat blade screwdriver

Mount the Unit

1.

Cut a panel opening using
the dimensions shown
below.

2.

Position the meter in the
opening, making sure the
front bezel is flush with the panel.

Connect ac Power

Warning: Do not connect ac power to your meter
until you have completed all input and output
connections. Failure to do so may result in injury!

1.

Remove the panel at the back of the meter.

2.

Locate the TB1 connector.

3.

Insert the correct wire in each terminal as shown
in the following figure and tighten the lockdown
screws.  Tug gently on the wires to verify
connections.

Main ac Power Connections

To Set the RTD Type:

1.

Press 

MENU

until the meter

displays:

2.

Press  

/DEV

. The meter

displays:

3.

Press 

/T1/T2/

until the RTD for your

installation is shown. The choices are:

¥

385.2 - 2-wire DIN

¥

385.3 - 3-wire DIN (default)

¥

385.4 - 4-wire DIN

¥

392.2 - 2-wire NIST

¥

392.3 - 3-wire NIST

¥

392.4 - 4-wire NIST.

4.

Press 

MENU

to select the RTD shown. The meter

displays:

Turn on the Meter

1.

Apply ac power to the unit. 

The unit initializes, flashing the following
messages on the front panel: 

RST

D.RTD

. Then

the temperature should display.

2.

Verify that a temperature is displayed.  If not:

¥

Remove ac power from the unit.

¥

Verify the TB1 power connections.

¥

Check your power source.

¥

Apply ac power again.

Configure the Unit

To configure the meter, use the buttons on the front
panel.

To:

Take This Action

Display the

Press the 

MENU

button.

Configuration

The first function on the

Menu.

menu, 

INPT

, displays.

Select the 

1. Press 

MENU

until the

submenu

function you want is shown.

function 

2.  Press 

/DEV

.

The information you can change
begins to flash.

Select a value

1.  Press  

/T1/T2/

to display

for that

the option you want.

submenu 

2.  Press 

MENU

to select it.

function

The message 

STRD

quickly 

flashes, indicating that the 
selection has been stored in 
memory.  Then the next
menu function displays.

on

Go back to the

Press 

RESET

once.

previous menu
function.

Exit the 

¥    Press 

RESET

twice.  The 

Configuration

meter reinitializes (displays 

Menu.

RST

, then 

D.RTD

). When the

temperature displays, the
meter is in run mode.

¥    Optionally, you can press 

MENU

to move through all

the menu functions until the
meter reinitializes.

Connecting the RTD

1.

Locate the TB4 (or TB2, depending on your unit)
connector on the rear of the unit (see the figure
above).

2.

Attach the RTD wires, referring to the appropriate
diagram below and tighten down lockdown
screws.

3.

Tug gently on the wires to verify the connections.

4.

Replace the panel at the back of the unit.

2-Wire RTD Input Connection

3-Wire RTD Input Connection

4-Wire RTD Input Connection

1

2

3

8

4

5

7

6

RTD

RTD

4

3

1

2

+S1

+E1

5

-S1 -E1

6

7

RTD

+E2 +S2

-S2 -E2

RTD

Channel 1

Channel 2

Version #1-TB4

Version #2-TB2

8

Channel 2

Channel 1

+E1

+S1 MGND +R1 +R2 MGND +S2 +E2

+S1

2

1

1

2

3

8

4

5

7

6

RTD

RTD

+E1

5

+E2 +S2

3

4

-E1

-S1

7

6

RTD

-S2 -E2

RTD

Channel 1

Channel 2

Version #1-TB4

Version #2-TB2

8

Channel 2

Channel 1

+E1 +S1 MGND +R1 +R2 MGND +S2 +E2

1

3

2

4

5

6

7

8

RTD

Channel 1

Channel 2

RTD

Version #2-TB2

6

5

1

2

7

3

4

+S2

-E2

+E1 +S1

-S1 -E1

+E2

-S2

RTD

Version #1-TB4

RTD

8

Channel 2

Channel 1

+E1 +S1 MGND +R1 +R2 MGND +S2 +E2

45,00  + 0,61/-0,00

(1.772  + .024/Ð.000)

92,00  + 0,81/Ð0,00

(3.622  + .032/Ð.000)

PANEL THICKNESS

1,5

R(.06)

4 PLCS

6,4 (.25) MAX
0,8 (.03) MIN

NOTE: Dimensions in Millimeters (Inches)

SETPTS

/DEV

MENU

RESET

/T1/T2

SETPTS

/DEV

MENU

RESET

/T1/T2

SETPTS

/DEV

MENU

RESET

/T1/T2

SETPTS

/DEV

MENU

RESET

/T1/T2

12502ML-98A_DP26RTD_OMG.qxd  8/16/99  9:36 AM  Page 1

Reviews: