Omega Altise OAPC10 User Manual Download Page 1

 
                                                                                              

USER’S MANUAL

 

 

PORTABLE AIR CONDITIONER 

 

 

 

 

 

TECHNICAL SPECIFICATION 

MODEL : 

OAPC10

 

Voltage : 220-240V~ 50Hz      
Power consumption: 890W 

 

 
 
 
 

IMPORTANT SAFEGUARDS 

Summary of Contents for OAPC10

Page 1: ...USER S MANUAL PORTABLE AIR CONDITIONER TECHNICAL SPECIFICATION MODEL OAPC10 Voltage 220 240V 50Hz Power consumption 890W IMPORTANT SAFEGUARDS...

Page 2: ...play with the appliance If the power cord is damaged it must be performed by an authorised agent of Omega Altise SAFETY RULES To prevent injury to the user or other people and to prevent property dama...

Page 3: ...not use this appliance if it is malfunctioning or has been dropped or damaged Never use the power point switch to start or stop the unit Use the control panel first Do not obstruct the inlet or outle...

Page 4: ...clockwise figure 2 Put adapter into window seal plate adjust window open width in order seal plate match window well and the length of seal plate is adjustable FIGURE 2 FIG Installation Errors Free a...

Page 5: ...ten the length as much as possible and keep it level as much as possible when installing Parts List Front side figure 5 1 Handle 2 Control Panel 3 Air outlet 4 Fan blade 5 Castor Rear Side figure 6 3...

Page 6: ...ote control 9 Water Full indicator 10 Indicator for compressor 11 High ventilation indicator 12 Low ventilation indicator 13 Timer operation indicator 14 Display window 15 Sleep operation indicator 16...

Page 7: ...setting temperature from 16 31 under timer mode press this key to downward on off time 5 UP under cooling mode press this key to upward temperature from 16 31 under timer mode press this key to upward...

Page 8: ...n speed Press MODE to select cooling mode cooling mode indictor turns on Press UP or DOWN to adjust temperature from 16 to 31 Press FAN to select high or low fan speed Fan mode Press MODE to select fa...

Page 9: ...de default value of fan speed is low When sleeping mode turns on under cooling mode one hour later temperature will go up 1 from setting temperature and then keep the same under heating mode one hour...

Page 10: ...pliance before cleaning Cleaning Please switch off at the control panel then at the power point then unplug before cleaning Use soft semi dry cloth to clean the machine Don t use chemical agents such...

Page 11: ...tion Power off Power on P2 flashes on screen or water full indicator turns on Drain water out Machine cannot work Timer off turns on Turn off machine for three minutes then restart it Direct sunlight...

Page 12: ...acity BTU h 10000 Mains 220 240V 50Hz 1Ph Power consumption W 890 Current A 3 95 Dehumidification L 24h 24 Refrigerant R410A Compressor Rotary Fan speeds 2 Thermostat 16 31 Timer h 0 24 Dimensions W H...

Reviews: