background image

PT
-053

    
  Ins

tr

u

c

tion M

a

nual

 

PT-053

©2012 
Printed in China

http://www.olympus.com/

 

VM364001

PT-053_1-4.fm  1 ページ  2012年3月27日 火曜日 午後6時35分

Summary of Contents for PT-053

Page 1: ...PT 053 Instruction Manual PT 053 2012 Printed in China http www olympus com VM364001 PT 053_1 4 fm 1...

Page 2: ...nance and storage after use zOLYMPUS IMAGING CORP shall in no way be responsible for accidents involving immersion of a digital camera in water In addition expenses incurred for damage of internal mat...

Page 3: ...with a battery in the digital camera housed in this product Storage with a battery inserted may lead to leakage of the battery liquid and fire 3 If leakage of water should occur with a camera install...

Page 4: ...ons subject to vibrations Locations with high temperature and humidity or with severe temperature changes Locations with volatile substances 3 Opening and closing at locations with much sand dust or d...

Page 5: ...Case after taking pictures in the water it may cause the loss of transparency of the lens inside even if you insert the supplied silica gel to the Case when drying the camera is insufficient Chemical...

Page 6: ...e antireflective ring to the digital camera 15 Open the Case 16 Load the digital camera 17 Make sure the camera is loaded properly 17 Seal the Case 18 Check the operation of the loaded camera 18 Perfo...

Page 7: ...7 EN Remove any sand dirt etc 24 How to Apply Grease to the O ring 26 Install the O ring 27 Replace consumable parts 27 7 Appendix 28 Specifications 28 PT 053_EN book Page 7 Monday March 26 2012 11 46...

Page 8: ...accessories are missing or damaged O ring remover Hand strap Lens cap Silica gel 1g Silicone grease Instruction manual this manual Case body Check that the O ring is installed LCD hood on the body LC...

Page 9: ...Palm grip 2 Shutter lever 3 ON OFF button 4 Front lid 5 Accessory mount 6 Diffuser 7 Open close dial 8 Lens ring 9 LCD inner hood 0 O ring a Tripod seat 9 0 a 2 3 4 6 7 8 1 5 PT 053_EN book Page 9 Mo...

Page 10: ...arrow pad T j MENU button k Arrow pad W l LCD monitor window m Rear lid Memo The Case operation parts marked by corresponds to the operation parts of the digital camera When the operation parts of th...

Page 11: ...on the Case body How to use the hand strap Pass your hand through the hand strap and adjust the length with the stop button Hand strap ring Hand strap Installation illustration Installation completed...

Page 12: ...the other Removal Remove the LCD hood from the guides above and below the LCD monitor window one after the other by widening the LCD hood Mounting and removing the lens cap Fit the lens cap onto the l...

Page 13: ...r to the diffuser shown in the figure below 2 Put the underwater optical fiber cable plug all the way into the optical fiber cable optional PTCB E02 insertion slot Remove the underwater optical fiber...

Page 14: ...hat there is no water leakage We recommend to immerse the empty Case to the intended water depth however if you cannot perform this way check the Case by referring Water Leakage Test P 19 2 Main cause...

Page 15: ...aining Number of Pictures to be Taken Confirm that the image storage has a sufficient remaining number of pictures to be taken 3 Remove the hand strap from the digital camera When a digital camera is...

Page 16: ...when using the underwater wide conversion lens PTWC 01 Press the MENU button then select PTWC 01 under Accessory Settings in the Camera Menu 2 Then press the OK button Even if the setting has been ch...

Page 17: ...ca gel inserted all the way at the specified location Is the O ring attached properly to the opening on the Case Is there any dirt or foreign matter on the O ring or the O ring contact surface on the...

Page 18: ...he Case and confirm that the camera turns ON OFF 2 Press the shutter lever on the Case and confirm that the camera shutter releases Also operate other control buttons on the Case and confirm that the...

Page 19: ...rst immerse the Case for only 3 seconds and check that no water drop etc to the Case Next immerse the Case for 30 seconds and check that no water drop etc to the Case Then immerse the Case for 3 minut...

Page 20: ...was originally designed to work without the flash it can also be enabled if required for example when shooting a manta ray HUnderwater Macro Suitable for close up shooting of small fish and other und...

Page 21: ...on When the Underwater Wide Angle 1 or Underwater Macro mode is selected you can easily lock the focus position AF lock operation by pressing the OK AFL button on the rear of the protector When the fo...

Page 22: ...air or a soft cloth not leaving any fibers to thoroughly wipe any waterdrop from the joint between the front and rear lid the palm grip the open close dial and other operating parts CAUTION When water...

Page 23: ...ra Before opening the Case make sure that your hands or gloves are free of sand fibers etc Do not open or close the Case at locations where there is water spray or sand Take care not to touch the digi...

Page 24: ...the tip of the inserted O ring remover below the O ring Be careful not to scratch the O ring groove with the tip of the O ring remover 3 Hold the O ring with your fingertips after it has come out of t...

Page 25: ...his product underwater for the first time When a sharp object is used to remove the O ring or to clean the inside of the O ring groove the Case and the O ring may be damaged and water leakage may occu...

Page 26: ...nd by touch that the O ring is not scratched and that its surface is flat If it is damaged in any way be sure to replace it with a brand new O ring 4 Apply lubricant on the O ring contact surface Use...

Page 27: ...pecial care Replace consumable parts The O ring is a consumable part Regardless of the number of times the Case is used it is recommended that the O ring be replaced with a new one at least once a yea...

Page 28: ...adapter PFCA 02 Antireflective ring POSR 053 The above accessories can be purchased Compatible models Olympus digital camera TOUGH TG 1 Pressure resistance Depth of up to 45 m Main materials Body Pol...

Page 29: ...ater flash UFL 1 UFL 2 Short arm PTSA 02 PTSA 03 Step up ring 52mm to 67mm PSUR 03 Underwater wide conversion lens PTWC 01 Underwater macro conversion lens PTMC 01 Maintenance kit PMS 02 O ring remove...

Page 30: ...PT 053_EN book Page 30 Monday March 26 2012 11 46 AM...

Page 31: ...PT 053 Instruction Manual PT 053 2012 Printed in China http www olympus com VM364001 PT 053_1 4 fm 1...

Reviews: