background image

ECDh-5 - Installation and operating manual 

www.omega-air.si 

 

Installation 

 

 

Part 

1  Heating element 
2  ECD housing (not included) 
3  Junction surface 
4  Self tapping screws M5 DIN7500 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for ECDh-5

Page 1: ...stallation and operating manual ECDh 5 Please read the following instructions carefully before installing heater into service Trouble free and safe operating of the unit can only be guaranteed if reco...

Page 2: ...y qualified electrician Installation and maintenance work may only be carried out when the device is not connected to power supply Do not exceed max operating temperature range or operating voltage se...

Page 3: ...Dh heater installed on bare ECD meaning ECD drain was not connected to any piping system and there was no condensate flow through housing When dimensioning and installing condensate drain and heater i...

Page 4: ...ECDh 5 Installation and operating manual 4 www omega air si Detailed temperature response measured between inside connection pipe T1 and ambient T2 is shown on graph...

Page 5: ...ECDh 5 Installation and operating manual www omega air si 5 Installation Part 1 Heating element 2 ECD housing not included 3 Junction surface 4 Self tapping screws M5 DIN7500 1 2 3 4...

Page 6: ...t cable to the mains voltage supply Make sure the power is turned off before proceeding Ensure proper insulation in the power socket Maintenance Service It is recommended to check the connecting cable...

Page 7: ...ermal insulation to the heater and inlet and outlet piping Heater is not connected to power supply Ensure the proper electrical connection Warranty exclusion The guarantee shall be void if The install...

Page 8: ...OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia Tel 386 0 1 200 68 00 Fax 386 0 1 200 68 50 E mail info omega air si www omega air si 8 www omega air si...

Reviews: