background image

An  O ME GA Te c h n o l o g i e s  Co m p a n y

 M2105/1294

INSTRUCTION

SHEET

DP18 Series

Models DP18-AC1 / -AC2 / -AC3 / -AC4
AC Milliammeter

CCD1294APC2BA

DISPLAYS . . . . . . . . . . . . . . . . . . . . . .  3       digits, 7 segment, red LED
HEIGHT . . . . . . . . . . . . . . . . . . . . . . . .  0.56" (14.2 mm.)
SYMBOLS . . . . . . . . . . . . . . . . . . . . . .  1.8.8.8
DECIMAL POINTS . . . . . . . . . . . . . . . .  Selectable by jumpers
OVERRANGE INDICATION . . . . . . . . .  Display flashing 1999

INPUT CONFIGURATION . . . . . . . . . . .  Bipolar single
ZERO . . . . . . . . . . . . . . . . . . . . . . . . .  Automatic
SPAN ADJUSTMENT . . . . . . . . . . . . . .  ± 5 %

CONVERTER . . . . . . . . . . . . . . . . . . . .  Dual-slope, average value
SIGNAL INTEGRATION PERIOD . . . . .  80 ms.
READ RATE . . . . . . . . . . . . . . . . . . . .  3.12 / sec.
RANGES . . . . . . . . . . . . . . . . . . . . . . .  See table selection
HOLD . . . . . . . . . . . . . . . . . . . . . . . . .  Optional

NOISE REJECTION NMR . . . . . . . . . . .  50 dB. 50/60 Hz.
ACCURACY . . . . . . . . . . . . . . . . . . . .  0.2 % ± 1 count
WARMUP TO RATED ACCURACY .  .  .  2  minutes
SPAN TEMPCO . . . . . . . . . . . . . . . . . .  150 ppm.
ZERO TEMPCO . . . . . . . . . . . . . . . . . .  2.5 µV/°C.

OPERATING TEMPERATURE . . . . . . .  0 to 50 °C (32 to 122 °F)
STORAGE TEMPERATURE . . . . . . . . .  -40 to 80 °C (-40 to 176 °F)
WEIGHT . . . . . . . . . . . . . . . . . . . . . . . .  310 gr. (0.68 lb)
CASE MATERIAL . . . . . . . . . . . . . . . .  ABS, DIN 43700, black  color
STANDARD POWER . . . . . . . . . . . . . .  115 Vac. ± 10 %, 50/60 Hz.
POWER CONSUMPTION . . . . . . . . . . .  5.5 VA for AC.
ELECTRICAL CONNECTIONS . . . . . . .  Push-in cable connectors
BURN-IN . . . . . . . . . . . . . . . . . . . . . . .  24 h.

SPAN

OFFSET

1

10

D
C
B
A

+

-

REAR VIEW

Setpoint R1
(option)

Setpoint R2
(option)

FRONT VIEW

FIG. 2

FIG. 1

SIGNAL
INPUT

SPAN : ADJUST THE MAXIMUM READING.
OFFSET : NOT IN SERVICE

SPAN ADJUSTMENT IS ACCESSIBLE BEHIND THE LOW DOOR.

Isolated digital output

(option)

HOLD,

 latch the reading

display, while these pins
are linked

ANALOG OUTPUT
(OPTION)

POWER SUPPLY

see instrument label

½

2

20

200

1.999

19.99

199.9

DISPLAY
READING

DP18-AC1

DP18-AC2

DP18-AC3

DP18-AC4

RANGE
  mAac.

MODEL

2000

1999

DECIMAL POINT
CLOSE JUMPER
          FIG.5

   mA.

RESOLUTION

IMPEDANCE
    R

 in 

D3

D2

D1

-----

221 

22.1 

2.21 

0.187 

0.001

0.01

0.1

1

1650 

R4 value
in 

1580 

RANGE SELECTION

FIG. 3

SIGNAL CONDITIONER

PT1

C

B

A

RS

R4

GROSS SPAN ADJUSTMENT

COMPONENTS VIEW

SIGNAL INPUT
    mAac

SELECT THE DESIRED RANGE, MODIFIYNG THE  RESISTANCE VALUE Rs AND R4, TO GET THE READING DESIRED,

ACCORDING TO THE VALUES SHOWN IN THE TABLE.

AC CURRENT INSTRUMENT, 3 

½

 

 DIGITS, WITH FOUR RANGES SELECTABLE ON THE SIGNAL CONDITIONER BY ONLY MODIFIYNG THE

VALUE OF TWO RESISTORS (SEE TABLE ON FIG.3 ). THE READING CAN NOT BE MODIFIED IN ENGINEERING UNITS UNLESS THE VALUES
OF RS AND R4 ARE CHANGED. THEREFORE USING THE STANDARD VALUES THE DISPLAY WILL SHOW EXACTLY THE VALUE PRESENT

AT THE INPUT SIGNAL.

SPECIFICATIONS

Reviews: