Installation and Operating
Manual
(EMD12)
Page 1: ...3400598 EMD12_v2 01 OmegaAir_eng Installation and Operating Manual EMD12...
Page 2: ...ainer where solid parts of debris are intercepted The strainer is located in front of EMD12 so that it could be reached easily In the condensed water leaving the EMD12 there are still small particles...
Page 3: ...er open In the timed venting mode the valve is opened after the venting period has expired and trapped air is allowed to escape through drainage Now condensed water can reach water level sensor and EM...
Page 4: ...er tank 7 8 9 Sealing O Ring 14 x 2 0 10 Service Network Connector 11 Screw M3x16 DIN912 12 Washer 3 2 DIN125A 13 Cover 14 Sealing O Ring 100 x 1 5 15 Power Inlet gland 16 Washer 5 3 DIN125A 17 Washer...
Page 5: ...10VA 8 5W Operating pressure range 0 16 bar 0 232 psi 0 8 bar 0 116 psi Drain capacity 7 bar 101 psi 12 l h 0 007 cfm Operating temperature range 1 5 C 65 C Protection class 54 Inlet connection G 1 2...
Page 6: ...n and maintenance work may only be carried out when electrical power supply is disconnected Electrical work must always be carried out by qualified electrician Do not exceed maximal operating pressure...
Page 7: ...horizontally left or vertically right But it must not be rolled aside more than 15 The horizontal position is preferred in case of a lot of debris in condensed water Do not connect several condensed w...
Page 8: ...gh auxiliary inlet EMD12 has provisions for building an auxiliary inlet where venting could be connected This auxuliary inlet is not implemented in the standard EMD12 Conntact manufacturer for more in...
Page 9: ...dance 200mA U reverse 0 7V Power Connection 1 24Vac grounded line 2 24Vac 3 PE Conductor Valve Connection 4 PE Conductor 5 Power line 6 Power line Alarm output EMD12A 7 Alarm Warning 9 GND Umax at hig...
Page 10: ...nect EMD12 after protection device of heavy inductive load like compressor motor left Instead heavy inductive load and EMD12 should be protected separately right After installation or maintenance work...
Page 11: ...mode In this mode EMD12 opens its valve longer and more frequently and its capacity is doubled When EMD12 is still not able to discharge all the water in 5min it enters alarm mode In alarm mode EMD12...
Page 12: ...device could be a Service Network Reader SN 10 200 It s a handheld device that allows user to send command messages manually It also comprises a display where answer to command are read In the table i...
Page 13: ...eset counter 0xBC Water level sensor adjustment data 0xC0 Current working parameters 0xE0 0xF0 Settings 0xE4 Timed Venting valve opened period Values 0 6s 0 8s 1 2s 1 7s 2 4s Timed venting off default...
Page 14: ...insert and clean it At the same time check integrity of mesh Be careful while cleaning because solid particles in debris may be sharp Clean also O ring sealing and its gland thoroughly Otherwise stra...
Page 15: ...isible damage on electronics Air leaks through the drain pipe even when EMD is disconnected from power There might be debris in valve or valve may be damaged Check integrity of strainer The valve asse...
Page 16: ...installation and operating manual was not followed with respect to installation initial commissioning and maintenance The unit was not operated properly and appropriately The unit was operated when i...