background image

EPOCH 650 — Getting Started Guide

1

 

Intended Use

The EPOCH 650 ultrasonic flaw detector is designed to perform nondestructive inspections of 
industrial and commercial materials. Do not use the EPOCH 650 for any purpose other than its 
intended use.

Instruction Manual

Before use, thoroughly review the 

EPOCH 650 Ultrasonic Flaw Detector User’s Manual

. Use the product 

as instructed. The 

User’s Manual

 contains essential information on how to use this Olympus product 

safely and effectively. Keep the 

User’s Manual

 in a safe, accessible location.

Safety Signal Words

Indicates an imminently hazardous situation and calls attention to a procedure, practice, or the like, 
which, if not correctly performed or adhered to, will result in death or serious personal injury

Indicates a potentially hazardous situation and calls attention to a procedure, practice, or the like, 
which, if not correctly performed or adhered to, could result in death or serious personal injury.

Indicates a potentially hazardous situation and calls attention to a procedure, practice, or the like, 
which, if not correctly performed or adhered to, may result in minor or moderate personal injury, 
material damage, particularly to the product, destruction of part or all of the product, or loss of data.

DANGER

WARNING

CAUTION

EPOCH 650 Ultrasonic Flaw Detector
Getting Started Guide

Summary of Contents for EPOCH 650

Page 1: ...ates an imminently hazardous situation and calls attention to a procedure practice or the like which if not correctly performed or adhered to will result in death or serious personal injury Indicates a potentially hazardous situation and calls attention to a procedure practice or the like which if not correctly performed or adhered to could result in death or serious personal injury Indicates a po...

Page 2: ...rted Guide P N DMTA 10056 01EN Q7780001 6 EPOCH 650 Ultrasonic Flaw Detector User s Manual P N EP650 MANUAL CD Q7780010 on CD ROM 7 USB cable P N EPLTC C USB A 6 U8840031 USB cable not shown Connections To avoid the risk of electric shock do not touch the inner conductor of the BNC or LEMO connectors Up to 400 V can be present on the inner conductors The warning symbol shown above warns of this el...

Page 3: ... EPOCH 650 charger adaptor P N EP MCA X is designed to power the EPOCH 650 and charge the batteries only P N 600 BAT L 3 U8051431 Do not attempt to power or charge other electronic equipment with the EP MCA charger adaptor as doing so could create an explosion resulting in death or serious personal injury Do not insert any other type of battery into the battery compartment or use any other type of...

Page 4: ...e instrument 7 Tighten the two thumb screws to complete the installation To Install the microSD Card 1 Remove the microSD card from its packaging 2 Loosen the two thumb screws and open the EPOCH 650 side door 3 Hold the microSD card so that the metal pins face toward the front of the instrument 4 Gently slide the card into the microSD slot until it clicks To remove the microSD card gently push the...

Page 5: ...key is used to navigate through menus and setup pages The arrow keys navigation pad version or the adjustment knob adjustment knob version are used to select and change parameter values The label on each key indicates its primary function Labels located at the top of or above direct access keys indicate a secondary key function The 2ND F key must be pressed before the secondary function can be act...

Page 6: ... Interface Arrow keys Check and Escape keys Direct access keys Direct access keys NEXT FULL key English International Chinese Japanese Arrow keys Check and Escape keys Direct access keys Direct access keys NEXT FULL key Function keys Parameter keys ...

Page 7: ...p is identified by a number 1 5 2 5 3 5 4 5 and 5 5 To scroll through the menu groups use the NEXT key Live A scan view Measurement readings up to 5 Parameter buttons Menu buttons Basic parameters Gate 2 blue Gate 1 red Group menu identification number File ID number File name NEXT key 1 5 2 5 3 5 4 5 5 5 ...

Page 8: ...REEZE is active Gate 1 is in edge measurement mode PEAK MEM is active Gate 2 is in edge measurement mode 2nd F PEAK HOLD is active Gate 1 is in first peak measurement mode Indicates that waveform averaging is active Gate 2 is in first peak measurement mode Access to all instrument functions except On Off is locked Gate 1 is in J Flank measurement mode Indicates that a microSD card is installed Gat...

Page 9: ... of extreme heat Exposing batteries to extreme heat over 80 C could result in an explosion or personal injury Do not drop hit or otherwise abuse a battery as doing so could expose the cell contents which are corrosive and explosive Do not short circuit the battery terminals A short circuit could cause injury and severe damage to a battery making it unusable Do not expose a battery to moisture or r...

Page 10: ......

Page 11: ......

Page 12: ...Olympus All rights reserved The microSD logo is a trademark of SD 3C LLC All brands are trademarks or registered trademarks of their respective owners and third party entities Part ID Q7780001 Q7780001 Printed on Rolland Hitech50 which contains 50 post consumer fiber DMTA 10056 01EN Rev A February 2015 DMTA 10056 01EN 50 EPOCH 650 Getting Started Guide ...

Reviews: