Siemens V20_EN_rev01-08032019.docx
9-4
9.2.2
Viewing inverter status
The display menu provides a basic monitoring view of some key parameters such as frequency, voltage,
current, and so on
.
9.2.3
Editing of parameters
This section explains how to edit the parameters.
Some parameters are indexed because contain more values inside them.
Normal editing of parameters
Note:
Pressing
▲ or ▼ for longer than two seconds to quickly increase or decrease the parameter numbers
or indexes is only possible in the parameter menu.
This editing method is best suited when small changes are required to parameter numbers, indexes, or val-
ues.
To increase or decrease the parameter number, index, or value, press
▲
or
▼
for less than two
seconds.
To quickly increase or decrease the parameter number, index, or value, press
▲ or ▼ for longer
than two seconds.
To confirm the setting, press OK
To cancel the setting, press M
Digit-by-digit editing
Note:
Digit-by-digit editing of parameter numbers or indexes is only possible in the parameter menu.
Digit-by-digit editing can be performed on parameter numbers, parameter indexes, or parameter values. This
editing method is best suited when large changes are required to parameter numbers, indexes, or values.
In any edit or scroll mode, digit-by-digit editing is entered by a long press (> 2 s) on OK .
The digit-by-digit editing always starts with the rightmost digit.
Each digit is selected in turn by pressing OK .