10
Maintenance
Troubleshooting
If servicing operations require repairs to electrical system and/or replacement of bearings or mechanical
components, call an expert technician or your local dealer.
MACHINE WHIRR
The whirring noise emitted by the machine has been measured on an identical sample machine in compliance
with standard DIN 45635. A constant value not exceeding 70_dB(A) was measured as stated in the
manufacturer’s test report.
DISMANTLING AND DEMOLISHING THE MACHINE
If machine needs to be dismantled and/or demolished, its components do not entail a degree of danger that
requires any particular precaution. Remember, however, that to facilitate material recycling operations, it is a
good rule to remove electrical system components from the machine.
PROBLEMS
CAUSES
REMEDIES
Machine operation failure.
Disconnected plug.
Connect plug.
Plug leads not correctly connected.
Check lead connections.
Trip switch adjusted for insufficient
values.
Adjust trip switch accordingly.
Unsuitable trip switch.
Replace trip switch.
The security hook on the pool
cover is not inserted properly.
Position the hook at the end of the
run.
The product gets stuck when being
poured out.
Dough too humid is used.
Reduce the quantity of water
used for the dough respecting the
abovementioned percentage.
The product looks unacceptable
even after the initial minutes: it
breaks and looses flour.
Too short kneading time.
Increase the kneading time.
Too reduced water percentage.
Increase the quantity of
water in order to respect the
aforementioned percentage.
The product does not come out
from the drawplate.
The blocking of the drawplate
because of dried dough.
Disassemble and clean the
drawplate.