Page 1: ...PT 056 Instruction Manual PT 056 2013 Printed in China WC403101 2014 2 http www olympus com PT 056_1 4 fm 1...

Page 2: ...hall in no way be responsible for accidents involving immersion of a digital camera in water In addition expenses incurred for damage of internal materials or loss of recorded contents due to water en...

Page 3: ...2 Do not store with a battery in the digital camera housed in this product Storage with a battery inserted may lead to leakage of the battery liquid and fire 3 If leakage of water should occur with a...

Page 4: ...with high temperature and humidity or with severe temperature changes Locations with volatile substances 3 Opening and closing at locations with much sand dust or dirt may impair the waterproof charac...

Page 5: ...Case after taking pictures in the water it may cause the loss of transparency of the lens inside even if you insert the supplied silica gel to the Case when drying the camera is insufficient Chemical...

Page 6: ...before use 15 Remove the O ring 15 Remove any sand dirt etc 16 How to Apply Grease to the O ring 17 Install the O ring 18 3 Install the digital camera 19 Open the Case 19 Load the digital camera 20 Ma...

Page 7: ...Function 27 Remove the O ring 27 Remove any sand dirt etc 27 How to Apply Grease to the O ring 27 Install the O ring 27 Replace consumable parts 27 7 Appendix 28 Specifications 28 PT 056_EN book Page...

Page 8: ...ccessories are missing or damaged O ring remover Hand strap Lens cap Silica gel 1g Silicone grease Instruction manual this manual Case body Check that the O ring is installed LCD hood on the body LCD...

Page 9: ...m grip 2 Zoom Lever 3 Shutter lever 4 ON OFF button 5 Front lid 6 Accessory mount 7 Diffuser 8 Open close dial 9 Lock knob 0 Lens ring a LCD inner hood b O ring c Tripod seat PT 056_EN book Page 9 Thu...

Page 10: ...on k button arrow pad T l MENU Wi Fi button m Arrow pad W n LCD monitor window o Rear lid Memo The Case operation parts marked by corresponds to the operation parts of the digital camera When the oper...

Page 11: ...the Case body How to use the hand strap Pass your hand through the hand strap and adjust the length with the stop button Hand strap ring Hand strap Installation illustration Installation completed st...

Page 12: ...r the other Removal Remove the LCD hood from the guides above and below the LCD monitor window one after the other by widening the LCD hood Mounting and removing the lens cap Fit the lens cap onto the...

Page 13: ...n in the figure below 2 Put the underwater optical fiber cable plug all the way into the optical cable insertion slot of the adapter until the black axis of the connector is hidden Remove the underwat...

Page 14: ...t removing the strap the strap may get caught between the Case lids and may cause water leakage Attach the antireflective ring to the digital camera Remove the lens ring from the digital camera then a...

Page 15: ...ntenance status etc the waterproof function may be damaged Before using always perform the following advance checks Remove the O ring 1 Insert the O ring remover into the gap between the O ring and O...

Page 16: ...swab Also remove any sand or dirt adhered to the O ring contact surface on the front lid of the case CAUTION When a sharp object is used to remove the O ring or to clean the inside of the O ring groov...

Page 17: ...or unevenness After spreading the lubricant check visually and by touch that the O ring is not scratched and that its surface is flat If it is damaged in any way be sure to replace it with a brand ne...

Page 18: ...out from the groove When sealing this product make sure that no hairs fibers sand particles or other foreign matter stick not only to the O ring but also to the contact surface front cover Even a sin...

Page 19: ...re below and turn the open close dial counter clockwise 3 of figure below 3 Turn the open close dial to the position where it cannot be turned further 4 Open the rear lid of the Case gently CAUTION Do...

Page 20: ...efore sealing the Case Is the digital camera loaded properly Is silica gel inserted all the way at the specified location Is the O ring attached properly to the opening on the Case Is there any dirt o...

Page 21: ...he ON OFF button on the Case and confirm that the camera turns ON OFF Press the shutter lever on the Case and confirm that the camera shutter releases Also operate other control buttons on the Case an...

Page 22: ...t no water enters the Case Next immerse the Case for 30 seconds and check that no water drop etc to the Case Then immerse the Case for 3 minutes operate all buttons and levers and check the following...

Page 23: ...ally designed to work without the flash it can also be enabled if required for example when shooting a manta ray HUnderwater Macro Suitable for close up shooting of small fish and other underwater cre...

Page 24: ...When the Underwater Wide Angle 1 or Underwater Macro mode is selected you can easily lock the focus position AF lock operation by pressing the OK AFL button on the rear of the protector When the focus...

Page 25: ...pure water Wipe off any waterdrop Remove any drops of water from the case Use air or a soft cloth not leaving any fibers to thoroughly wipe any waterdrop from the joint between the front and rear lid...

Page 26: ...drip from your hair or body onto the Case and the camera Before opening the Case make sure that your hands or gloves are free of sand fibers etc Do not open or close the Case at locations where there...

Page 27: ...to P 17 Install the O ring Refer to P 18 Replace consumable parts The O ring is a consumable product Independent of the number of times the Case is used it is recommended that the O ring should be rep...

Page 28: ...ries can be purchased Compatible models Olympus digital camera STYLUS TG 3 Pressure resistance Depth of up to 45 m Main materials Body Polycarbonate Lens window Multiple coat glass Diameter of lens ri...

Page 29: ...er flash UFL 1 UFL 2 Short arm PTSA 02 PTSA 03 Step up ring 52mm to 67mm PSUR 03 Underwater wide conversion lens PTWC 01 Underwater macro conversion lens PTMC 01 Maintenance kit PMS 02 O ring remover...