background image

M2216/1201

http://www.omega.com  

e-mail: [email protected]

®

User’s Guide

CCT-05

Frequency Input Signal Conditioners

Summary of Contents for CCT-05 Series

Page 1: ...M2216 1201 http www omega com e mail info omega com User sGuide CCT 05 Frequency Input Signal Conditioners ...

Page 2: ...n France 0800 4 06342 e mail france omega com Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Tel 49 07056 3017 FAX 49 07056 8540 Toll Free in Germany 0130 11 21 66 e mail germany omega com United Kingdom 25 Swannington Road P O Box 7 Omega Drive ISO 9002 Certified Broughton Astley Leicestershire Irlam Manchester LE9 6TU England M44 5EX England Tel 44 1455 285520 Tel 44 161 777 6611...

Page 3: ...he Power Supply 4 Signal Output module MS 5 Changing the Signal Output 5 Signal Input module ME Overview 6 Sensor Type Selection 7 CCT 05 Electrical Features Specifications 7 Signal Input Range Selection 8 Adjustment and Calibration Procedure 8 Connections 9 Mechanical Specifications 10 Notes 11 2 ...

Page 4: ...itioner body into the case the following must be checked The front label blue color must be in its correct position with terminals 1 and 7 power supply separated from the other terminals The three internal modules must be inserted correctly in their internal case guides A C c c d e d FIG 1 B e PROCEDURE FOR DISASSEMBLY 1 Pull out the ME input module towards a 2 Pull out the MS output module toward...

Page 5: ... Contact your local distributor for instructions TABLE 1 Power Fuse supply value 230 Vac 50 mA 115 Vac 100 mA 48 Vac 150 mA 24 Vac 300 mA 24 Vdc 300 mA FIG 3 Fuse Switch Power supply OUTPUTS SALIDAS mA Vdc INPUT ENTRADA S UPPLY ALIM E NTAC ION 3 4 5 6 9 10 11 12 7 1 Lo H i PRECAUTIONS The installation must incorporate safety devices to protect the operator and the process when using the Transmitte...

Page 6: ...d F as shown in Figure 6 Other non standard output voltage and current ranges may be obtained by adding and or replacing resistors given in Tables 2 and 3 R18 R29 R30 R24 R25 R31 R32 E F FIG 6 Replace or add the indicated resistors with the values shown in Tables 2 and 3 for the desired output Output Value in KΩ for in V R29 R30 R31 R32 10 49 9 200 0 to 1 11 100 0 to 5 100 100 1 to 5 100 66 5 100 ...

Page 7: ... of these terminals FIG 7 Solder pads on solder side P1 Output zero adjustment P2 Gain amplifier adjustment P2 P1 6 OFFSET ADJUST Solder pad 1 if closed Adjust the low range level of the output Offset positive coarse Solder pad 2 if closed Adjust the low range level of the output Offset negative coarse Jumper A if closed Adjust the low range level of the output Offset negative fine AMPLIFIER GAIN ...

Page 8: ...0 015 C STANDARD POWER SUPPLY 115 Vac 10 50 60 Hz POWER CONSUMPTION 1 5 VA TEST VOLTAGE 4 kVeff 50 Hz 1m CCT 05 ELECTRICAL FEATURES SENSOR TYPE SELECTION 7 This signal conditioner can connect to standard sensors such as PNP NPN Namur or ac signals See the Connections Section The signal conditioner provides two excitation voltages for the sensors 24 Vdc for PNP or NPN sensors and 8 2 Vdc for NAMUR ...

Page 9: ... a digital multimeter to the signal output terminals 11 and 12 for Voltage output 9 and 10 for Current output 6 Power up the conditioner with the appropriate power supply 7 Adjust the pulse generator until it generates the low signal level 8 Turn the ZERO trimmer P1 located on the ME input module until the multimeter shows the desired low signal output level For example 0 Vdc 9 Adjust the pulse ge...

Page 10: ...T Voltage OUTPUTS SALIDAS mA Vdc INPUT ENTRADA SUPPLY ALIMENTACION 3 4 5 6 9 10 11 12 7 1 Lo H i POWERSUPPLY The side label shows the type and value of the power supply SIGNALOUTPUT Current Sinusoidal frequency 9 SIGNALOUTPUT Voltage SIGNALOUTPUT Current Sensors PNP or NPN OUTPUTS SALIDAS mA Vdc INPUT ENTRADA SUPPLY ALIMENTACION 3 4 5 6 9 10 11 12 7 1 Lo H i POWERSUPPLY The side label shows the ty...

Page 11: ...3 4 5 6 9 10 11 12 7 1 Lo H i TECHNICAL DATA WEIGHT 270 g HOUSING BASE Polycarbonate RAL 7032 UL 94 V 1 light grey IP 40 TERMINAL HOUSING COVER AND BLIND PLUGS Polycarbonate UL 94 V 2 dark grey IP 20 WIRE CROSS SECTION 4 mm2 Provided with a snap fastener for attaching to DIN 46277 and DIN EN 50022 35 x 7 5 mm assembly rails 10 ...

Page 12: ...NOTES 11 ...

Page 13: ...erwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Sh...

Page 14: ...Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industrial pH Conductivity Equipment DATA ACQUISITION M U Data Acquisition Engineering Software M U Communications Based Acquisition Systems M U Plug in Cards for Apple IBM Compatibles M U Datalogging Systems M U Recorders Pr...

Reviews: