background image

An  O ME GA Te c h n o l o g i e s  Co m p a n y

 M2114/1294

INSTRUCTION

SHEET

DP18 Series

Model DP18-P7
Process Indicator

CCD1294APC1B

1

10

D
C
B
A

+

-

REAR VIEW

Setpoint R1
(option)

Setpoint R2
(option)

FRONT VIEW

FIG. 2

FIG. 1

SIGNAL
INPUT

SPAN : ADJUST THE MAXIMUM READING.
OFFSET : ZERO ADJUST

SPAN AND OFFSET ADJUSTMENT ARE ACCESSIBLE BEHIND
THE LOW DOOR.

Isolated digital output

(option)

HOLD,

 latch the reading

display, while these pins
are linked

ANALOG OUTPUT
(OPTION)

POWER SUPPLY

see instrument label

SPAN

OFFSET

FIG. 3

DISPLAYS . . . . . . . . . . . . . . . . . . . . . .  3 ½   digits, 7 segment, red LED
HEIGHT . . . . . . . . . . . . . . . . . . . . . . . .  0.56" (14.2 mm.)
SYMBOLS . . . . . . . . . . . . . . . . . . . . . .  ± 1.8.8.8
DECIMAL POINTS . . . . . . . . . . . . . . . .  Selectable by jumpers
OVERRANGE INDICATION . . . . . . . . .  Display flashes 1999

INPUT CONFIGURATION . . . . . . . . . . .  Bipolar single
ZERO . . . . . . . . . . . . . . . . . . . . . . . . .  Automatic
SPAN ADJUSTMENT . . . . . . . . . . . . . .  ± 5 %

CONVERTER . . . . . . . . . . . . . . . . . . . .  Dual-slope, average value
POLARITY . . . . . . . . . . . . . . . . . . . . . .  Automatic  ±
SIGNAL INTEGRATION PERIOD . . . . .  80 ms.
READ RATE . . . . . . . . . . . . . . . . . . . .  3.12 / sec.
RANGES . . . . . . . . . . . . . . . . . . . . . . .  See table fig. 3
HOLD . . . . . . . . . . . . . . . . . . . . . . . . .  Optional

NOISE REJECTION NMR . . . . . . . . . . .  50 dB. 50/60 Hz.
ACCURACY . . . . . . . . . . . . . . . . . . . .  0.15 %   ± 1 count
WARMUP TO RATED ACCURACY .  .  .  2  minutes
SPAN TEMPCO . . . . . . . . . . . . . . . . . .  100 ppm.
ZERO TEMPCO . . . . . . . . . . . . . . . . . .  2.5 µV/°C.

OPERATING TEMPERATURE . . . . . . .  0 to 50 °C (32 to 122 °F)
STORAGE TEMPERATURE . . . . . . . . .  -40 to 80 °C (-40 to 176 °F)
WEIGHT . . . . . . . . . . . . . . . . . . . . . . . .  310 gr. (0.68 lb)
CASE MATERIAL . . . . . . . . . . . . . . . .  ABS, DIN 43700, black color
STANDARD POWER . . . . . . . . . . . . . .  115 Vac. ± 10 %, 50/60 Hz.
POWER CONSUMPTION . . . . . . . . . . .  5.5 VA for AC. / 3.5 W. for DC.

ELECTRICAL CONNECTIONS . . . . . . .  Push-in cable connectors
BURN-IN . . . . . . . . . . . . . . . . . . . . . . .  24 h.
AUXILIARY VOLTAGE . . . . . . . . . . . .  10 to 24 Vdc. adjustable
Max.  current . . . . . . . . . . . . . . . . . . . .  50 mA
Ripple at 50/60 Hz. . . . . . . . . . . . . . . .  0.2 % Maximum

SPECIFICATIONS

SELECTOR S1

A

B

C

D

SELECTOR S3

Õ

Ö

EXCITATION ADJUST
FOR TRANSDUCER

COMPONENTS VIEW

GROSS SPAN ADJUST

OFFSET

O

M

RANGE SELECTION FOR SPAN AND OFFSET  ( S3 SELECTOR )

OFFSET TRAVEL

SPAN TRAVEL

L

K

---

500  to  1.000

0  to     500

1.000  to  1.999

1.000  to  2.000

 CLOSE
JUMPER

CLOSE
JUMPER

 P

 --

 N

MAXIMUM
READING

MAXIMUM
READING

500  to  1.000

0  to    500

RANGE SELECTION (SELECTOR S1)

0 - 200

0 - 20

RANGE
   Vdc.

 CLOSE
JUMPER

  D

-----

SIGNAL CONDITIONER

K
L
M
N
O
P

SIGNAL INPUT CONNECTIONS AND CONFIGURATION PROCEDURES

DC INSTRUMENT 3 ½ DIGITS, FOR SIGNAL INPUT IN Vdc UP TO 200 Vdc, IN TWO RANGES SELECTABLE ON THE SIGNAL CONDITIONER
BY PLUG-IN JUMPERS. ALLOWS THE READING TO BE DISPLAYED IN ENGINEERING UNITS, USING THE TRIMMERS AND SELECTABLE
RANGES FOR SPAN AND OFFSET (see fig.3).
PROVIDES AN EXCITATION OUTPUT FOR TRANSDUCERS ADJUSTABLE FROM 10 TO 24 Vdc BY A TRIMMER.

CLOSE THE APPROPRIATE DECIMAL POINT JUMPER (FIG.5), CORRESPONDING TO THE
READING DESIRED. FOR A READING OF 14.50 PLACE THE JUMPER ON THE D2 POSITION.

OUTPUT V

EXC.

  (10-24 V.)

COMMON 0 V.

SIGNAL INPUT

SELECT THE DESIRED RANGE,
CLOSING THE APPROPRIATE JUM-
PER (SELECTOR S1) ON THE
SIGNAL CONDITIONER.